These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

109 related articles for article (PubMed ID: 17972454)

  • 1. Oxygenation failure during cardiopulmonary bypass prompts new safety algorithm and training initiative.
    Webb DP; Deegan RJ; Greelish JP; Byrne JG
    J Extra Corpor Technol; 2007 Sep; 39(3):188-91. PubMed ID: 17972454
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A Novel Method to Detect an Oxygenator Defect Prior to Cardiopulmonary Bypass Initiation.
    Fernandes A; Laliberte E; Toledano K; Demers P
    J Extra Corpor Technol; 2015 Sep; 47(3):180-2. PubMed ID: 26543253
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Successful management of membrane oxygenator failure during cardiopulmonary bypass: the importance of safety algorithm and simulation drills.
    Acsell JR
    J Extra Corpor Technol; 2012 Sep; 44(3):164-5. PubMed ID: 23198400
    [No Abstract]   [Full Text] [Related]  

  • 4. Successful management of membrane oxygenator failure during cardiopulmonary bypass--the importance of safety algorithm and simulation drills.
    Soo A; Booth K; Parissis H
    J Extra Corpor Technol; 2012 Jun; 44(2):78-80. PubMed ID: 22893988
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Detection of oxygen delivery failure during cardiopulmonary bypass: an even earlier warning technique.
    Caruso LJ; Gravenstein N; Janelle GM; Gabrielli A
    J Cardiothorac Vasc Anesth; 2002 Dec; 16(6):789. PubMed ID: 12486667
    [No Abstract]   [Full Text] [Related]  

  • 6. Successful management of membrane oxygenator failure during cardiopulmonary bypass--the importance of safety algorithm and simulation drills.
    Hargrove M; Aherne T
    J Extra Corpor Technol; 2012 Sep; 44(3):163. PubMed ID: 23198399
    [No Abstract]   [Full Text] [Related]  

  • 7. Hypothermic Cardiopulmonary Bypass Weaning and Prolonged Postoperative Rewarming in a Patient With Intraoperative Oxygenator Thrombosis.
    Grant I; Breidenstein M; Parsee A; Krumholz C; Martin J
    J Cardiothorac Vasc Anesth; 2018 Aug; 32(4):1851-1854. PubMed ID: 29221982
    [No Abstract]   [Full Text] [Related]  

  • 8. Respiratory dysfunction and white cell activation following cardiopulmonary bypass: comparison of membrane and bubble oxygenators.
    Martin W; Carter R; Tweddel A; Belch J; el-Fiky M; McQuiston AM; McLaren M; Wheatley DJ
    Eur J Cardiothorac Surg; 1996; 10(9):774-83. PubMed ID: 8905281
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Hypoxemia after intraluminal oxygen line obstruction during cardiopulmonary bypass.
    Dickinson TA
    Ann Thorac Surg; 1990 Mar; 49(3):512. PubMed ID: 2310270
    [No Abstract]   [Full Text] [Related]  

  • 10. Oxygenator failure.
    Kurusz M; Conti VR; Arens JF
    Ann Thorac Surg; 1990 Mar; 49(3):511-2. PubMed ID: 2310269
    [No Abstract]   [Full Text] [Related]  

  • 11. Laying the foundation for preventing device-related patient safety problems.
    Pelczarski KM; Heyman J
    Biomed Instrum Technol; 2008; 42(3):225-8. PubMed ID: 18510415
    [No Abstract]   [Full Text] [Related]  

  • 12. Use of Volatile Anesthetic Agent in Extracorporeal Circuit as a Cause of Break in Polycarbonate Connector-Lessons Learnt.
    Gowda D; Rashmi K; Pandarinathan N; Desai N
    J Extra Corpor Technol; 2017 Sep; 49(3):198-200. PubMed ID: 28979044
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Testing potential interference with RFID usage in the patient care environment.
    Christe B; Cooney E; Maggioli G; Doty D; Frye R; Short J
    Biomed Instrum Technol; 2008; 42(6):479-84. PubMed ID: 19012466
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Successful survival from massive air embolism and circulatory arrest during cardio-pulmonary bypass.
    Lin TC; Sia SL; Wong KL; Lai KB; Chuang HI; Sit KF; Wei TT
    Ma Zui Xue Za Zhi; 1992 Dec; 30(4):265-70. PubMed ID: 1344242
    [No Abstract]   [Full Text] [Related]  

  • 15. Identification of human errors during device-related accident investigations.
    Shepherd M; Painter FR; Dyro JF; Baretich MF
    IEEE Eng Med Biol Mag; 2004; 23(3):66-72. PubMed ID: 15354997
    [No Abstract]   [Full Text] [Related]  

  • 16. Parallel replacement of the oxygenator that is not transferring oxygen: the PRONTO procedure.
    Groom RC; Forest RJ; Cormack JE; Niimi KS; Morton J
    Perfusion; 2002 Nov; 17(6):447-50. PubMed ID: 12470036
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Gaseous microemboli: sources, causes, and clinical considerations.
    Kurusz M
    Med Instrum; 1985; 19(2):73-6. PubMed ID: 4000011
    [TBL] [Abstract][Full Text] [Related]  

  • 18. How to leak test bags and flexible products.
    Turner M
    Med Device Technol; 2001 Sep; 12(7):38. PubMed ID: 12938560
    [No Abstract]   [Full Text] [Related]  

  • 19. Complement activation caused by different oxygenators.
    Volanakis JE
    J Thorac Cardiovasc Surg; 1989 Aug; 98(2):292-5. PubMed ID: 2755160
    [No Abstract]   [Full Text] [Related]  

  • 20. Mistake proofing and redundancy in machine validation.
    Blake N
    Med Device Technol; 2003; 14(1):42-5. PubMed ID: 12974126
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.