BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

1149 related articles for article (PubMed ID: 17937322)

  • 1. [Active clinical surveillance for detection of Legionnaires' disease: implications for health care structures].
    Marchesi I; Bargellini A; Cencetti S; Marchegiano P; Cauteruccio L; Casolari C; Borella P
    Ann Ig; 2007; 19(4):295-302. PubMed ID: 17937322
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A recurrent outbreak of nosocomial legionnaires' disease detected by urinary antigen testing: evidence for long-term colonization of a hospital plumbing system.
    Lepine LA; Jernigan DB; Butler JC; Pruckler JM; Benson RF; Kim G; Hadler JL; Cartter ML; Fields BS
    Infect Control Hosp Epidemiol; 1998 Dec; 19(12):905-10. PubMed ID: 9872526
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Control of nosocomial Legionnaires' disease by keeping the circulating hot water temperature above 55 degrees C: experience from a 10-year surveillance programme in a district general hospital.
    Darelid J; Löfgren S; Malmvall BE
    J Hosp Infect; 2002 Mar; 50(3):213-9. PubMed ID: 11886198
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Detecting legionellosis by unselected culture of respiratory tract secretions and developing links to hospital water strains.
    Köhler JR; Maiwald M; Lück PC; Helbig JH; Hingst V; Sonntag HG
    J Hosp Infect; 1999 Apr; 41(4):301-11. PubMed ID: 10392336
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Point-of-care controls for nosocomial legionellosis combined with chlorine dioxide potable water decontamination: a two-year survey at a Welsh teaching hospital.
    Hosein IK; Hill DW; Tan TY; Butchart EG; Wilson K; Finlay G; Burge S; Ribeiro CD
    J Hosp Infect; 2005 Oct; 61(2):100-6. PubMed ID: 16002178
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Legionellosis in Apulia (Italy): an underevaluated disease].
    Montagna MT; Napoli C; Tatò D; Spilotros G; Como D; Barbuti S
    Ann Ig; 2005; 17(1):3-9. PubMed ID: 15869165
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Nosocomial legionnaires' disease discovered in community hospitals following cultures of the water system: seek and ye shall find.
    Goetz AM; Stout JE; Jacobs SL; Fisher MA; Ponzer RE; Drenning S; Yu VL
    Am J Infect Control; 1998 Feb; 26(1):8-11. PubMed ID: 9503106
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Cold tap water as a source of fatal nosocomial pneumonia due to Legionella pneumophila in a rehabilitation center].
    Hoebe CJ; Cluitmans JJ; Wagenvoort JH; van Leeuwen WJ; Bilkert-Mooiman MA
    Ned Tijdschr Geneeskd; 1999 May; 143(20):1041-5. PubMed ID: 10368731
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Outbreak of hospital acquired Legionnaires' disease in patients of ophthalmic ward. Nosocomial Legionella infections for the first time observed in Poland].
    Stypułkowska-Misiurewicz H; Pancer K; Krogulska B; Matuszewska R
    Przegl Epidemiol; 2007; 61(4):657-65. PubMed ID: 18572497
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Prevention and control of Legionella infection in the hospital environment].
    Borella P; Bargellini A; Pergolizzi S; Aggazzotti G; Curti C; Nizzero P; Stancanelli G; Vaiani R; Gesù G; Mazzuconi R
    Ann Ig; 2000; 12(4):287-96. PubMed ID: 11140095
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Legionnaires' disease on a cruise ship linked to the water supply system: clinical and public health implications.
    Castellani Pastoris M; Lo Monaco R; Goldoni P; Mentore B; Balestra G; Ciceroni L; Visca P
    Clin Infect Dis; 1999 Jan; 28(1):33-8. PubMed ID: 10028067
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Prospective 3-year surveillance for nosocomial and environmental Legionella pneumophila: implications for infection control.
    Boccia S; Laurenti P; Borella P; Moscato U; Capalbo G; Cambieri A; Amore R; Quaranta G; Boninti F; Orsini M; Branca G; Fadda G; Romano-Spica V; Ricciardi G
    Infect Control Hosp Epidemiol; 2006 May; 27(5):459-65. PubMed ID: 16671026
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Legionella contamination in the hospital environment: monitoring of the hot water distribution systems of three hospitals in Catania (Italy)].
    Pignato S; Coniglio MA; Faro G; Cantaro P; Carini SA; Mangano G; Cunsolo R; Coco G; Giammanco G
    Ig Sanita Pubbl; 2006; 62(6):635-52. PubMed ID: 17256019
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Community-acquired pneumonia due to Legionella pneumophila serogroup 1. Study of 97 cases].
    Benito JR; Montejo JM; Cancelo L; Zalacaín R; López L; Fernández Gil de Pareja J; Alonso E; Oñate J
    Enferm Infecc Microbiol Clin; 2003 Oct; 21(8):394-400. PubMed ID: 14525703
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Legionnaires' disease surveillance: England and Wales, 1991.
    Watson JM; Bezzant M
    Commun Dis Rep CDR Rev; 1992 Oct; 2(11):R130-1. PubMed ID: 1284933
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Clinical and environmental distribution of Legionella pneumophila in a university hospital in Italy: efficacy of ultraviolet disinfection.
    Triassi M; Di Popolo A; Ribera D'Alcalà G; Albanese Z; Cuccurullo S; Montegrosso S; Crispino M; Borella P; Zarrilli R
    J Hosp Infect; 2006 Apr; 62(4):494-501. PubMed ID: 16455159
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Epidemiological investigation of a case of nosocomial Legionnaires' disease in Taiwan: implications for routine environmental surveillance.
    Chien ST; Hsueh JC; Lin HH; Shih HY; Lee TM; Ben RJ; Chou ST; Fong CM; Lin YE; Tseng LR; Chiang CS
    Clin Microbiol Infect; 2010 Jun; 16(6):761-3. PubMed ID: 19624501
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Efficacy of point-of-entry copper--silver ionisation system in eradicating Legionella pneumophila in a tropical tertiary care hospital: implications for hospitals contaminated with Legionella in both hot and cold water.
    Chen YS; Lin YE; Liu YC; Huang WK; Shih HY; Wann SR; Lee SS; Tsai HC; Li CH; Chao HL; Ke CM; Lu HH; Chang CL
    J Hosp Infect; 2008 Feb; 68(2):152-8. PubMed ID: 18192074
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Hospital characteristics associated with colonization of water systems by Legionella and risk of nosocomial legionnaires' disease: a cohort study of 15 hospitals.
    Kool JL; Bergmire-Sweat D; Butler JC; Brown EW; Peabody DJ; Massi DS; Carpenter JC; Pruckler JM; Benson RF; Fields BS
    Infect Control Hosp Epidemiol; 1999 Dec; 20(12):798-805. PubMed ID: 10614602
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Legionnaire's disease: a nosocomial outbreak in Turkey.
    Ozerol IH; Bayraktar M; Cizmeci Z; Durmaz R; Akbas E; Yildirim Z; Yologlu S
    J Hosp Infect; 2006 Jan; 62(1):50-7. PubMed ID: 16198023
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 58.