These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

106 related articles for article (PubMed ID: 17945872)

  • 1. A new infusion pathway intactness monitoring system.
    Ogawa H; Yonezawa Y; Maki H; Ninomiya I; Sata K; Hamada S; Caldwell WM
    Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():4999-5000. PubMed ID: 17945872
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A new venous infusion pathway monitoring system.
    Maki H; Yonezawa Y; Ogawa H; Ninomiya I; Sata K; Hamada S; Caldwell WM
    Annu Int Conf IEEE Eng Med Biol Soc; 2007; 2007():2307-10. PubMed ID: 18002453
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A new venous infusion path monitoring system utilizing electrostatic induced potential.
    Ogawa H; Yonezawa Y; Maki H; Caldwell WM
    Annu Int Conf IEEE Eng Med Biol Soc; 2008; 2008():3301-3. PubMed ID: 19163413
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A new infusion pathway monitoring system utilizing electrostatic induced potential.
    Maki H; Yonezawa Y; Ogawa H; Ninomiya I; Sada K; Hamada S; Hahn AW; Caldwell WM
    Biomed Sci Instrum; 2006; 42():378-82. PubMed ID: 16817637
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A new bed-exiting alarm system for welfare facility residents.
    Ogawa H; Yonezawa Y; Maki H; Caldwell W
    Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():1734-7. PubMed ID: 19964261
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A new intelligent bed care system for hospital and home patients.
    Yonezawa Y; Miyamoto Y; Maki H; Ogawa H; Ninomiya I; Sada K; Hamada S; Caldwell WM
    Biomed Instrum Technol; 2005; 39(4):313-9. PubMed ID: 16111412
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A new drip infusion solution monitoring system with a free-flow detection function.
    Ogawa H; Maki H; Tsukamoto S; Yonezawa Y; Amano H; Caldwell W
    Annu Int Conf IEEE Eng Med Biol Soc; 2010; 2010():1214-7. PubMed ID: 21096118
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A remote monitoring system for patients with implantable ventricular assist devices with a personal handy phone system.
    Okamoto E; Shimanaka M; Suzuki S; Baba K; Mitamura Y
    ASAIO J; 1999; 45(3):194-8. PubMed ID: 10360722
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The Smart Patches and Wearable Band (W-Band) for comfortable sleep monitoring system.
    Lee S; Yan L; Roh T; Hong S; Yoo HJ
    Annu Int Conf IEEE Eng Med Biol Soc; 2011; 2011():6915-8. PubMed ID: 22255928
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Sensium: an ultra-low-power wireless body sensor network platform: design & application challenges.
    Wong AW; McDonagh D; Omeni O; Nunn C; Hernandez-Silveira M; Burdett AJ
    Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():6576-9. PubMed ID: 19964698
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Miniaturized module for the wireless transmission of measurements with Bluetooth.
    Roth H; Schwaibold M; Moor C; Schöchlin J; Bolz A
    Biomed Tech (Berl); 2002; 47 Suppl 1 Pt 2():854-6. PubMed ID: 12465323
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A new microcomputer-based safety and life support system for solitary-living elderly people.
    Miyauchi K; Yonezawa Y; Maki H; Ogawa H; Hahn AW; Caldwell WM
    Biomed Sci Instrum; 2003; 39():179-82. PubMed ID: 12724890
    [TBL] [Abstract][Full Text] [Related]  

  • 13. 24 hour ambulatory research system supporting multiple physiologic sensors.
    Ellingson RM; Oken BS; Zajdel DP; Flegal KE; Kishiyama S; Thong T
    Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():5928-31. PubMed ID: 17945921
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Monitoring instrumentation. Isolated inputs, electrosurgery filtering, burns protection: what does it mean?
    Uyttendaele K; Grobstein S; Svetz P
    Acta Anaesthesiol Belg; 1978; 29(3):317-30. PubMed ID: 751436
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The development of a microprocessor system for simultaneously monitoring heart rate from multiple subjects.
    Peterson JT; Pohorecky LA
    Comput Methods Programs Biomed; 1987 Jun; 24(3):169-77. PubMed ID: 3608442
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Safety factors in the remote control of infusion devices.
    Cantraine FR; Coussaert EJ
    Int J Clin Monit Comput; 1996 Feb; 13(1):45-55. PubMed ID: 8738599
    [TBL] [Abstract][Full Text] [Related]  

  • 17. MINA: monitoring of intravenous anaesthesia. A system to monitor the infusion of 4 intravenous drugs under the control of a personal computer.
    Cantraine F; Coussaert E; d'Hollander A; Barvais L
    Int J Clin Monit Comput; 1989 Apr; 6(2):109-17. PubMed ID: 2794738
    [No Abstract]   [Full Text] [Related]  

  • 18. Physiologic monitoring systems.
    Health Devices; 1999; 28(1-2):6-77. PubMed ID: 10091048
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A mobile phone-based ECG monitoring system.
    Iwamoto J; Yonezawa Y; Maki H; Ogawa H; Ninomiya I; Sada K; Hamada S; Hahn AW; Caldwell WM
    Biomed Sci Instrum; 2006; 42():217-22. PubMed ID: 16817611
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Micropower circuits for bidirectional wireless telemetry in neural recording applications.
    Neihart NM; Harrison RR
    IEEE Trans Biomed Eng; 2005 Nov; 52(11):1950-9. PubMed ID: 16285399
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.