These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
150 related articles for article (PubMed ID: 17992808)
21. Cardiac output estimation by multi-beat analysis of the radial arterial blood pressure waveform versus intermittent pulmonary artery thermodilution: a method comparison study in patients treated in the intensive care unit after off-pump coronary artery bypass surgery. Greiwe G; Peters V; Hapfelmeier A; Romagnoli S; Kubik M; Saugel B J Clin Monit Comput; 2020 Aug; 34(4):643-648. PubMed ID: 31456071 [TBL] [Abstract][Full Text] [Related]
22. PulseCO: a less-invasive method to monitor cardiac output from arterial pressure after cardiac surgery. Hamilton TT; Huber LM; Jessen ME Ann Thorac Surg; 2002 Oct; 74(4):S1408-12. PubMed ID: 12400827 [TBL] [Abstract][Full Text] [Related]
23. Comparison of FloTrac cardiac output monitoring system in patients undergoing coronary artery bypass grafting with pulmonary artery cardiac output measurements. Cannesson M; Attof Y; Rosamel P; Joseph P; Bastien O; Lehot JJ Eur J Anaesthesiol; 2007 Oct; 24(10):832-9. PubMed ID: 17666154 [TBL] [Abstract][Full Text] [Related]
24. Noninvasive assessment of cardiac output in critically ill patients by analysis of the finger blood pressure waveform. Hirschl MM; Binder M; Gwechenberger M; Herkner H; Bur A; Kittler H; Laggner AN Crit Care Med; 1997 Nov; 25(11):1909-14. PubMed ID: 9366778 [TBL] [Abstract][Full Text] [Related]
25. Arterial pressure waveform derived cardiac output FloTrac/Vigileo system (third generation software): comparison of two monitoring sites with the thermodilution cardiac output. Vasdev S; Chauhan S; Choudhury M; Hote MP; Malik M; Kiran U J Clin Monit Comput; 2012 Apr; 26(2):115-20. PubMed ID: 22350311 [TBL] [Abstract][Full Text] [Related]
30. Pulse contour cardiac output in surgical intensive care unit patients. Tannenbaum GA; Mathews D; Weissman C J Clin Anesth; 1993; 5(6):471-8. PubMed ID: 8123273 [TBL] [Abstract][Full Text] [Related]
31. Comparison between an uncalibrated pulse contour method and thermodilution technique for cardiac output estimation in septic patients. Franchi F; Silvestri R; Cubattoli L; Taccone FS; Donadello K; Romano SM; Giomarelli P; McBride WT; Scolletta S Br J Anaesth; 2011 Aug; 107(2):202-8. PubMed ID: 21665901 [TBL] [Abstract][Full Text] [Related]
32. FloTracĀ® monitoring system: what are its uses in critically ill medical patients? Argueta E; Berdine G; Pena C; Nugent KM Am J Med Sci; 2015 Apr; 349(4):352-6. PubMed ID: 25584624 [TBL] [Abstract][Full Text] [Related]
34. Estimation of changes in cardiac output from the arterial blood pressure waveform in the upper limb. Linton NW; Linton RA Br J Anaesth; 2001 Apr; 86(4):486-96. PubMed ID: 11573621 [TBL] [Abstract][Full Text] [Related]
35. Uncalibrated arterial pressure waveform analysis for cardiac output monitoring is biased by low peripheral resistance in patients with intracranial haemorrhage. Junttila EK; Koskenkari JK; Ohtonen PP; Ala-Kokko TI Br J Anaesth; 2011 Oct; 107(4):581-6. PubMed ID: 21693470 [TBL] [Abstract][Full Text] [Related]
36. Reliability of Cardiac Output Measurements Using LiDCOrapid and Calibration by Transesophageal Echocardiography With the Continuous Pulmonary Artery Thermodilution Method in Patients Undergoing Aortic Valve Replacement for Aortic Stenosis. Sato M; Kunisawa T J Cardiothorac Vasc Anesth; 2018 Dec; 32(6):2495-2502. PubMed ID: 29801725 [TBL] [Abstract][Full Text] [Related]
37. Cardiac output and stroke volume variation measured by the pulse wave transit time method: a comparison with an arterial pressure-based cardiac output system. Suzuki T; Suzuki Y; Okuda J; Minoshima R; Misonoo Y; Ueda T; Kato J; Nagata H; Yamada T; Morisaki H J Clin Monit Comput; 2019 Jun; 33(3):385-392. PubMed ID: 29948667 [TBL] [Abstract][Full Text] [Related]
38. Continuous cardiac output monitoring in humans by invasive and noninvasive peripheral blood pressure waveform analysis. Lu Z; Mukkamala R J Appl Physiol (1985); 2006 Aug; 101(2):598-608. PubMed ID: 16849813 [TBL] [Abstract][Full Text] [Related]
40. Continuous registration of cardiac output with a new computer system designed for hot-film anemometry: an in vitro study. Hasenkam JM; Ostergaard JH; Pedersen EM; Paulsen PK; Nissen T Life Support Syst; 1986; 4(4):335-44. PubMed ID: 2951566 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]