BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

176 related articles for article (PubMed ID: 17943446)

  • 1. Volume dependence of high-frequency respiratory mechanics in healthy adults.
    Thamrin C; Finucane KE; Singh B; Hantos Z; Sly PD
    Ann Biomed Eng; 2008 Jan; 36(1):162-70. PubMed ID: 17943446
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Measurement of changes in respiratory mechanics during partial liquid ventilation using jet pulses.
    Schmalisch G; Schmidt M; Proquitté H; Foitzik B; Rüdiger M; Wauer RR
    Crit Care Med; 2003 May; 31(5):1435-41. PubMed ID: 12771615
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effects of tidal volume and methacholine on low-frequency total respiratory impedance in dogs.
    Lutchen KR; Jackson AC
    J Appl Physiol (1985); 1990 May; 68(5):2128-38. PubMed ID: 2193908
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Tracking variations in airway caliber by using total respiratory vs. airway resistance in healthy and asthmatic subjects.
    Black LD; Dellaca R; Jung K; Atileh H; Israel E; Ingenito EP; Lutchen KR
    J Appl Physiol (1985); 2003 Aug; 95(2):511-8. PubMed ID: 12692146
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Broadband frequency dependence of respiratory impedance in rats.
    Thamrin C; Sly PD; Hantos Z
    J Appl Physiol (1985); 2005 Oct; 99(4):1364-71. PubMed ID: 15932962
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Interpretation of respiratory input impedance in healthy infants.
    Jackson AC; Neff KM; Dorkin HL; Lutchen KR
    Pediatr Pulmonol; 1996 Dec; 22(6):364-75. PubMed ID: 9016470
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Physiological basis for resonant frequencies in respiratory system impedances in dogs.
    Jackson AC; Lutchen KR
    J Appl Physiol (1985); 1991 Mar; 70(3):1051-8. PubMed ID: 2032970
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Lung volume recruitment maneuvers and respiratory system mechanics in mechanically ventilated mice.
    Cannizzaro V; Berry LJ; Nicholls PK; Zosky GR; Turner DJ; Hantos Z; Sly PD
    Respir Physiol Neurobiol; 2009 Dec; 169(3):243-51. PubMed ID: 19788941
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Low-frequency assessment of airway and tissue mechanics in ventilated COPD patients.
    Lorx A; Szabó B; Hercsuth M; Pénzes I; Hantos Z
    J Appl Physiol (1985); 2009 Dec; 107(6):1884-92. PubMed ID: 19833812
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Lung stress and strain during mechanical ventilation for acute respiratory distress syndrome.
    Chiumello D; Carlesso E; Cadringher P; Caironi P; Valenza F; Polli F; Tallarini F; Cozzi P; Cressoni M; Colombo A; Marini JJ; Gattinoni L
    Am J Respir Crit Care Med; 2008 Aug; 178(4):346-55. PubMed ID: 18451319
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Airway and respiratory tissue mechanics in normal infants.
    Hall GL; Hantos Z; Peták F; Wildhaber JH; Tiller K; Burton PR; Sly PD
    Am J Respir Crit Care Med; 2000 Oct; 162(4 Pt 1):1397-402. PubMed ID: 11029351
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Partitioning of airway and respiratory tissue mechanical impedances by body plethysmography.
    Peslin R; Duvivier C
    J Appl Physiol (1985); 1998 Feb; 84(2):553-61. PubMed ID: 9475865
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Respiratory input impedance from 4 to 256 Hz in normals and chronic airflow obstruction: comparisons and correlations with spirometry.
    Chalker RB; Celli BR; Habib RH; Jackson AC
    Am Rev Respir Dis; 1992 Sep; 146(3):570-6. PubMed ID: 1519830
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Respiratory input impedance up to 256 Hz in healthy humans breathing foreign gases.
    Rotger M; Farré R; Navajas D; Peslin R
    J Appl Physiol (1985); 1993 Jul; 75(1):307-20. PubMed ID: 8376280
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Volume dependence of respiratory impedance in infants.
    Peták F; Hayden MJ; Hantos Z; Sly PD
    Am J Respir Crit Care Med; 1997 Oct; 156(4 Pt 1):1172-7. PubMed ID: 9351618
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Low-frequency respiratory mechanics using ventilator-driven forced oscillations.
    Lutchen KR; Kaczka DW; Suki B; Barnas G; Cevenini G; Barbini P
    J Appl Physiol (1985); 1993 Dec; 75(6):2549-60. PubMed ID: 8125874
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Input respiratory impedance measured by head generator in preschool children.
    Mazurek H; Willim G; Marchal F; Haluszka J; Tomalak W
    Pediatr Pulmonol; 2000 Jul; 30(1):47-55. PubMed ID: 10862162
    [TBL] [Abstract][Full Text] [Related]  

  • 18. High-frequency respiratory impedance measured by forced-oscillation technique in infants.
    Frey U; Silverman M; Kraemer R; Jackson AC
    Am J Respir Crit Care Med; 1998 Aug; 158(2):363-70. PubMed ID: 9700108
    [TBL] [Abstract][Full Text] [Related]  

  • 19. High tidal volume ventilation is not deleterious in infant rats exposed to severe hemorrhage.
    Cannizzaro V; Berry LJ; Nicholls PK; Hantos Z; Sly PD
    J Trauma; 2010 Oct; 69(4):E24-31. PubMed ID: 20495489
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Negative impact of the noseclip on high-frequency respiratory impedance measurements.
    Thamrin C; Albu G; Sly PD; Hantos Z
    Respir Physiol Neurobiol; 2009 Jan; 165(1):115-8. PubMed ID: 19010453
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.