BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

131 related articles for article (PubMed ID: 17971656)

  • 1. Head-to-head comparison of dobutamine stress echocardiography and cardiac computed tomography for the detection of significant coronary artery disease.
    Nixdorff U; Küfner C; Achenbach S; Stilianakis N; Voigt JU; Flachskampf FA; Daniel WG; Ropers D
    Cardiology; 2008; 110(2):81-6. PubMed ID: 17971656
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Dobutamine stress echocardiography and cardiac troponin T for the detection of significant coronary artery disease and predicting outcome in renal transplant candidates.
    Sharma R; Pellerin D; Gaze DC; Shah JS; Streather CP; Collinson PO; Brecker SJ
    Eur J Echocardiogr; 2005 Oct; 6(5):327-35. PubMed ID: 15985387
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Head to head comparison of transesophageal and transthoracic contrast-enhanced echocardiography during dobutamine administration for the detection of coronary artery disease.
    Cosyns B; Lancellotti P; Van Camp G; Droogmans S; Schoors D
    Int J Cardiol; 2008 Sep; 129(1):105-10. PubMed ID: 17719663
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Lower limb pneumatic compression during dobutamine stress echocardiography in patients with normal resting wall motion: will it increase diagnostic accuracy?
    Abdel-Salam Z; Allam L; Wadie B; Enany B; Nammas W
    Kardiol Pol; 2015; 73(8):620-6. PubMed ID: 25733177
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of (99)mTc-methoxyisobutylisonitrile myocardial single-photon emission computed tomography and electron beam computed tomography for detecting coronary artery disease in patients with no myocardial infarction.
    Yao ZM; Li W; Qu WY; Zhou C; He Q; Ji FS
    Chin Med J (Engl); 2004 May; 117(5):700-5. PubMed ID: 15161537
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Value of dobutamine stress echocardiography for the diagnosis of coronary artery disease in women with aortic valve stenosis].
    Płońska E; Szyszka A; Olszewski R; Gasior Z; Gackowski A; Maciejewski M; Kamiński L; Kossuth I; Gościniak P; Kasprzak J
    Pol Merkur Lekarski; 2004 May; 16(95):456-60. PubMed ID: 15518426
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Cardiac testing for coronary artery disease in potential kidney transplant recipients.
    Wang LW; Fahim MA; Hayen A; Mitchell RL; Baines L; Lord S; Craig JC; Webster AC
    Cochrane Database Syst Rev; 2011 Dec; 2011(12):CD008691. PubMed ID: 22161434
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of safety and efficacy of the early injection of atropine during dobutamine stress echocardiography with the conventional protocol.
    Tsutsui JM; Osório AF; Lario FA; Fernandes DR; Sodre G; Andrade JL; Ramires JA; Mathias W
    Am J Cardiol; 2004 Dec; 94(11):1367-72. PubMed ID: 15566905
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Uselessness of high-sensitivity cardiac troponins to improve diagnostic accuracy of dobutamine stress echocardiography in high-risk diabetic patients].
    Aboukhoudir F; Rekik S; Latil Plat F; Aboukhoudir I; Kadem M; Benamo E; Pansieri M
    Ann Cardiol Angeiol (Paris); 2014 Nov; 63(5):307-11. PubMed ID: 24972986
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Mechanisms of regional wall motion abnormalities in contrast-enhanced dobutamine stress echocardiography.
    Heinicke N; Benesch B; Kaiser T; Debl K; Segmüller M; Schönberger J; Marienhagen J; Eilles C; Riegger GA; Holmer S; Luchner A
    Clin Res Cardiol; 2006 Dec; 95(12):650-6. PubMed ID: 16998740
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Left Atrial Volume Index at Peak Dobutamine Stress Echocardiography Predicts the Extent of Coronary Artery Disease in Patients with Normal Resting Wall Motion.
    Abdel-Salam Z; El-Hammady W; Abdel-Sattar A; Nammas W
    Echocardiography; 2015 Nov; 32(11):1662-9. PubMed ID: 25892307
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of contrast-enhanced real-time live 3-dimensional dobutamine stress echocardiography with contrast 2-dimensional echocardiography for detecting stress-induced wall-motion abnormalities.
    Takeuchi M; Otani S; Weinert L; Spencer KT; Lang RM
    J Am Soc Echocardiogr; 2006 Mar; 19(3):294-9. PubMed ID: 16500492
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of squatting stress echocardiography and dobutamine stress echocardiography for the diagnosis of coronary artery disease.
    Chandraratna PA; Kuznetsov VA; Mohar DS; Sidarous PF; Scheutz J; Krinochkin DV; Pak YA; Mohar P; Arawgoda U
    Echocardiography; 2012 Jul; 29(6):695-9. PubMed ID: 22486460
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Early atropine-dobutamine echocardiography in diabetic patients.
    Eweda I; Abdel-Salam A; Nammas W
    Acta Cardiol; 2011 Oct; 66(5):595-601. PubMed ID: 22032053
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Stress echocardiography: abnormal response of tissue Doppler-derived indices to dobutamine in the absence of obstructive coronary artery disease in patients with chronic renal failure.
    Jassal DS; Neilan TG; Picard MH; Wood MJ
    Echocardiography; 2007 Jul; 24(6):580-6. PubMed ID: 17584197
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The additional utility of two-dimensional strain in detection of coronary artery disease presence and localization in patients undergoing dobutamine stress echocardiogram.
    Roushdy A; Abou El Seoud Y; Abd Elrahman M; Wadeaa B; Eletriby A; Abd El Salam Z
    Echocardiography; 2017 Jul; 34(7):1010-1019. PubMed ID: 28548371
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Dobutamine stress cardiac magnetic resonance versus echocardiography for the assessment of outcome in patients with suspected or known coronary artery disease. Are the two imaging modalities comparable?
    Bikiri E; Mereles D; Voss A; Greiner S; Hess A; Buss SJ; Hofmann NP; Giannitsis E; Katus HA; Korosoglou G
    Int J Cardiol; 2014 Feb; 171(2):153-60. PubMed ID: 24342416
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Dobutamine stress echocardiography for the detection of coronary artery disease in women.
    Geleijnse ML; Krenning BJ; Soliman OI; Nemes A; Galema TW; ten Cate FJ
    Am J Cardiol; 2007 Mar; 99(5):714-7. PubMed ID: 17317379
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of pressure measurement, dobutamine contrast stress echocardiography and SPECT for the evaluation of intermediate coronary stenoses. The COMPRESS trial.
    Rieber J; Jung P; Erhard I; Koenig A; Hacker M; Schiele TM; Segmiller T; Stempfle HU; Theisen K; Siebert U; Klauss V
    Int J Cardiovasc Intervent; 2004; 6(3-4):142-7. PubMed ID: 16146908
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of sulfur hexafluoride microbubble (SonoVue)-enhanced myocardial contrast echocardiography with gated single-photon emission computed tomography for detection of significant coronary artery disease: a large European multicenter study.
    Senior R; Moreo A; Gaibazzi N; Agati L; Tiemann K; Shivalkar B; von Bardeleben S; Galiuto L; Lardoux H; Trocino G; Carrió I; Le Guludec D; Sambuceti G; Becher H; Colonna P; Ten Cate F; Bramucci E; Cohen A; Bezante G; Aggeli C; Kasprzak JD
    J Am Coll Cardiol; 2013 Oct; 62(15):1353-61. PubMed ID: 23770168
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.