194 related articles for article (PubMed ID: 1799740)
1. Clover leaf inferior vena cava filter: in vitro evaluation of filter deployment and comparison of emboli-capturing ability.
Palestrant AM; Faykus MH
J Vasc Interv Radiol; 1991 Feb; 2(1):117-21. PubMed ID: 1799740
[TBL] [Abstract][Full Text] [Related]
2. Experimental comparison of percutaneous vena caval devices: titanium Greenfield filter versus bird's nest filter.
Burke PE; Michna BA; Harvey CF; Crute SL; Sobel M; Greenfield LJ
J Vasc Surg; 1987 Jul; 6(1):66-70. PubMed ID: 3599283
[TBL] [Abstract][Full Text] [Related]
3. In vitro and in vivo experimental evaluation of a new vena caval filter.
Qian Z; Yasui K; Nazarian GK; Vlodaver Z; Hunter DW; Castaneda-Zuniga WR; Amplatz K
J Vasc Interv Radiol; 1994; 5(3):513-8. PubMed ID: 8054757
[TBL] [Abstract][Full Text] [Related]
4. Comparative evaluation of clinically available inferior vena cava filters with an in vitro physiologic simulation of the vena cava.
Simon M; Rabkin DJ; Kleshinski S; Kim D; Ransil BJ
Radiology; 1993 Dec; 189(3):769-74. PubMed ID: 8234702
[TBL] [Abstract][Full Text] [Related]
5. In vitro study of guide wire entrapment in currently available inferior vena cava filters.
Stavropoulos SW; Itkin M; Trerotola SO
J Vasc Interv Radiol; 2003 Jul; 14(7):905-10. PubMed ID: 12847198
[TBL] [Abstract][Full Text] [Related]
6. The bird's nest filter: a new percutaneous transcatheter inferior vena cava filter.
Roehm JO
J Vasc Surg; 1984 May; 1(3):498-501. PubMed ID: 6481901
[TBL] [Abstract][Full Text] [Related]
7. Retrievable IVC square stent filter: experimental study.
Pavcnik D; Uchida BT; Keller FS; Corless CL; Rösch J
Cardiovasc Intervent Radiol; 1999; 22(3):239-45. PubMed ID: 10382057
[TBL] [Abstract][Full Text] [Related]
8. Acute clot-trapping efficiency in dogs with compacted versus elongated wires in bird's nest filters.
Carlson JE; Yedlicka JW; Castaneda-Zuniga WR; Hunter DW; Amplatz K
J Vasc Interv Radiol; 1993; 4(4):513-6. PubMed ID: 8353348
[TBL] [Abstract][Full Text] [Related]
9. The bird's nest inferior vena cava filter: progress report.
Roehm JO; Johnsrude IS; Barth MH; Gianturco C
Radiology; 1988 Sep; 168(3):745-9. PubMed ID: 3043548
[TBL] [Abstract][Full Text] [Related]
10. Temporary use of a Bird's Nest filter during iliocaval thrombolysis.
Cope C; Baum RA; Duszak RA
Radiology; 1996 Mar; 198(3):765-7. PubMed ID: 8628868
[TBL] [Abstract][Full Text] [Related]
11. Inferior vena cava filters. Indications, safety, effectiveness.
Becker DM; Philbrick JT; Selby JB
Arch Intern Med; 1992 Oct; 152(10):1985-94. PubMed ID: 1417371
[TBL] [Abstract][Full Text] [Related]
12. In vitro evaluation of clot capture efficiency of an absorbable vena cava filter.
Dria SJ; Eggers MD
J Vasc Surg Venous Lymphat Disord; 2016 Oct; 4(4):472-8. PubMed ID: 27639002
[TBL] [Abstract][Full Text] [Related]
13. Numerical analysis of the hemodynamics and embolus capture of a greenfield vena cava filter.
Swaminathan TN; Hu HH; Patel AA
J Biomech Eng; 2006 Jun; 128(3):360-70. PubMed ID: 16706585
[TBL] [Abstract][Full Text] [Related]
14. Percutaneously placed inferior vena cava filter for the prevention of pulmonary emboli: a plea for early insertion.
Rubio PA
Int Surg; 1993; 78(4):328-31. PubMed ID: 8175262
[TBL] [Abstract][Full Text] [Related]
15. Multiple emboli and filter function: an in vitro comparison of three vena cava filters.
Xian ZY; Roy S; Hosaka J; Kvernebo K; Laerum F
J Vasc Interv Radiol; 1995; 6(6):887-93. PubMed ID: 8850665
[TBL] [Abstract][Full Text] [Related]
16. Case report: structural failure of a bird's nest inferior vena caval filter.
Perry JN; Wells IP
Clin Radiol; 1994 Jun; 49(6):431-2. PubMed ID: 8045073
[TBL] [Abstract][Full Text] [Related]
17. Perforation of the heart by an inferior vena cava filter.
Bolton JW; Aldea GS
Mil Med; 1994 Apr; 159(4):360-2. PubMed ID: 20058439
[TBL] [Abstract][Full Text] [Related]
18. Comparison of filters in an oversized vena caval phantom: intracaval placement of a bird's nest filter versus biiliac placement of Greenfield, Vena Tech-LGM, and Simon nitinol filters.
Korbin CD; Reed RA; Taylor FC; Pentecost MJ; Teitelbaum GP
J Vasc Interv Radiol; 1992 Aug; 3(3):559-64. PubMed ID: 1515730
[TBL] [Abstract][Full Text] [Related]
19. Strut interlocking of titanium Greenfield vena cava filters and its effect on clot capturing: an in vitro study.
Korbin CD; Van Allan RJ; Andrews RT; Katz MD; Teitelbaum GP
Cardiovasc Intervent Radiol; 1994; 17(4):204-6. PubMed ID: 7954574
[TBL] [Abstract][Full Text] [Related]
20. [Vena cava filter for prevention of pulmonary embolism].
Winkler WB; Slany J
Vasa; 1999 Nov; 28(4):250-8. PubMed ID: 10611842
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]