These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
4. Application of triangular atomic force microscopy cantilevers to friction measurement with the improved parallel scan method. Wang YL; Zhao XZ Rev Sci Instrum; 2009 Feb; 80(2):023704. PubMed ID: 19256650 [TBL] [Abstract][Full Text] [Related]
5. Cantilever spring constant calibration using laser Doppler vibrometry. Ohler B Rev Sci Instrum; 2007 Jun; 78(6):063701. PubMed ID: 17614610 [TBL] [Abstract][Full Text] [Related]
6. A calibration method for lateral forces for use with colloidal probe force microscopy cantilevers. Quintanilla MA; Goddard DT Rev Sci Instrum; 2008 Feb; 79(2 Pt 1):023701. PubMed ID: 18315299 [TBL] [Abstract][Full Text] [Related]
7. Harnessing bifurcations in tapping-mode atomic force microscopy to calibrate time-varying tip-sample force measurements. Sahin O Rev Sci Instrum; 2007 Oct; 78(10):103707. PubMed ID: 17979428 [TBL] [Abstract][Full Text] [Related]
8. An atomic force microscope tip designed to measure time-varying nanomechanical forces. Sahin O; Magonov S; Su C; Quate CF; Solgaard O Nat Nanotechnol; 2007 Aug; 2(8):507-14. PubMed ID: 18654349 [TBL] [Abstract][Full Text] [Related]
9. Simultaneous normal and shear measurements of nanoconfined liquids in a fiber-based atomic force microscope. Matei G; Jeffery S; Patil S; Khan SH; Pantea M; Pethica JB; Hoffmann PM Rev Sci Instrum; 2008 Feb; 79(2 Pt 1):023706. PubMed ID: 18315304 [TBL] [Abstract][Full Text] [Related]
10. Lateral force calibration: accurate procedures for colloidal probe friction measurements in atomic force microscopy. Chung KH; Pratt JR; Reitsma MG Langmuir; 2010 Jan; 26(2):1386-94. PubMed ID: 19827782 [TBL] [Abstract][Full Text] [Related]
11. Atomic-force-microscope-compatible near-field scanning microwave microscope with separated excitation and sensing probes. Lai K; Ji MB; Leindecker N; Kelly MA; Shen ZX Rev Sci Instrum; 2007 Jun; 78(6):063702. PubMed ID: 17614611 [TBL] [Abstract][Full Text] [Related]
12. Feedback based simultaneous correction of imaging artifacts due to geometrical and mechanical cross-talk and tip-sample stick in atomic force microscopy. Shegaonkar AC; Salapaka SM Rev Sci Instrum; 2007 Oct; 78(10):103706. PubMed ID: 17979427 [TBL] [Abstract][Full Text] [Related]
13. Colloid probes with increased tip height for higher sensitivity in friction force microscopy and less cantilever damping in dynamic force microscopy. Schmutz JE; Schäfer MM; Hölscher H Rev Sci Instrum; 2008 Feb; 79(2 Pt 1):026103. PubMed ID: 18315335 [TBL] [Abstract][Full Text] [Related]
14. Direct measurement of cantilever spring constants and correction for cantilever irregularities using an instrumented indenter. Ying ZC; Reitsma MG; Gates RS Rev Sci Instrum; 2007 Jun; 78(6):063708. PubMed ID: 17614617 [TBL] [Abstract][Full Text] [Related]
16. Topography imaging with a heated atomic force microscope cantilever in tapping mode. Park K; Lee J; Zhang ZM; King WP Rev Sci Instrum; 2007 Apr; 78(4):043709. PubMed ID: 17477672 [TBL] [Abstract][Full Text] [Related]
17. Design of a scanning probe microscope with advanced sample treatment capabilities: An atomic force microscope combined with a miniaturized inductively coupled plasma source. Hund M; Herold H Rev Sci Instrum; 2007 Jun; 78(6):063703. PubMed ID: 17614612 [TBL] [Abstract][Full Text] [Related]
18. Application of integrated SECM ultra-micro-electrode and AFM force probe to biosensor surfaces. Hirata Y; Yabuki S; Mizutani F Bioelectrochemistry; 2004 Jun; 63(1-2):217-24. PubMed ID: 15110275 [TBL] [Abstract][Full Text] [Related]
19. Improved lateral force calibration based on the angle conversion factor in atomic force microscopy. Choi D; Hwang W; Yoon E J Microsc; 2007 Nov; 228(Pt 2):190-9. PubMed ID: 17970919 [TBL] [Abstract][Full Text] [Related]
20. Comparison of different methods to calibrate torsional spring constant and photodetector for atomic force microscopy friction measurements in air and liquid. Pettersson T; Nordgren N; Rutland MW; Feiler A Rev Sci Instrum; 2007 Sep; 78(9):093702. PubMed ID: 17902950 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]