190 related articles for article (PubMed ID: 17950627)
1. Physiological noise modelling for spinal functional magnetic resonance imaging studies.
Brooks JC; Beckmann CF; Miller KL; Wise RG; Porro CA; Tracey I; Jenkinson M
Neuroimage; 2008 Jan; 39(2):680-92. PubMed ID: 17950627
[TBL] [Abstract][Full Text] [Related]
2. Assessment of physiological noise modelling methods for functional imaging of the spinal cord.
Kong Y; Jenkinson M; Andersson J; Tracey I; Brooks JC
Neuroimage; 2012 Apr; 60(2):1538-49. PubMed ID: 22178812
[TBL] [Abstract][Full Text] [Related]
3. Robust spinal cord resting-state fMRI using independent component analysis-based nuisance regression noise reduction.
Hu Y; Jin R; Li G; Luk KD; Wu EX
J Magn Reson Imaging; 2018 Nov; 48(5):1421-1431. PubMed ID: 29659087
[TBL] [Abstract][Full Text] [Related]
4. Reduction of physiological noise with independent component analysis improves the detection of nociceptive responses with fMRI of the human spinal cord.
Xie G; Piché M; Khoshnejad M; Perlbarg V; Chen JI; Hoge RD; Benali H; Rossignol S; Rainville P; Cohen-Adad J
Neuroimage; 2012 Oct; 63(1):245-52. PubMed ID: 22776463
[TBL] [Abstract][Full Text] [Related]
5. Development and validation of retrospective spinal cord motion time-course estimates (RESPITE) for spin-echo spinal fMRI: Improved sensitivity and specificity by means of a motion-compensating general linear model analysis.
Figley CR; Stroman PW
Neuroimage; 2009 Jan; 44(2):421-7. PubMed ID: 18835581
[TBL] [Abstract][Full Text] [Related]
6. Characterization of cardiac-related noise in fMRI of the cervical spinal cord.
Piché M; Cohen-Adad J; Nejad MK; Perlbarg V; Xie G; Beaudoin G; Benali H; Rainville P
Magn Reson Imaging; 2009 Apr; 27(3):300-10. PubMed ID: 18801632
[TBL] [Abstract][Full Text] [Related]
7. Spinal cord functional MRI at 3 T: gradient echo echo-planar imaging versus turbo spin echo.
Bouwman CJ; Wilmink JT; Mess WH; Backes WH
Neuroimage; 2008 Nov; 43(2):288-96. PubMed ID: 18706507
[TBL] [Abstract][Full Text] [Related]
8. Brainstem functional magnetic resonance imaging: disentangling signal from physiological noise.
Harvey AK; Pattinson KT; Brooks JC; Mayhew SD; Jenkinson M; Wise RG
J Magn Reson Imaging; 2008 Dec; 28(6):1337-44. PubMed ID: 19025940
[TBL] [Abstract][Full Text] [Related]
9. Physiological noise correction using ECG-derived respiratory signals for enhanced mapping of spontaneous neuronal activity with simultaneous EEG-fMRI.
Abreu R; Nunes S; Leal A; Figueiredo P
Neuroimage; 2017 Jul; 154():115-127. PubMed ID: 27530551
[TBL] [Abstract][Full Text] [Related]
10. Single, slice-specific z-shim gradient pulses improve T2*-weighted imaging of the spinal cord.
Finsterbusch J; Eippert F; Büchel C
Neuroimage; 2012 Feb; 59(3):2307-15. PubMed ID: 21979381
[TBL] [Abstract][Full Text] [Related]
11. Assessment of data acquisition parameters, and analysis techniques for noise reduction in spinal cord fMRI data.
Bosma RL; Stroman PW
Magn Reson Imaging; 2014 Jun; 32(5):473-81. PubMed ID: 24602827
[TBL] [Abstract][Full Text] [Related]
12. Brain and cord myelin water imaging: a progressive multiple sclerosis biomarker.
Kolind S; Seddigh A; Combes A; Russell-Schulz B; Tam R; Yogendrakumar V; Deoni S; Sibtain NA; Traboulsee A; Williams SC; Barker GJ; Brex PA
Neuroimage Clin; 2015; 9():574-80. PubMed ID: 26594633
[TBL] [Abstract][Full Text] [Related]
13. Effect of Physiological Noise on Thoracolumbar Spinal Cord Functional Magnetic Resonance Imaging in 3T Magnetic Field.
Dehghani H; Oghabian MA; Batouli SAH; Arab Kheradmand J; Khatibi A
Basic Clin Neurosci; 2020; 11(6):737-751. PubMed ID: 33850611
[TBL] [Abstract][Full Text] [Related]
14. Functional magnetic resonance imaging of the cervical spinal cord during thermal stimulation across consecutive runs.
Weber KA; Chen Y; Wang X; Kahnt T; Parrish TB
Neuroimage; 2016 Dec; 143():267-279. PubMed ID: 27616641
[TBL] [Abstract][Full Text] [Related]
15. Pain fMRI in rat cervical spinal cord: an echo planar imaging evaluation of sensitivity of BOLD and blood volume-weighted fMRI.
Zhao F; Williams M; Meng X; Welsh DC; Grachev ID; Hargreaves R; Williams DS
Neuroimage; 2009 Jan; 44(2):349-62. PubMed ID: 18835453
[TBL] [Abstract][Full Text] [Related]
16. Signal fluctuations in fMRI data acquired with 2D-EPI and 3D-EPI at 7 Tesla.
Jorge J; Figueiredo P; van der Zwaag W; Marques JP
Magn Reson Imaging; 2013 Feb; 31(2):212-20. PubMed ID: 22921734
[TBL] [Abstract][Full Text] [Related]
17. A quantitative comparison of BOLD fMRI responses to noxious and innocuous stimuli in the human spinal cord.
Summers PE; Ferraro D; Duzzi D; Lui F; Iannetti GD; Porro CA
Neuroimage; 2010 May; 50(4):1408-15. PubMed ID: 20096788
[TBL] [Abstract][Full Text] [Related]
18. Integration of motion correction and physiological noise regression in fMRI.
Jones TB; Bandettini PA; Birn RM
Neuroimage; 2008 Aug; 42(2):582-90. PubMed ID: 18583155
[TBL] [Abstract][Full Text] [Related]
19. MRI of the abnormal cervical spinal cord using 2D spoiled gradient echo multiecho sequence (MEDIC) with magnetization transfer saturation pulse. A T2* weighted feasibility study.
Held P; Dorenbeck U; Seitz J; Fründ R; Albrich H
J Neuroradiol; 2003 Mar; 30(2):83-90. PubMed ID: 12717293
[TBL] [Abstract][Full Text] [Related]
20. Entropy-based analysis for diffusion anisotropy mapping of healthy and myelopathic spinal cord.
Cui JL; Wen CY; Hu Y; Li TH; Luk KD
Neuroimage; 2011 Feb; 54(3):2125-31. PubMed ID: 20951216
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]