BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

227 related articles for article (PubMed ID: 17997205)

  • 21. Mechanical characterization of external fixator stiffness for a rat femoral fracture model.
    Willie B; Adkins K; Zheng X; Simon U; Claes L
    J Orthop Res; 2009 May; 27(5):687-93. PubMed ID: 18985701
    [TBL] [Abstract][Full Text] [Related]  

  • 22. [Biomechanics of external fixation devices and optimal tactics for treating long bone fractures].
    Karlov AV; Lichatschov VN
    Biomed Tech (Berl); 1997; 42 Suppl():89-90. PubMed ID: 9517060
    [No Abstract]   [Full Text] [Related]  

  • 23. [Surgical treatment of tibia plateau fractures with external fixator and the locking plate].
    Tian K; Duanmu QL; Ni LZ; Huang DH; Mei ZF; Qu HB; Lei WT; Zhu H; Han YT; Ma W; Zhao QH
    Zhongguo Gu Shang; 2009 Aug; 22(8):618-20. PubMed ID: 19753987
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Management of tibial fractures with Orthofix axial external skeletal fixator in 15 dogs.
    Gül NY; Yanik K
    Vet Comp Orthop Traumatol; 2006; 19(4):228-35. PubMed ID: 17143395
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Hardware removal after tibial fracture has healed.
    Sidky A; Buckley RE
    Can J Surg; 2008 Aug; 51(4):263-8. PubMed ID: 18815648
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Efficacy of monitoring long-bone fracture healing by measurement of either bone stiffness or resonant frequency: numerical simulation.
    Roberts SG; Steele CR
    J Orthop Res; 2000 Sep; 18(5):691-7. PubMed ID: 11117288
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Percutaneous autologous bone marrow grafting on the site of tibial delayed union.
    Sebecić B; Gabelica V; Patrlj L; Sosa T
    Croat Med J; 1999 Sep; 40(3):429-32. PubMed ID: 10411974
    [TBL] [Abstract][Full Text] [Related]  

  • 28. [Computerized sonometry--use of a noninvasive procedure for evaluating stability after fractures].
    Fellinger M; Schanner A; Szyszkowitz R; Leitgeb N; Stockenhuber N; Roupec R
    Aktuelle Traumatol; 1993 Aug; 23(5):235-8. PubMed ID: 7901977
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Compartment syndrome in Schatzker type VI plateau fractures and medial condylar fracture-dislocations treated with temporary external fixation.
    Stark E; Stucken C; Trainer G; Tornetta P
    J Orthop Trauma; 2009 Aug; 23(7):502-6. PubMed ID: 19633459
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [Stress shielding and fracture healing].
    Liu JG; Xu XX
    Zhonghua Yi Xue Za Zhi; 1994 Aug; 74(8):483-5, 519. PubMed ID: 7994658
    [TBL] [Abstract][Full Text] [Related]  

  • 31. The role of osteogenic index, octahedral shear stress and dilatational stress in the ossification of a fracture callus.
    Gardner TN; Mishra S; Marks L
    Med Eng Phys; 2004 Jul; 26(6):493-501. PubMed ID: 15234685
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Torsional stiffness in healing fractures: influence of ossification: an experimental study in rats.
    Mark H; Rydevik B
    Acta Orthop; 2005 Jun; 76(3):428-33. PubMed ID: 16156474
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Mechanical induction of critically delayed bone healing in sheep: radiological and biomechanical results.
    Schell H; Thompson MS; Bail HJ; Hoffmann JE; Schill A; Duda GN; Lienau J
    J Biomech; 2008 Oct; 41(14):3066-72. PubMed ID: 18778822
    [TBL] [Abstract][Full Text] [Related]  

  • 34. In vivo axial load-share ratio measurement using a novel hexapod system for safe external fixator removal.
    Liu S; Lu L; Chen T; Liu Y; Wei D; Miao J; Yu D; Fu X
    BMC Musculoskelet Disord; 2024 May; 25(1):353. PubMed ID: 38724941
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Management of tibial fractures using a circular external fixator in two calves.
    Aithal HP; Kinjavdekar P; Amarpal ; Pawde AM; Singh GR; Setia HC
    Vet Surg; 2010 Jul; 39(5):621-6. PubMed ID: 20636557
    [TBL] [Abstract][Full Text] [Related]  

  • 36. [Case-clinical studies on the applicator of external fixator in the open tibia and fibula fractured patients with multiple trauma].
    Wang CQ; Li Q; Liu G; Deng J
    Zhongguo Gu Shang; 2008 Jun; 21(6):417-8. PubMed ID: 19108421
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Use of a circular external skeletal fixator to treat comminuted metacarpal and tibial fractures in six calves.
    Bilgili H; Kurum B; Captug O
    Vet Rec; 2008 Dec; 163(23):683-7. PubMed ID: 19060317
    [TBL] [Abstract][Full Text] [Related]  

  • 38. The role of fixator frame stiffness in the control of fracture healing. An experimental study.
    Goodship AE; Watkins PE; Rigby HS; Kenwright J
    J Biomech; 1993 Sep; 26(9):1027-35. PubMed ID: 8408085
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Mechanical influences on tibial fracture healing.
    Kenwright J; Gardner T
    Clin Orthop Relat Res; 1998 Oct; (355 Suppl):S179-90. PubMed ID: 9917638
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Fracture stiffness as a guide to the management of tibial fractures.
    Wade RH; Moorcroft CI; Thomas PB
    J Bone Joint Surg Br; 2001 May; 83(4):533-5. PubMed ID: 11380125
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 12.