127 related articles for article (PubMed ID: 17969110)
1. Ultrashort echo time spectroscopic imaging (UTESI) of cortical bone.
Du J; Hamilton G; Takahashi A; Bydder M; Chung CB
Magn Reson Med; 2007 Nov; 58(5):1001-9. PubMed ID: 17969110
[TBL] [Abstract][Full Text] [Related]
2. Ultrashort TE spectroscopic imaging (UTESI): application to the imaging of short T2 relaxation tissues in the musculoskeletal system.
Du J; Takahashi AM; Chung CB
J Magn Reson Imaging; 2009 Feb; 29(2):412-21. PubMed ID: 19161197
[TBL] [Abstract][Full Text] [Related]
3. Orientational analysis of the Achilles tendon and enthesis using an ultrashort echo time spectroscopic imaging sequence.
Du J; Chiang AJ; Chung CB; Statum S; Znamirowski R; Takahashi A; Bydder GM
Magn Reson Imaging; 2010 Feb; 28(2):178-84. PubMed ID: 19695811
[TBL] [Abstract][Full Text] [Related]
4. Magnetic resonance imaging of cortical bone with ultrashort TE pulse sequences.
Reichert IL; Robson MD; Gatehouse PD; He T; Chappell KE; Holmes J; Girgis S; Bydder GM
Magn Reson Imaging; 2005 Jun; 23(5):611-8. PubMed ID: 16051035
[TBL] [Abstract][Full Text] [Related]
5. Assessment of cortical bone with clinical and ultrashort echo time sequences.
Du J; Hermida JC; Diaz E; Corbeil J; Znamirowski R; D'Lima DD; Bydder GM
Magn Reson Med; 2013 Sep; 70(3):697-704. PubMed ID: 23001864
[TBL] [Abstract][Full Text] [Related]
6. Qualitative and quantitative ultrashort echo time (UTE) imaging of cortical bone.
Du J; Carl M; Bydder M; Takahashi A; Chung CB; Bydder GM
J Magn Reson; 2010 Dec; 207(2):304-11. PubMed ID: 20980179
[TBL] [Abstract][Full Text] [Related]
7. Three-dimensional adiabatic inversion recovery prepared ultrashort echo time cones (3D IR-UTE-Cones) imaging of cortical bone in the hip.
Nazaran A; Carl M; Ma Y; Jerban S; Zhu Y; Lu X; Du J; Chang EY
Magn Reson Imaging; 2017 Dec; 44():60-64. PubMed ID: 28716680
[TBL] [Abstract][Full Text] [Related]
8. Ultrashort echo time imaging using pointwise encoding time reduction with radial acquisition (PETRA).
Grodzki DM; Jakob PM; Heismann B
Magn Reson Med; 2012 Feb; 67(2):510-8. PubMed ID: 21721039
[TBL] [Abstract][Full Text] [Related]
9. Weighted subtraction in 3D ultrashort echo time (UTE) imaging for visualization of short T2 tissues of the knee.
Lee YH; Kim S; Song HT; Kim I; Suh JS
Acta Radiol; 2014 May; 55(4):454-61. PubMed ID: 23934936
[TBL] [Abstract][Full Text] [Related]
10. Two-dimensional ultrashort echo time imaging using a spiral trajectory.
Du J; Bydder M; Takahashi AM; Chung CB
Magn Reson Imaging; 2008 Apr; 26(3):304-12. PubMed ID: 18096346
[TBL] [Abstract][Full Text] [Related]
11. T
Guo T; Ma Y; Jerban S; Jang H; Zhao W; Chang EY; Chen M; Bydder GM; Du J
Magn Reson Med; 2020 Aug; 84(2):634-645. PubMed ID: 31863519
[TBL] [Abstract][Full Text] [Related]
12. Human imaging of phosphorus in cortical and trabecular bone in vivo.
Robson MD; Gatehouse PD; Bydder GM; Neubauer S
Magn Reson Med; 2004 May; 51(5):888-92. PubMed ID: 15122669
[TBL] [Abstract][Full Text] [Related]
13. Clinical ultrashort echo time imaging of bone and other connective tissues.
Robson MD; Bydder GM
NMR Biomed; 2006 Nov; 19(7):765-80. PubMed ID: 17075960
[TBL] [Abstract][Full Text] [Related]
14. Effects of inversion time on inversion recovery prepared ultrashort echo time (IR-UTE) imaging of bound and pore water in cortical bone.
Li S; Ma L; Chang EY; Shao H; Chen J; Chung CB; Bydder GM; Du J
NMR Biomed; 2015 Jan; 28(1):70-8. PubMed ID: 25348196
[TBL] [Abstract][Full Text] [Related]
15. Three-dimensional ultrashort echo time imaging of solid polymers on a 3-Tesla whole-body MRI scanner.
Springer F; Martirosian P; Schwenzer NF; Szimtenings M; Kreisler P; Claussen CD; Schick F
Invest Radiol; 2008 Nov; 43(11):802-8. PubMed ID: 18923260
[TBL] [Abstract][Full Text] [Related]
16. Ultrashort TE spectroscopic imaging (UTESI) using complex highly-constrained backprojection with local reconstruction (HYPR LR).
Wang K; Du J; O'Halloran R; Fain S; Kecskemeti S; Wieben O; Johnson KM; Mistretta C
Magn Reson Med; 2009 Jul; 62(1):127-34. PubMed ID: 19353656
[TBL] [Abstract][Full Text] [Related]
17. MR imaging near metal with undersampled 3D radial UTE-MAVRIC sequences.
Carl M; Koch K; Du J
Magn Reson Med; 2013 Jan; 69(1):27-36. PubMed ID: 22374824
[TBL] [Abstract][Full Text] [Related]
18. Ultrashort TE imaging with off-resonance saturation contrast (UTE-OSC).
Du J; Takahashi AM; Bydder M; Chung CB; Bydder GM
Magn Reson Med; 2009 Aug; 62(2):527-31. PubMed ID: 19449436
[TBL] [Abstract][Full Text] [Related]
19. Selective maximization of (31)P MR spectroscopic signals of in vivo human brain metabolites at 3T.
Blenman RA; Port JD; Felmlee JP
J Magn Reson Imaging; 2007 Mar; 25(3):628-34. PubMed ID: 17279535
[TBL] [Abstract][Full Text] [Related]
20. Ultrashort TE chemical shift imaging (UTE-CSI).
Robson MD; Tyler DJ; Neubauer S
Magn Reson Med; 2005 Feb; 53(2):267-74. PubMed ID: 15678544
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]