These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
88 related articles for article (PubMed ID: 17979442)
1. A high-voltage cardiac stimulator for field shocks of a whole heart in a bath. Mashburn DN; Hinkson SJ; Woods MC; Gilligan JM; Holcomb MR; Wikswo JP Rev Sci Instrum; 2007 Oct; 78(10):104302. PubMed ID: 17979442 [TBL] [Abstract][Full Text] [Related]
2. A percutaneous catheter-based system for the measurement of potential gradients applicable to the study of transthoracic defibrillation. Rosborough JP; Deno DC; Walker RG; Niemann JT Pacing Clin Electrophysiol; 2007 Feb; 30(2):166-74. PubMed ID: 17338711 [TBL] [Abstract][Full Text] [Related]
3. Evaluation of a novel ventricular support device with defibrillation capabilities in canine and porcine animal models. Killingsworth CR; Rippy MK; Virmani R; Rollins DL; McGiffin DC; Ideker RE J Cardiovasc Electrophysiol; 2008 Aug; 19(8):851-7. PubMed ID: 18373602 [TBL] [Abstract][Full Text] [Related]
4. Low-cost computer-controlled current stimulator for the student laboratory. Güçlü B Adv Physiol Educ; 2007 Jun; 31(2):223-31. PubMed ID: 17562915 [TBL] [Abstract][Full Text] [Related]
5. Calibrated current divider network for precision current delivery during high-voltage transthoracic defibrillation. Deale OC; Ng KT; Lerman BB IEEE Trans Biomed Eng; 2005 Nov; 52(11):1970-3. PubMed ID: 16285402 [TBL] [Abstract][Full Text] [Related]
6. Tunable features of magnetoelectric transformers. Dong S; Zhai J; Priya S; Li JF; Viehland D IEEE Trans Ultrason Ferroelectr Freq Control; 2009 Jun; 56(6):1124-7. PubMed ID: 19574118 [TBL] [Abstract][Full Text] [Related]
7. Development of a new arbitrary waveform defibrillator for cardiac electrophysiology research. Triventi M; Mattei E; Delogu A; Censi F; Calcagnini G; Bartolini P; Aguel F; Stohlman J; Krauthamer V Annu Int Conf IEEE Eng Med Biol Soc; 2008; 2008():597-600. PubMed ID: 19162726 [TBL] [Abstract][Full Text] [Related]
8. A novel programmable pulse generator with nanosecond resolution for pulsed electron paramagnetic resonance applications. Devasahayam N; Subramanian S; Krishna MC Rev Sci Instrum; 2008 Feb; 79(2 Pt 1):026106. PubMed ID: 18315338 [TBL] [Abstract][Full Text] [Related]
9. Defibrillation probability and impedance change between shocks during resuscitation from out-of-hospital cardiac arrest. Walker RG; Koster RW; Sun C; Moffat G; Barger J; Dodson PP; Chapman FW Resuscitation; 2009 Jul; 80(7):773-7. PubMed ID: 19423211 [TBL] [Abstract][Full Text] [Related]
10. Timing of defibrillation shocks for resuscitation of rapid ventricular tachycardia: does it make a difference? Turner I; Turner S; Grace AA Resuscitation; 2009 Feb; 80(2):183-8. PubMed ID: 19091453 [TBL] [Abstract][Full Text] [Related]
11. Combined device for measurement of the duration of the cardiac cycle and stimulation synchronized with the cardiac cycle. Mazgalev T Acta Physiol Pharmacol Bulg; 1975; 3-4():65-71. PubMed ID: 1211190 [TBL] [Abstract][Full Text] [Related]
12. The implantable cardioverter-defibrillator lead: principles, progress, and promises. Haqqani HM; Mond HG Pacing Clin Electrophysiol; 2009 Oct; 32(10):1336-53. PubMed ID: 19796348 [TBL] [Abstract][Full Text] [Related]
14. A programmable and portable NMES device for drop foot correction and blood flow assist applications. Breen PP; Corley GJ; O'Keeffe DT; Conway R; Olaighin G Med Eng Phys; 2009 Apr; 31(3):400-8. PubMed ID: 18667351 [TBL] [Abstract][Full Text] [Related]
15. Engineered neuronal circuits shaped and interfaced with carbon nanotube microelectrode arrays. Shein M; Greenbaum A; Gabay T; Sorkin R; David-Pur M; Ben-Jacob E; Hanein Y Biomed Microdevices; 2009 Apr; 11(2):495-501. PubMed ID: 19067173 [TBL] [Abstract][Full Text] [Related]
16. Strategic programming of detection and therapy parameters in implantable cardioverter-defibrillators reduces shocks in primary prevention patients: results from the PREPARE (Primary Prevention Parameters Evaluation) study. Wilkoff BL; Williamson BD; Stern RS; Moore SL; Lu F; Lee SW; Birgersdotter-Green UM; Wathen MS; Van Gelder IC; Heubner BM; Brown ML; Holloman KK; J Am Coll Cardiol; 2008 Aug; 52(7):541-50. PubMed ID: 18687248 [TBL] [Abstract][Full Text] [Related]
17. A comparison of chronaxies for ventricular fibrillation induction, defibrillation, and cardiac stimulation: unexpected findings and their implications. Lawo T; Deneke T; Schrader J; Danilovic D; Wenzel B; Buddensiek M; Muegge A J Cardiovasc Electrophysiol; 2009 Mar; 20(3):307-14. PubMed ID: 19175850 [TBL] [Abstract][Full Text] [Related]
18. Protection circuits for ultrasound applications. Camacho J; Fritsch C IEEE Trans Ultrason Ferroelectr Freq Control; 2008 May; 55(5):1160-4. PubMed ID: 18519225 [TBL] [Abstract][Full Text] [Related]
19. High-field NMR using resistive and hybrid magnets. Gan Z; Kwak HT; Bird M; Cross T; Gor'kov P; Brey W; Shetty K J Magn Reson; 2008 Mar; 191(1):135-40. PubMed ID: 18226940 [TBL] [Abstract][Full Text] [Related]
20. Leadless pacing of the heart using induction technology: a feasibility study. Wieneke H; Konorza T; Erbel R; Kisker E Pacing Clin Electrophysiol; 2009 Feb; 32(2):177-83. PubMed ID: 19170906 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]