188 related articles for article (PubMed ID: 17985652)
1. Comment on "Image reconstruction via the finite Hilbert transform of the derivative of the backprojection" [Med. Phys. 34, 2837-2843 (2007)].
Wei Y
Med Phys; 2007 Oct; 34(10):4068-70. PubMed ID: 17985652
[No Abstract] [Full Text] [Related]
2. A two-step Hilbert transform method for 2D image reconstruction.
Noo F; Clackdoyle R; Pack JD
Phys Med Biol; 2004 Sep; 49(17):3903-23. PubMed ID: 15470913
[TBL] [Abstract][Full Text] [Related]
3. [The study of associated reconstruction using MV linear accelerator and cone-beam CT].
Liu ZG; Zhao J; Zhuang TG
Zhongguo Yi Liao Qi Xie Za Zhi; 2006 Jul; 30(4):271-3. PubMed ID: 17039936
[TBL] [Abstract][Full Text] [Related]
4. An extended data function and its generalized backprojection for image reconstruction in helical cone-beam CT.
Zou Y; Pan X
Phys Med Biol; 2004 Nov; 49(22):N383-7. PubMed ID: 15609569
[TBL] [Abstract][Full Text] [Related]
5. Cardiac cone-beam CT volume reconstruction using ART.
Nielsen T; Manzke R; Proksa R; Grass M
Med Phys; 2005 Apr; 32(4):851-60. PubMed ID: 15895567
[TBL] [Abstract][Full Text] [Related]
6. Image reconstruction via the finite Hilbert transform of the derivative of the backprojection.
Zeng GL
Med Phys; 2007 Jul; 34(7):2837-43. PubMed ID: 17821991
[TBL] [Abstract][Full Text] [Related]
7. View-independent reconstruction algorithms for cone beam CT with general saddle trajectory.
Yang H; Li M; Koizumi K; Kudo H
Phys Med Biol; 2006 Aug; 51(15):3865-84. PubMed ID: 16861786
[TBL] [Abstract][Full Text] [Related]
8. Hilbert transform based FBP algorithm for fan-beam CT full and partial scans.
You J; Zeng GL
IEEE Trans Med Imaging; 2007 Feb; 26(2):190-9. PubMed ID: 17304733
[TBL] [Abstract][Full Text] [Related]
9. A unified framework for exact cone-beam reconstruction formulas.
Zhao S; Yu H; Wang G
Med Phys; 2005 Jun; 32(6):1712-21. PubMed ID: 16013729
[TBL] [Abstract][Full Text] [Related]
10. Image reconstruction for the circle and line trajectory.
Katsevich A
Phys Med Biol; 2004 Nov; 49(22):5059-72. PubMed ID: 15609558
[TBL] [Abstract][Full Text] [Related]
11. A local region of interest image reconstruction via filtered backprojection for fan-beam differential phase-contrast computed tomography.
Qi Z; Chen GH
Phys Med Biol; 2007 Sep; 52(18):N417-23. PubMed ID: 17804875
[TBL] [Abstract][Full Text] [Related]
12. A pointwise limit theorem for filtered backprojection in computed tomography.
Ye Y; Zhu J; Wang G
Med Phys; 2003 May; 30(5):816-22. PubMed ID: 12772989
[TBL] [Abstract][Full Text] [Related]
13. Effect of scatter on reconstructed image quality in cone beam computed tomography: evaluation of a scatter-reduction optimisation function.
Malusek A; Seger MM; Sandborg M; Alm Carlsson G
Radiat Prot Dosimetry; 2005; 114(1-3):337-40. PubMed ID: 15933133
[TBL] [Abstract][Full Text] [Related]
14. Theoretically exact backprojection filtration algorithm for multi-segment linear trajectory.
Wu W; Yu H; Cong W; Liu F
Phys Med Biol; 2018 Jan; 63(1):015037. PubMed ID: 29053104
[TBL] [Abstract][Full Text] [Related]
15. A shift-invariant filtered backprojection (FBP) cone-beam reconstruction algorithm for the source trajectory of two concentric circles using an equal weighting scheme.
Zhuang T; Nett BE; Leng S; Chen GH
Phys Med Biol; 2006 Jun; 51(12):3189-210. PubMed ID: 16757871
[TBL] [Abstract][Full Text] [Related]
16. Reconstruction of real tomographic data using algebraic methods.
Gendron D; Goussard Y; Beaudoin G; Soulez G; Cloutier G
Annu Int Conf IEEE Eng Med Biol Soc; 2008; 2008():2717-20. PubMed ID: 19163266
[TBL] [Abstract][Full Text] [Related]
17. A fast forward projection using multithreads for multirays on GPUs in medical image reconstruction.
Chou CY; Chuo YY; Hung Y; Wang W
Med Phys; 2011 Jul; 38(7):4052-65. PubMed ID: 21859004
[TBL] [Abstract][Full Text] [Related]
18. [Auto-shutter of CR/DR images and applications in the post-image processing of PACS].
Gao BB; Zhang JG
Zhongguo Yi Liao Qi Xie Za Zhi; 2006 Mar; 30(2):106-8. PubMed ID: 16830801
[TBL] [Abstract][Full Text] [Related]
19. Universal back-projection algorithm for photoacoustic computed tomography.
Xu M; Wang LV
Phys Rev E Stat Nonlin Soft Matter Phys; 2005 Jan; 71(1 Pt 2):016706. PubMed ID: 15697763
[TBL] [Abstract][Full Text] [Related]
20. Exact BPF and FBP algorithms for nonstandard saddle curves.
Yu H; Zhao S; Ye Y; Wang G
Med Phys; 2005 Nov; 32(11):3305-12. PubMed ID: 16372411
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]