These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

196 related articles for article (PubMed ID: 17945876)

  • 1. Current source for multifrequency broadband electrical bioimpedance spectroscopy systems. A novel approach.
    Seoane F; Bragós R; Lindecrantz K
    Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():5121-5. PubMed ID: 17945876
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The differential Howland current source with high signal to noise ratio for bioimpedance measurement system.
    Liu J; Qiao X; Wang M; Zhang W; Li G; Lin L
    Rev Sci Instrum; 2014 May; 85(5):055111. PubMed ID: 24880419
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Bioimpedance at the bedside: current applications, limitations, and opportunities.
    Mulasi U; Kuchnia AJ; Cole AJ; Earthman CP
    Nutr Clin Pract; 2015 Apr; 30(2):180-93. PubMed ID: 25613832
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Wideband impedance spectrum analyzer for process automation applications.
    Doerner S; Schneider T; Hauptmann PR
    Rev Sci Instrum; 2007 Oct; 78(10):105101. PubMed ID: 17979452
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Impedance spectroscopy using maximum length sequences: application to single cell analysis.
    Gawad S; Sun T; Green NG; Morgan H
    Rev Sci Instrum; 2007 May; 78(5):054301. PubMed ID: 17552843
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The simulation of current generator design for multi-frequency electrical impedance tomograph.
    Chen CY; Lu YY; Huang WL; Cheng KS
    Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():6072-5. PubMed ID: 17945933
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Investigation of voltage source design's for Electrical Impedance Mammography (EIM) Systems.
    Qureshi TR; Chatwin CR; Zhou Z; Li N; Wang W
    Annu Int Conf IEEE Eng Med Biol Soc; 2012; 2012():1582-5. PubMed ID: 23366207
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of a new integrated current source with the modified Howland circuit for EIT applications.
    Hong H; Rahal M; Demosthenous A; Bayford RH
    Physiol Meas; 2009 Oct; 30(10):999-1007. PubMed ID: 19706961
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Electrical impedance tomography system: an open access circuit design.
    Soleimani M
    Biomed Eng Online; 2006 May; 5():28. PubMed ID: 16672061
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Bioimpedance tomography (electrical impedance tomography).
    Bayford RH
    Annu Rev Biomed Eng; 2006; 8():63-91. PubMed ID: 16834552
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A high-precision voltage source for EIT.
    Saulnier GJ; Ross AS; Liu N
    Physiol Meas; 2006 May; 27(5):S221-36. PubMed ID: 16636413
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Electrical impedance tomography spectroscopy (EITS) for human head imaging.
    Yerworth RJ; Bayford RH; Brown B; Milnes P; Conway M; Holder DS
    Physiol Meas; 2003 May; 24(2):477-89. PubMed ID: 12812431
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Bioimpedance analysis: a guide to simple design and implementation.
    Aroom KR; Harting MT; Cox CS; Radharkrishnan RS; Smith C; Gill BS
    J Surg Res; 2009 May; 153(1):23-30. PubMed ID: 18805550
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Technical note. A design study of a bioelectric amplifier and improvement of its parameters.
    Amer MB
    J Med Eng Technol; 1999; 23(1):15-9. PubMed ID: 10202698
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A study of composite electrode-tissue impedance.
    Robinson RL; Davidson JL; Wright P; Pomfrett CJ; McCann H
    Annu Int Conf IEEE Eng Med Biol Soc; 2008; 2008():1171-4. PubMed ID: 19162873
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A parallel broadband real-time system for electrical impedance tomography.
    Casas O; Rosell J; Bragós R; Lozano A; Riu PJ
    Physiol Meas; 1996 Nov; 17 Suppl 4A():A1-6. PubMed ID: 9001596
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Parasitic Effects on Electrical Bioimpedance Systems: Critical Review.
    Marcôndes DWC; Paterno AS; Bertemes-Filho P
    Sensors (Basel); 2022 Nov; 22(22):. PubMed ID: 36433301
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Body composition modeling in the calf using an equivalent circuit model of multi-frequency bioimpedance analysis.
    Zhu F; Leonard EF; Levin NW
    Physiol Meas; 2005 Apr; 26(2):S133-43. PubMed ID: 15798226
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Current source design for electrical impedance tomography.
    Ross AS; Saulnier GJ; Newell JC; Isaacson D
    Physiol Meas; 2003 May; 24(2):509-16. PubMed ID: 12812434
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A method for modelling and optimizing an electrical impedance tomography system.
    Hartinger AE; Gagnon H; Guardo R
    Physiol Meas; 2006 May; 27(5):S51-64. PubMed ID: 16636420
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.