415 related articles for article (PubMed ID: 17978654)
1. Finite element analysis of anterior lumbar interbody fusion: threaded cylindrical cage and pedicle screw fixation.
Kim Y
Spine (Phila Pa 1976); 2007 Nov; 32(23):2558-68. PubMed ID: 17978654
[TBL] [Abstract][Full Text] [Related]
2. Biomechanical assessment of anterior lumbar interbody fusion with an anterior lumbosacral fixation screw-plate: comparison to stand-alone anterior lumbar interbody fusion and anterior lumbar interbody fusion with pedicle screws in an unstable human cadaver model.
Gerber M; Crawford NR; Chamberlain RH; Fifield MS; LeHuec JC; Dickman CA
Spine (Phila Pa 1976); 2006 Apr; 31(7):762-8. PubMed ID: 16582849
[TBL] [Abstract][Full Text] [Related]
3. In vitro study of biomechanical behavior of anterior and transforaminal lumbar interbody instrumentation techniques.
Niemeyer TK; Koriller M; Claes L; Kettler A; Werner K; Wilke HJ
Neurosurgery; 2006 Dec; 59(6):1271-6; discussion 1276-7. PubMed ID: 17277690
[TBL] [Abstract][Full Text] [Related]
4. Changes in the lumbar foramen following anterior interbody fusion with tapered or cylindrical cages.
Wang M; Dalal S; Bagaria VB; McGrady LM; Rao RD
Spine J; 2007; 7(5):563-9. PubMed ID: 17905318
[TBL] [Abstract][Full Text] [Related]
5. Finite element analysis of the effects of pedicle screw fixation nut loosening on lumbar interbody fusion based on the elasto-plateau plasticity of bone characteristics.
Kim Y; Kim TW
Spine (Phila Pa 1976); 2010 Mar; 35(6):599-606. PubMed ID: 20139810
[TBL] [Abstract][Full Text] [Related]
6. Augmentation of anterior lumbar interbody fusion with anterior pedicle screw fixation: demonstration of novel constructs and evaluation of biomechanical stability in cadaveric specimens.
Karim A; Mukherjee D; Ankem M; Gonzalez-Cruz J; Smith D; Nanda A
Neurosurgery; 2006 Mar; 58(3):522-7; discussion 522-7. PubMed ID: 16528193
[TBL] [Abstract][Full Text] [Related]
7. Enhancing the stability of anterior lumbar interbody fusion: a biomechanical comparison of anterior plate versus posterior transpedicular instrumentation.
Tzermiadianos MN; Mekhail A; Voronov LI; Zook J; Havey RM; Renner SM; Carandang G; Abjornson C; Patwardhan AG
Spine (Phila Pa 1976); 2008 Jan; 33(2):E38-43. PubMed ID: 18197089
[TBL] [Abstract][Full Text] [Related]
8. Biomechanical comparison of anterior lumbar interbody fusion and transforaminal lumbar interbody fusion.
Ploumis A; Wu C; Fischer G; Mehbod AA; Wu W; Faundez A; Transfeldt EE
J Spinal Disord Tech; 2008 Apr; 21(2):120-5. PubMed ID: 18391717
[TBL] [Abstract][Full Text] [Related]
9. Biomechanical comparison of two different concepts for stand alone anterior lumbar interbody fusion.
Schleicher P; Gerlach R; Schär B; Cain CM; Achatz W; Pflugmacher R; Haas NP; Kandziora F
Eur Spine J; 2008 Dec; 17(12):1757-65. PubMed ID: 18841399
[TBL] [Abstract][Full Text] [Related]
10. Computational comparison of anterior lumbar interbody fusion and oblique lumbar interbody fusion with various supplementary fixation systems: a finite element analysis.
Ouyang P; Tan Q; He X; Zhao B
J Orthop Surg Res; 2023 Jan; 18(1):4. PubMed ID: 36593501
[TBL] [Abstract][Full Text] [Related]
11. Types of spinal instability that require interbody support in posterior lumbar reconstruction: an in vitro biomechanical investigation.
Oda I; Abumi K; Yu BS; Sudo H; Minami A
Spine (Phila Pa 1976); 2003 Jul; 28(14):1573-80. PubMed ID: 12865847
[TBL] [Abstract][Full Text] [Related]
12. A new stand-alone cervical anterior interbody fusion device: biomechanical comparison with established anterior cervical fixation devices.
Scholz M; Reyes PM; Schleicher P; Sawa AG; Baek S; Kandziora F; Marciano FF; Crawford NR
Spine (Phila Pa 1976); 2009 Jan; 34(2):156-60. PubMed ID: 19139665
[TBL] [Abstract][Full Text] [Related]
13. Effect of supplemental translaminar facet screw fixation on the stability of stand-alone anterior lumbar interbody fusion cages under physiologic compressive preloads.
Phillips FM; Cunningham B; Carandang G; Ghanayem AJ; Voronov L; Havey RM; Patwardhan AG
Spine (Phila Pa 1976); 2004 Aug; 29(16):1731-6. PubMed ID: 15303015
[TBL] [Abstract][Full Text] [Related]
14. Influence of Dynesys system screw profile on adjacent segment and screw.
Liu CL; Zhong ZC; Shih SL; Hung C; Lee YE; Chen CS
J Spinal Disord Tech; 2010 Aug; 23(6):410-7. PubMed ID: 20683426
[TBL] [Abstract][Full Text] [Related]
15. Segmental stability and compressive strength of posterior lumbar interbody fusion implants.
Tsantrizos A; Baramki HG; Zeidman S; Steffen T
Spine (Phila Pa 1976); 2000 Aug; 25(15):1899-907. PubMed ID: 10908932
[TBL] [Abstract][Full Text] [Related]
16. Biomechanical comparison of anterior lumbar interbody fusion: stand-alone interbody cage versus interbody cage with pedicle screw fixation -- a finite element analysis.
Choi KC; Ryu KS; Lee SH; Kim YH; Lee SJ; Park CK
BMC Musculoskelet Disord; 2013 Jul; 14():220. PubMed ID: 23890389
[TBL] [Abstract][Full Text] [Related]
17. The biomechanical effects of spondylolysis and its treatment.
Mihara H; Onari K; Cheng BC; David SM; Zdeblick TA
Spine (Phila Pa 1976); 2003 Feb; 28(3):235-8. PubMed ID: 12567023
[TBL] [Abstract][Full Text] [Related]
18. Interbody device endplate engagement effects on motion segment biomechanics.
Buttermann GR; Beaubien BP; Freeman AL; Stoll JE; Chappuis JL
Spine J; 2009 Jul; 9(7):564-73. PubMed ID: 19457722
[TBL] [Abstract][Full Text] [Related]
19. Direct lateral approach to lumbar fusion is a biomechanically equivalent alternative to the anterior approach: an in vitro study.
Laws CJ; Coughlin DG; Lotz JC; Serhan HA; Hu SS
Spine (Phila Pa 1976); 2012 May; 37(10):819-25. PubMed ID: 21971125
[TBL] [Abstract][Full Text] [Related]
20. Analysis of pedicle and translaminar facet fixation in a multisegment interbody fusion model.
Eskander M; Brooks D; Ordway N; Dale E; Connolly P
Spine (Phila Pa 1976); 2007 Apr; 32(7):E230-5. PubMed ID: 17414898
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]