These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Ultrathin versus pediatric instruments for colonoscopy in older female patients: A randomized trial. Nemoto D; Utano K; Endo S; Isohata N; Hewett DG; Togashi K Dig Endosc; 2017 Mar; 29(2):168-174. PubMed ID: 27859645 [TBL] [Abstract][Full Text] [Related]
3. A prospective randomized study of the use of an ultrathin colonoscope versus a pediatric colonoscope in sedation-optional colonoscopy. Sato K; Ito S; Kitagawa T; Hirahata K; Hihara D; Tominaga K; Yasuda I; Maetani I Surg Endosc; 2017 Dec; 31(12):5150-5158. PubMed ID: 28488178 [TBL] [Abstract][Full Text] [Related]
4. Randomized trial of standard versus magnetic endoscope imaging colonoscopes for unsedated colonoscopy. Shergill AK; McQuaid KR; Deleon A; McAnanama M; Shah JN Gastrointest Endosc; 2012 May; 75(5):1031-1036.e1. PubMed ID: 22381532 [TBL] [Abstract][Full Text] [Related]
5. Evaluation of discomfort during colonoscopy with conventional and ultrathin colonoscopes in ulcerative colitis patients. Ogawa T; Ohda Y; Nagase K; Kono T; Tozawa K; Tomita T; Iimuro M; Hida N; Oshima T; Fukui H; Hori K; Watari J; Nakamura S; Miwa H Dig Endosc; 2015 Jan; 27(1):99-105. PubMed ID: 24995962 [TBL] [Abstract][Full Text] [Related]
6. Novel rigidizing overtube for colonoscope stabilization and loop prevention (with video). Wei MT; Hwang JH; Watson RR; Park W; Friedland S Gastrointest Endosc; 2021 Mar; 93(3):740-749. PubMed ID: 32739483 [TBL] [Abstract][Full Text] [Related]
7. Usefulness of a small-caliber, variable-stiffness colonoscope as a backup in patients with difficult or incomplete colonoscopy. Horiuchi A; Nakayama Y; Kajiyama M; Fujii H; Tanaka N Am J Gastroenterol; 2004 Oct; 99(10):1936-40. PubMed ID: 15447752 [TBL] [Abstract][Full Text] [Related]
8. Variable stiffness colonoscopes are associated with less pain during colonoscopy in unsedated patients. Yoshikawa I; Honda H; Nagata K; Kanda K; Yamasaki T; Kume K; Tabaru A; Otsuki M Am J Gastroenterol; 2002 Dec; 97(12):3052-5. PubMed ID: 12492189 [TBL] [Abstract][Full Text] [Related]
9. Use of enteroscope without the overtube in incomplete colonoscopies. Purchiaroni F; Conti S; Valerii G; Costamagna G; Riccioni ME Scand J Gastroenterol; 2020 Jan; 55(1):100-104. PubMed ID: 31852356 [No Abstract] [Full Text] [Related]
10. Colonoscopy using a small-caliber colonoscope with passive-bending after incomplete colonoscopy due to sharp angulation or pain. Sato K; Shigiyama F; Ito S; Kitagawa T; Tominaga K; Suzuki T; Maetani I Surg Endosc; 2013 Nov; 27(11):4171-6. PubMed ID: 23722893 [TBL] [Abstract][Full Text] [Related]
11. Transparent hood attached to the colonoscope: does it really work for all types of colonoscopes? Shida T; Katsuura Y; Teramoto O; Kaiho M; Takano S; Yoshidome H; Miyazaki M Surg Endosc; 2008 Dec; 22(12):2654-8. PubMed ID: 18297353 [TBL] [Abstract][Full Text] [Related]
12. Renewed attention for overtube-assisted colonoscopy to prevent incomplete endoscopic examination of the colon. Moreels TG; Macken EJ; Pelckmans PA Dis Colon Rectum; 2013 Aug; 56(8):1013-8. PubMed ID: 23838871 [TBL] [Abstract][Full Text] [Related]
13. A prospective randomized study on the benefits of a new small-caliber colonoscope. Sato K; Ito S; Shigiyama F; Kitagawa T; Hirahata K; Tominaga K; Maetani I Endoscopy; 2012 Aug; 44(8):746-53. PubMed ID: 22833021 [TBL] [Abstract][Full Text] [Related]
14. Propofol sedation for colonoscopy with a new ultrathin or a standard endoscope: a prospective randomized controlled study. Töx U; Schumacher B; Toermer T; Terheggen G; Mertens J; Holzapfel B; Lehmacher W; Goeser T; Neuhaus H Endoscopy; 2013 Jun; 45(6):439-44. PubMed ID: 23468196 [TBL] [Abstract][Full Text] [Related]
15. Usefulness of a pediatric colonoscope for routine colonoscopy in women who have undergone hysterectomy. Marshall JB; Perez RA; Madsen RW Gastrointest Endosc; 2002 Jun; 55(7):838-41. PubMed ID: 12024137 [TBL] [Abstract][Full Text] [Related]
16. Numerical evaluation of the efficacy of small-caliber colonoscopes in reducing patient pain during a colonoscopy. Zhou D; He X Comput Methods Biomech Biomed Engin; 2019 Jan; 22(1):38-46. PubMed ID: 30398066 [TBL] [Abstract][Full Text] [Related]
17. A prospective trial of variable stiffness colonoscopes with different tip diameters in unsedated patients. Chen PJ; Shih YL; Chu HC; Chang WK; Hsieh TY; Chao YC Am J Gastroenterol; 2008 Jun; 103(6):1365-71. PubMed ID: 18513270 [TBL] [Abstract][Full Text] [Related]
18. Intermediate-length colonoscope needs more training duration than long-length colonoscope. Kim YG; Kim KJ; Yang DH; Ye BD; Byeon JS; Myung SJ; Yang SK; Kim JH Scand J Gastroenterol; 2014 Aug; 49(8):1007-13. PubMed ID: 24957569 [TBL] [Abstract][Full Text] [Related]
19. Ultrathin colonoscope with a diameter of 9.8 mm for total colonoscopy. Okamoto M; Kawabe T; Kato J; Yamaji Y; Ikenoue T; Omata M J Clin Gastroenterol; 2005 Sep; 39(8):679-83. PubMed ID: 16082276 [TBL] [Abstract][Full Text] [Related]
20. Enteroscope without overtube for cecal intubation after an incomplete colonoscopy. Coppola F; Gaia S; Cosimato M; Recchia S Dig Liver Dis; 2011 Jun; 43(6):475-7. PubMed ID: 21334994 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]