  • 21. Development and application of a validated HPLC method for the analysis of dissolution samples of gabapentin drug products.
    Gupta A; Ciavarella AB; Sayeed VA; Khan MA; Faustino PJ
    J Pharm Biomed Anal; 2008 Jan; 46(1):181-6. PubMed ID: 17935923
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Rapid determination of thiamine, riboflavin, niacinamide, pantothenic acid, pyridoxine, folic acid and ascorbic acid in Vitamins with Minerals Tablets by high-performance liquid chromatography with diode array detector.
    Jin P; Xia L; Li Z; Che N; Zou D; Hu X
    J Pharm Biomed Anal; 2012 Nov; 70():151-7. PubMed ID: 22785377
    [TBL] [Abstract][Full Text] [Related]  

  • 23. High performance liquid chromatography assay method for simultaneous quantitation of formoterol and budesonide in Symbicort Turbuhaler.
    Assi KH; Tarsin W; Chrystyn H
    J Pharm Biomed Anal; 2006 Apr; 41(1):325-8. PubMed ID: 16378706
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Assay of artemether, methylparaben and propylparaben in a formulated paediatric antimalarial dry suspension.
    Atemnkeng MA; Marchand E; Plaizier-Vercammen J
    J Pharm Biomed Anal; 2007 Jan; 43(2):727-32. PubMed ID: 17074460
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Stability study of simvastatin under hydrolytic conditions assessed by liquid chromatography.
    Alvarez-Lueje A; Valenzuela C; Squella JA; Núñez-Vergara LJ
    J AOAC Int; 2005; 88(6):1631-6. PubMed ID: 16526443
    [TBL] [Abstract][Full Text] [Related]  

  • 26. HPLC analysis, isolation and identification of a new degradation product in carvedilol tablets.
    Galanopoulou O; Rozou S; Antoniadou-Vyza E
    J Pharm Biomed Anal; 2008 Sep; 48(1):70-7. PubMed ID: 18584991
    [TBL] [Abstract][Full Text] [Related]  

  • 27. A stability-indicating high-performance liquid chromatographic method for the determination of methocarbamol in veterinary preparations.
    Rosasco MA; Ceresole R; Forastieri CC; Segall AI
    J AOAC Int; 2009; 92(5):1602-5. PubMed ID: 19916399
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Kinetics investigation and determination of pipoxolan hydrochloride and its degradant using liquid chromatography.
    Hadad GM; Salam RA; Hamfeed EA
    J AOAC Int; 2013; 96(4):758-64. PubMed ID: 24000748
    [TBL] [Abstract][Full Text] [Related]  

  • 29. RP-HPLC method for simultaneous estimation of bisoprolol fumarate and hydrochlorothiazide in tablet formulation.
    Joshi SJ; Karbhari PA; Bhoir SI; Bindu KS; Das C
    J Pharm Biomed Anal; 2010 Jul; 52(3):362-71. PubMed ID: 19926421
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Spectrophotometric and chromatographic determination of rabeprazole in presence of its degradation products.
    El-Gindy A; El-Yazby F; Maher MM
    J Pharm Biomed Anal; 2003 Feb; 31(2):229-42. PubMed ID: 12609662
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Quantitative determination of insulin entrapment efficiency in triblock copolymeric nanoparticles by high-performance liquid chromatography.
    Xu X; Fu Y; Hu H; Duan Y; Zhang Z
    J Pharm Biomed Anal; 2006 Apr; 41(1):266-73. PubMed ID: 16303273
    [TBL] [Abstract][Full Text] [Related]  

  • 32. High-performance liquid chromatographic determination of Ethamsylate in urine and tablets.
    El-Gindy A; Nassar MW; Attia KA; Abu-Seada HH; El-Ghandour M
    J AOAC Int; 2013; 96(4):730-6. PubMed ID: 24000744
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Development and validation of a reversed-phase HPLC method for the determination of ezetimibe in pharmaceutical dosage forms.
    Sistla R; Tata VS; Kashyap YV; Chandrasekar D; Diwan PV
    J Pharm Biomed Anal; 2005 Sep; 39(3-4):517-22. PubMed ID: 15936912
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Simultaneous and rapid quantitation of benazepril and benazeprilat in human plasma by high performance liquid chromatography with ultraviolet detection.
    Wang XD; Chan E; Chen X; Liao XX; Tang C; Zhou ZW; Huang M; Zhou SF
    J Pharm Biomed Anal; 2007 May; 44(1):224-30. PubMed ID: 17289327
    [TBL] [Abstract][Full Text] [Related]  

  • 35. First derivative spectrophotometric and LC determination of benoxinate hydrochloride and its degradation products.
    El-Gindy A
    J Pharm Biomed Anal; 2000 Mar; 22(2):215-34. PubMed ID: 10719904
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Determination of tianeptine in tablets by high-performance liquid chromatography with fluorescence detection.
    Ulu ST
    J AOAC Int; 2007; 90(3):720-4. PubMed ID: 17580625
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Optimization and validation of an RP-HPLC method for direct determination of metformin hydrochloride in human urine and in a dosage form.
    El-Gindy A; Nassar MW; El-Abasawy NM; Attia KA; Al-Shabrawi M
    J AOAC Int; 2010; 93(6):1821-8. PubMed ID: 21313808
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Derivative spectrophotometric, thin layer chromatographic-densitometric and high performance liquid chromatographic determination of trifluoperazine hydrochloride in presence of its hydrogen peroxide induced-degradation product.
    El-Gindy A; El-Zeany B; Awad T; Shabana MM
    J Pharm Biomed Anal; 2002 Jan; 27(1-2):9-18. PubMed ID: 11682205
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Development and validation of a gradient HPLC method for the determination of clindamycin and related compounds in a novel tablet formulation.
    Platzer DJ; White BA
    J Pharm Biomed Anal; 2006 Apr; 41(1):84-8. PubMed ID: 16298506
    [TBL] [Abstract][Full Text] [Related]  

  • 40. UV partial least-squares calibration and liquid chromatographic methods for direct quantitation of levofloxacin in urine.
    El-Gindy A; Emara S; Mostafa A
    J AOAC Int; 2007; 90(5):1258-65. PubMed ID: 17955970
    [TBL] [Abstract][Full Text] [Related]  