These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

125 related articles for article (PubMed ID: 17945602)

  • 1. Optical dialysis adequacy sensor: contribution of chromophores to the ultra violet absorbance in the spent dialysate.
    Lauri K; Tanner R; Luman M; Jerotskaja J; Fridolin I
    Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():807-10. PubMed ID: 17945602
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Optical dialysis adequacy sensor: wavelength dependence of the ultra violet absorbance in the spent dialysate to the removed solutes.
    Jerotskaja J; Lauri K; Tanner R; Luman M; Fridolin I
    Annu Int Conf IEEE Eng Med Biol Soc; 2007; 2007():2960-3. PubMed ID: 18002616
    [TBL] [Abstract][Full Text] [Related]  

  • 3. HPLC study of uremic fluids related to optical dialysis adequacy monitoring.
    Lauri K; Tanner R; Jerotskaja J; Luman M; Fridolin I
    Int J Artif Organs; 2010 Feb; 33(2):96-104. PubMed ID: 20306436
    [TBL] [Abstract][Full Text] [Related]  

  • 4. On-line monitoring of solutes in dialysate using absorption of ultraviolet radiation: technique description.
    Fridolin I; Magnusson M; Lindberg LG
    Int J Artif Organs; 2002 Aug; 25(8):748-61. PubMed ID: 12296459
    [TBL] [Abstract][Full Text] [Related]  

  • 5. On-line monitoring of solutes in dialysate using wavelength-dependent absorption of ultraviolet radiation.
    Fridolin I; Lindberg LG
    Med Biol Eng Comput; 2003 May; 41(3):263-70. PubMed ID: 12803290
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Estimating total urea removal and protein catabolic rate by monitoring UV absorbance in spent dialysate.
    Uhlin F; Fridolin I; Lindberg LG; Magnusson M
    Nephrol Dial Transplant; 2005 Nov; 20(11):2458-64. PubMed ID: 16077147
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Do only small uremic toxins, chromophores, contribute to the online dialysis dose monitoring by UV absorbance?
    Arund J; Tanner R; Uhlin F; Fridolin I
    Toxins (Basel); 2012 Oct; 4(10):849-61. PubMed ID: 23162701
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Dialysis dose (Kt/V) and clearance variation sensitivity using measurement of ultraviolet-absorbance (on-line), blood urea, dialysate urea and ionic dialysance.
    Uhlin F; Fridolin I; Magnusson M; Lindberg LG
    Nephrol Dial Transplant; 2006 Aug; 21(8):2225-31. PubMed ID: 16611681
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Urea Rebound Assessment Based on UV Absorbance in Spent Dialysate.
    Tomson R; Uhlin F; Fridolin I
    ASAIO J; 2014; 60(4):459-65. PubMed ID: 24814831
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Automated monitoring of hemodialysis adequacy by dialysis machines: potential benefits to patients and cost savings.
    Daugirdas JT; Tattersall JE
    Kidney Int; 2010 Nov; 78(9):833-5. PubMed ID: 20948540
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Uric acid is the major determinant of absorbance in spent dialysate allowing spectrophotometric evaluation of dialysis dose.
    Donadio C; Calia D; Ghimenti S; Onor M; Colombini E; Fuoco R; Di Francesco F
    J Nephrol; 2014 Jun; 27(3):331-7. PubMed ID: 24535999
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Estimation of delivered dialysis dose by on-line monitoring of the ultraviolet absorbance in the spent dialysate.
    Uhlin F; Fridolin I; Lindberg LG; Magnusson M
    Am J Kidney Dis; 2003 May; 41(5):1026-36. PubMed ID: 12722037
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Optical Method and Biochemical Source for the Assessment of the Middle-Molecule Uremic Toxin β2-Microglobulin in Spent Dialysate.
    Paats J; Adoberg A; Arund J; Fridolin I; Lauri K; Leis L; Luman M; Tanner R
    Toxins (Basel); 2021 Mar; 13(4):. PubMed ID: 33807387
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Dialysis dose and nutrition assessment by optical on-line dialysis adequacy monitor.
    Luman M; Jerotskaja J; Lauri K; Fridolin I
    Clin Nephrol; 2009 Oct; 72(4):303-11. PubMed ID: 19825337
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Optical measurement of creatinine in spent dialysate.
    Tomson R; Fridolin I; Uhlin F; Holmar J; Lauri K; Luman M
    Clin Nephrol; 2013 Feb; 79(2):107-17. PubMed ID: 23110769
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Real-time Kt/V determination by ultraviolet absorbance in spent dialysate: technique validation.
    Castellarnau A; Werner M; Günthner R; Jakob M
    Kidney Int; 2010 Nov; 78(9):920-5. PubMed ID: 20631678
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effects of protein leakage on online monitoring of ultraviolet absorbance in spent dialysate.
    Yamamoto K; Hirakawa S; Murakami J; Akiba T; Mineshima M
    J Artif Organs; 2016 Sep; 19(3):278-82. PubMed ID: 27034069
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [On line monitoring using ultraviolet absorption for surveillance of clinical events during hemodialysis].
    Uhlin F; Fridolin I; Magnusson M; Lindberg LG
    J Ren Care; 2006; 32(3):141-6. PubMed ID: 17393808
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Estimation of removed uremic toxin indoxyl sulphate during hemodialysis by using optical data of the spent dialysate.
    Holmar J; Uhlin F; Ferenets R; Lauri K; Tanner R; Arund J; Luman M; Fridolin I
    Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():6707-10. PubMed ID: 24111282
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Removal of Urea, β2-Microglobulin, and Indoxyl Sulfate Assessed by Absorbance and Fluorescence in the Spent Dialysate During Hemodialysis.
    Lauri K; Arund J; Holmar J; Tanner R; Kalle S; Luman M; Fridolin I
    ASAIO J; 2020 Jun; 66(6):698-705. PubMed ID: 31425267
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]