These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
339 related articles for article (PubMed ID: 17980889)
1. Study of a monolithic silica capillary column coated with poly(octadecyl methacrylate) for the reversed-phase liquid chromatographic separation of some polar and non-polar compounds. Núñez O; Ikegami T; Miyamoto K; Tanaka N J Chromatogr A; 2007 Dec; 1175(1):7-15. PubMed ID: 17980889 [TBL] [Abstract][Full Text] [Related]
2. Selectivity comparisons of monolithic silica capillary columns modified with poly(octadecyl methacrylate) and octadecyl moieties for halogenated compounds in reversed-phase liquid chromatography. Soonthorntantikul W; Leepipatpiboon N; Ikegami T; Tanaka N; Nhujak T J Chromatogr A; 2009 Jul; 1216(31):5868-74. PubMed ID: 19560150 [TBL] [Abstract][Full Text] [Related]
3. Study of triacontyl-functionalized monolithic silica capillary column for reversed-phase capillary liquid chromatography. Chen Y; Chen J; Jia L J Chromatogr A; 2009 Mar; 1216(12):2597-600. PubMed ID: 19201000 [TBL] [Abstract][Full Text] [Related]
4. Facile preparation of an alternating copolymer-based high molecular shape-selective organic phase for reversed-phase liquid chromatography. Mallik AK; Noguchi H; Rahman MM; Takafuji M; Ihara H J Chromatogr A; 2018 Jun; 1555():53-61. PubMed ID: 29706403 [TBL] [Abstract][Full Text] [Related]
5. Comparison of monolithic silica and polymethacrylate capillary columns for LC. Moravcová D; Jandera P; Urban J; Planeta J J Sep Sci; 2004 Jul; 27(10-11):789-800. PubMed ID: 15354556 [TBL] [Abstract][Full Text] [Related]
6. Selectivity enhancement for the separation of tocopherols and steroids by integration of highly ordered weak interaction sites along the polymer main chain. Mallik AK; Qiu H; Takafuji M; Ihara H Anal Bioanal Chem; 2012 Jul; 404(1):229-38. PubMed ID: 22699229 [TBL] [Abstract][Full Text] [Related]
7. Preparation of high efficiency and highly retentive monolithic silica capillary columns for reversed-phase chromatography by chemical modification by polymerization of octadecyl methacrylate. Núñez O; Ikegami T; Kajiwara W; Miyamoto K; Horie K; Tanaka N J Chromatogr A; 2007 Jul; 1156(1-2):35-44. PubMed ID: 17188698 [TBL] [Abstract][Full Text] [Related]
9. Monolithic silica xerogel capillary column for separations in capillary LC and pressurized CEC. Qu QS; Wang S; Mangelings D; Wang CY; Yang GJ; Hu XY; Yan C Electrophoresis; 2009 Mar; 30(6):1071-6. PubMed ID: 19309008 [TBL] [Abstract][Full Text] [Related]
10. Repeatability in column preparation of a reversed-phase C18 monolith and its application to separation of tocopherol homologues. Kositarat S; Smith NW; Nacapricha D; Wilairat P; Chaisuwan P Talanta; 2011 Jun; 84(5):1374-8. PubMed ID: 21641454 [TBL] [Abstract][Full Text] [Related]
11. Copolymer-grafted silica phase from a cation-anion monomer pair for enhanced separation in reversed-phase liquid chromatography. Mallik AK; Qiu H; Takafuji M; Ihara H Anal Bioanal Chem; 2014 May; 406(14):3507-15. PubMed ID: 24705959 [TBL] [Abstract][Full Text] [Related]
12. Semi-online nanoflow liquid chromatography/matrix-assisted laser desorption ionization mass spectrometry of synthetic polymers using an octadecylsilyl-modified monolithic silica capillary column. Watanabe T; Nakanishi K; Ozawa T; Kawasaki H; Ute K; Arakawa R Rapid Commun Mass Spectrom; 2010 Jul; 24(13):1835-41. PubMed ID: 20533313 [TBL] [Abstract][Full Text] [Related]
13. Performance of functionalized monolithic silica capillary columns with different mesopore sizes using radical polymerization of octadecyl methacrylate. Hara T; Baron GV; Hata K; Izumi Y; Bamba T; Desmet G J Chromatogr A; 2021 Aug; 1651():462282. PubMed ID: 34144397 [TBL] [Abstract][Full Text] [Related]
14. Chromatographic selectivity of poly(alkyl methacrylate-co-divinylbenzene) monolithic columns for polar aromatic compounds by pressure-driven capillary liquid chromatography. Lin SL; Wang CC; Fuh MR Anal Chim Acta; 2016 Oct; 939():117-127. PubMed ID: 27639150 [TBL] [Abstract][Full Text] [Related]
15. Naphthyl methacrylate-based monolithic column for RP-CEC via hydrophobic and pi interactions. Karenga S; El Rassi Z Electrophoresis; 2010 Mar; 31(6):991-1002. PubMed ID: 20148404 [TBL] [Abstract][Full Text] [Related]
16. Cross-linker effects on the separation efficiency on (poly)methacrylate capillary monolithic columns. Part I. Reversed-phase liquid chromatography. Jandera P; Staňková M; Škeříková V; Urban J J Chromatogr A; 2013 Jan; 1274():97-106. PubMed ID: 23273635 [TBL] [Abstract][Full Text] [Related]
17. Preparation and evaluation of hydrophilic C18 monolithic sorbents for enhanced polar compound retention in liquid chromatography and solid phase extraction. Li Y; Xie X; Lee ML; Chen J J Chromatogr A; 2011 Dec; 1218(48):8608-16. PubMed ID: 22030157 [TBL] [Abstract][Full Text] [Related]
18. The use of silica nanoparticles for gas chromatographic separation. Na N; Cui X; De Beer T; Liu T; Tang T; Sajid M; Ouyang J J Chromatogr A; 2011 Jul; 1218(28):4552-8. PubMed ID: 21652043 [TBL] [Abstract][Full Text] [Related]
19. Impact of pore structural parameters on column performance and resolution of reversed-phase monolithic silica columns for peptides and proteins. Skudas R; Grimes BA; Machtejevas E; Kudirkaite V; Kornysova O; Hennessy TP; Lubda D; Unger KK J Chromatogr A; 2007 Mar; 1144(1):72-84. PubMed ID: 17084406 [TBL] [Abstract][Full Text] [Related]
20. Monolithic stationary phases with incorporated fumed silica nanoparticles. Part II. Polymethacrylate-based monolithic column with "covalently" incorporated modified octadecyl fumed silica nanoparticles for reversed-phase chromatography. Aydoğan C; El Rassi Z J Chromatogr A; 2016 May; 1445():62-7. PubMed ID: 27059396 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]