These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
96 related articles for article (PubMed ID: 17985639)
1. Calculation of dose decrease in a finite phantom of a 192Ir point source. Melchert C; Kohr P; Schmidt R Med Phys; 2007 Oct; 34(10):3943-50. PubMed ID: 17985639 [TBL] [Abstract][Full Text] [Related]
2. A CT-based analytical dose calculation method for HDR 192Ir brachytherapy. Poon E; Verhaegen F Med Phys; 2009 Sep; 36(9):3982-94. PubMed ID: 19810471 [TBL] [Abstract][Full Text] [Related]
3. The collapsed cone algorithm for (192)Ir dosimetry using phantom-size adaptive multiple-scatter point kernels. Tedgren ÅC; Plamondon M; Beaulieu L Phys Med Biol; 2015 Jul; 60(13):5313-23. PubMed ID: 26108232 [TBL] [Abstract][Full Text] [Related]
4. A dosimetric comparison of 169Yb and 192Ir for HDR brachytherapy of the breast, accounting for the effect of finite patient dimensions and tissue inhomogeneities. Lymperopoulou G; Papagiannis P; Angelopoulos A; Karaiskos P; Georgiou E; Baltas D Med Phys; 2006 Dec; 33(12):4583-9. PubMed ID: 17278810 [TBL] [Abstract][Full Text] [Related]
5. Development of a scatter correction technique and its application to HDR 192Ir multicatheter breast brachytherapy. Poon E; Verhaegen F Med Phys; 2009 Aug; 36(8):3703-13. PubMed ID: 19746803 [TBL] [Abstract][Full Text] [Related]
6. Development of a phantom to validate high-dose-rate brachytherapy treatment planning systems with heterogeneous algorithms. Moura ES; Micka JA; Hammer CG; Culberson WS; DeWerd LA; Rostelato ME; Zeituni CA Med Phys; 2015 Apr; 42(4):1566-74. PubMed ID: 25832047 [TBL] [Abstract][Full Text] [Related]
7. A BrachyPhantom for verification of dose calculation of HDR brachytherapy planning system. Austerlitz C; Campos CA Med Phys; 2013 Nov; 40(11):112103. PubMed ID: 24320456 [TBL] [Abstract][Full Text] [Related]
8. Effect of inhomogeneities and source position on dose distribution of nucletron high dose rate Ir-192 brachytherapy source by Monte Carlo simulation. Chandola RM; Tiwari S; Kowar MK; Choudhary V J Cancer Res Ther; 2010; 6(1):54-7. PubMed ID: 20479548 [TBL] [Abstract][Full Text] [Related]
9. A generic high-dose rate (192)Ir brachytherapy source for evaluation of model-based dose calculations beyond the TG-43 formalism. Ballester F; Carlsson Tedgren Å; Granero D; Haworth A; Mourtada F; Fonseca GP; Zourari K; Papagiannis P; Rivard MJ; Siebert FA; Sloboda RS; Smith RL; Thomson RM; Verhaegen F; Vijande J; Ma Y; Beaulieu L Med Phys; 2015 Jun; 42(6):3048-61. PubMed ID: 26127057 [TBL] [Abstract][Full Text] [Related]
10. Accuracy assessment of the superposition principle for evaluating dose distributions of elongated and curved 103Pd and 192Ir brachytherapy sources. Bannon EA; Yang Y; Rivard MJ Med Phys; 2011 Jun; 38(6):2957-63. PubMed ID: 21815369 [TBL] [Abstract][Full Text] [Related]
11. A Monte Carlo calculation of dosimetric parameters of 90Sr/90Y and 192Ir SS sources for intravascular brachytherapy. Wang R; Li XA Med Phys; 2000 Nov; 27(11):2528-35. PubMed ID: 11128305 [TBL] [Abstract][Full Text] [Related]
12. Influence of phantom material and dimensions on experimental 192Ir dosimetry. Carlsson Tedgren A; Carlsson GA Med Phys; 2009 Jun; 36(6):2228-35. PubMed ID: 19610312 [TBL] [Abstract][Full Text] [Related]
13. Correction factors for source strength determination in HDR brachytherapy using the in-phantom method. Ubrich F; Wulff J; Engenhart-Cabillic R; Zink K Z Med Phys; 2014 May; 24(2):138-52. PubMed ID: 24021956 [TBL] [Abstract][Full Text] [Related]
14. Brachytherapy source characterization for improved dose calculations using primary and scatter dose separation. Russell KR; Tedgren AK; Ahnesjö A Med Phys; 2005 Sep; 32(9):2739-52. PubMed ID: 16266087 [TBL] [Abstract][Full Text] [Related]
15. Dosimetric accuracy of a deterministic radiation transport based 192Ir brachytherapy treatment planning system. Part I: single sources and bounded homogeneous geometries. Zourari K; Pantelis E; Moutsatsos A; Petrokokkinos L; Karaiskos P; Sakelliou L; Georgiou E; Papagiannis P Med Phys; 2010 Feb; 37(2):649-61. PubMed ID: 20229874 [TBL] [Abstract][Full Text] [Related]
16. Phantom size in brachytherapy source dosimetric studies. Pérez-Calatayud J; Granero D; Ballester F Med Phys; 2004 Jul; 31(7):2075-81. PubMed ID: 15305460 [TBL] [Abstract][Full Text] [Related]
17. Dosimetric accuracy of a deterministic radiation transport based 192Ir brachytherapy treatment planning system. Part II: Monte Carlo and experimental verification of a multiple source dwell position plan employing a shielded applicator. Petrokokkinos L; Zourari K; Pantelis E; Moutsatsos A; Karaiskos P; Sakelliou L; Seimenis I; Georgiou E; Papagiannis P Med Phys; 2011 Apr; 38(4):1981-92. PubMed ID: 21626931 [TBL] [Abstract][Full Text] [Related]
18. Dosimetric characterization of a novel intracavitary mold applicator for 192Ir high dose rate endorectal brachytherapy treatment. Poon E; Reniers B; Devic S; Vuong T; Verhaegen F Med Phys; 2006 Dec; 33(12):4515-26. PubMed ID: 17278803 [TBL] [Abstract][Full Text] [Related]
19. Dosimetric characterization of an 192Ir brachytherapy source with the Monte Carlo code PENELOPE. Casado FJ; García-Pareja S; Cenizo E; Mateo B; Bodineau C; Galán P Phys Med; 2010; 26(3):132-9. PubMed ID: 20034828 [TBL] [Abstract][Full Text] [Related]
20. The feasibility study and characterization of a two-dimensional diode array in "magic phantom" for high dose rate brachytherapy quality assurance. Espinoza A; Beeksma B; Petasecca M; Fuduli I; Porumb C; Cutajar D; Corde S; Jackson M; Lerch ML; Rosenfeld AB Med Phys; 2013 Nov; 40(11):111702. PubMed ID: 24320410 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]