These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

172 related articles for article (PubMed ID: 17947096)

  • 1. A high-resolution anisotropic finite-volume head model for EEG source analysis.
    Cook MJ; Koles ZJ
    Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():4536-9. PubMed ID: 17947096
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Dipole estimation errors due to differences in modeling anisotropic conductivities in realistic head models for EEG source analysis.
    Hallez H; Vanrumste B; Van Hese P; Delputte S; Lemahieu I
    Phys Med Biol; 2008 Apr; 53(7):1877-94. PubMed ID: 18364544
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The effect of tissue anisotropy on the EEG inverse problem.
    Cook MJ; Koles ZJ
    Annu Int Conf IEEE Eng Med Biol Soc; 2008; 2008():4563-6. PubMed ID: 19163731
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Influence of anisotropic electrical conductivity in white matter tissue on the EEG/MEG forward and inverse solution. A high-resolution whole head simulation study.
    Güllmar D; Haueisen J; Reichenbach JR
    Neuroimage; 2010 May; 51(1):145-63. PubMed ID: 20156576
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A second-order finite element algorithm for solving the three-dimensional EEG forward problem.
    Zhang YC; Zhu SA; He B
    Phys Med Biol; 2004 Jul; 49(13):2975-87. PubMed ID: 15285259
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Influence of white matter anisotropy on EEG source localization: an experimental study.
    Lee WH; Liu Z; Mueller BA; Lim K; He B
    Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():2923-5. PubMed ID: 19964792
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A finite-element reciprocity solution for EEG forward modeling with realistic individual head models.
    Ziegler E; Chellappa SL; Gaggioni G; Ly JQM; Vandewalle G; André E; Geuzaine C; Phillips C
    Neuroimage; 2014 Dec; 103():542-551. PubMed ID: 25204867
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A finite difference method with reciprocity used to incorporate anisotropy in electroencephalogram dipole source localization.
    Hallez H; Vanrumste B; Van Hese P; D'Asseler Y; Lemahieu I; Van de Walle R
    Phys Med Biol; 2005 Aug; 50(16):3787-806. PubMed ID: 16077227
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A realistic, accurate and fast source modeling approach for the EEG forward problem.
    Miinalainen T; Rezaei A; Us D; Nüßing A; Engwer C; Wolters CH; Pursiainen S
    Neuroimage; 2019 Jan; 184():56-67. PubMed ID: 30165251
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Influence of skull anisotropy for the forward and inverse problem in EEG: simulation studies using FEM on realistic head models.
    Marin G; Guerin C; Baillet S; Garnero L; Meunier G
    Hum Brain Mapp; 1998; 6(4):250-69. PubMed ID: 9704264
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Methods for high-resolution anisotropic finite element modeling of the human head: automatic MR white matter anisotropy-adaptive mesh generation.
    Lee WH; Kim TS
    Med Eng Phys; 2012 Jan; 34(1):85-98. PubMed ID: 21820347
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A Mixed Finite Element Method to Solve the EEG Forward Problem.
    Vorwerk J; Engwer C; Pursiainen S; Wolters CH
    IEEE Trans Med Imaging; 2017 Apr; 36(4):930-941. PubMed ID: 27831869
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A computationally efficient method for accurately solving the EEG forward problem in a finely discretized head model.
    Neilson LA; Kovalyov M; Koles ZJ
    Clin Neurophysiol; 2005 Oct; 116(10):2302-14. PubMed ID: 16125461
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A FDM anisotropic formulation for EEG simulation.
    Bruno P; Hyttinen J; Inchingolo P; Magrofuoco A; Mininel S; Vatta F
    Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():1121-5. PubMed ID: 17946024
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Influence of tissue conductivity anisotropy on EEG/MEG field and return current computation in a realistic head model: a simulation and visualization study using high-resolution finite element modeling.
    Wolters CH; Anwander A; Tricoche X; Weinstein D; Koch MA; MacLeod RS
    Neuroimage; 2006 Apr; 30(3):813-26. PubMed ID: 16364662
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A Finite Element Solution of the Forward Problem in EEG for Multipolar Sources.
    Beltrachini L
    IEEE Trans Neural Syst Rehabil Eng; 2019 Mar; 27(3):368-377. PubMed ID: 30561347
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Experimental validation of the influence of white matter anisotropy on the intracranial EEG forward solution.
    Bangera NB; Schomer DL; Dehghani N; Ulbert I; Cash S; Papavasiliou S; Eisenberg SR; Dale AM; Halgren E
    J Comput Neurosci; 2010 Dec; 29(3):371-87. PubMed ID: 20063051
    [TBL] [Abstract][Full Text] [Related]  

  • 18. An advanced boundary element method (BEM) implementation for the forward problem of electromagnetic source imaging.
    Akalin-Acar Z; Gençer NG
    Phys Med Biol; 2004 Nov; 49(21):5011-28. PubMed ID: 15584534
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Using reciprocity for relating the simulation of transcranial current stimulation to the EEG forward problem.
    Wagner S; Lucka F; Vorwerk J; Herrmann CS; Nolte G; Burger M; Wolters CH
    Neuroimage; 2016 Oct; 140():163-73. PubMed ID: 27125841
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The role of blood vessels in high-resolution volume conductor head modeling of EEG.
    Fiederer LDJ; Vorwerk J; Lucka F; Dannhauer M; Yang S; Dümpelmann M; Schulze-Bonhage A; Aertsen A; Speck O; Wolters CH; Ball T
    Neuroimage; 2016 Mar; 128():193-208. PubMed ID: 26747748
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.