These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

129 related articles for article (PubMed ID: 18000870)

  • 21. Wear properties of alumina/zirconia composite ceramics for joint prostheses measured with an end-face apparatus.
    Morita Y; Nakata K; Kim YH; Sekino T; Niihara K; Ikeuchi K
    Biomed Mater Eng; 2004; 14(3):263-70. PubMed ID: 15299238
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Wear and deformation of ceramic-on-polyethylene total hip replacements with joint laxity and swing phase microseparation.
    Williams S; Butterfield M; Stewart T; Ingham E; Stone M; Fisher J
    Proc Inst Mech Eng H; 2003; 217(2):147-53. PubMed ID: 12666782
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Wear characteristics of ceramic-on-ceramic for hip endoprostheses.
    Früh HJ; Willmann G; Pfaff HG
    Biomaterials; 1997 Jun; 18(12):873-6. PubMed ID: 9184751
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Effect of surface treatments on the properties and morphological change of dental zirconia.
    Hallmann L; Ulmer P; Wille S; Polonskyi O; Köbel S; Trottenberg T; Bornholdt S; Haase F; Kersten H; Kern M
    J Prosthet Dent; 2016 Mar; 115(3):341-9. PubMed ID: 26581661
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Effects of aging procedures on the topographic surface, structural stability, and mechanical strength of a ZrO2-based dental ceramic.
    Cotes C; Arata A; Melo RM; Bottino MA; Machado JP; Souza RO
    Dent Mater; 2014 Dec; 30(12):e396-404. PubMed ID: 25244926
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Effect of protein lubrication on the wear properties of materials for prosthetic joints.
    Liao YS; Benya PD; McKellop HA
    J Biomed Mater Res; 1999; 48(4):465-73. PubMed ID: 10421688
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Wear Characteristics and Volume Loss of CAD/CAM Ceramic Materials.
    Zurek AD; Alfaro MF; Wee AG; Yuan JC; Barao VA; Mathew MT; Sukotjo C
    J Prosthodont; 2019 Feb; 28(2):e510-e518. PubMed ID: 29508487
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Are PEEK-on-Ceramic Bearings an Option for Total Disc Arthroplasty? An In Vitro Tribology Study.
    Siskey R; Ciccarelli L; Lui MK; Kurtz SM
    Clin Orthop Relat Res; 2016 Nov; 474(11):2428-2440. PubMed ID: 27677290
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Effect of in vitro aging on the flexural strength and probability to fracture of Y-TZP zirconia ceramics for all-ceramic restorations.
    Siarampi E; Kontonasaki E; Andrikopoulos KS; Kantiranis N; Voyiatzis GA; Zorba T; Paraskevopoulos KM; Koidis P
    Dent Mater; 2014 Dec; 30(12):e306-16. PubMed ID: 24993809
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Effect of heat treatment and in vitro aging on the microstructure and mechanical properties of cold isostatic-pressed zirconia ceramics for dental restorations.
    Vatali A; Kontonasaki E; Kavouras P; Kantiranis N; Papadopoulou L; Paraskevopoulos KK; Koidis P
    Dent Mater; 2014 Oct; 30(10):e272-82. PubMed ID: 24950805
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Effect of polishing procedures and hydrothermal aging on wear characteristics and phase transformation of zirconium dioxide.
    Bartolo D; Cassar G; Al-Haj Husain N; Özcan M; Camilleri J
    J Prosthet Dent; 2017 Apr; 117(4):545-551. PubMed ID: 27881307
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Innovative tribometer for in situ spectroscopic analyses of wear mechanisms and phase transformation in ceramic femoral heads.
    Puppulin L; Leto A; Wenliang Z; Sugano N; Pezzotti G
    J Mech Behav Biomed Mater; 2014 Mar; 31():45-54. PubMed ID: 23453272
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Influence of hydrothermal and mechanical conditions on the strength of zirconia.
    Borchers L; Stiesch M; Bach FW; Buhl JC; Hübsch C; Kellner T; Kohorst P; Jendras M
    Acta Biomater; 2010 Dec; 6(12):4547-52. PubMed ID: 20656076
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Edge loading does not increase wear rates of ceramic-on-ceramic and metal-on-polyethylene articulations.
    Halma JJ; Señaris J; Delfosse D; Lerf R; Oberbach T; van Gaalen SM; de Gast A
    J Biomed Mater Res B Appl Biomater; 2014 Nov; 102(8):1627-38. PubMed ID: 24652696
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Zirconia Phase Transformation in Zirconia-Toughened Alumina Ceramic Femoral Heads: An Implant Retrieval Analysis.
    Nguyen TM; Weitzler L; Esposito CI; Porporati AA; Padgett DE; Wright TM
    J Arthroplasty; 2019 Dec; 34(12):3094-3098. PubMed ID: 31405633
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Failures of yttria-stabilised tetragonal zirconia: 52 retrieved ceramic femoral heads of total hip prostheses.
    Fernández-Fairén M; Sala P; Gil FJ
    Biomed Mater Eng; 2006; 16(6):415-22. PubMed ID: 17119280
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Chemically driven tetragonal-to-monoclinic polymorphic transformation in retrieved ZTA femoral heads from dual mobility hip implants.
    Boffelli M; Doimo A; Marin E; Puppulin L; Zhu W; Sugano N; Clarke IC; Pezzotti G
    J Mech Behav Biomed Mater; 2016 Mar; 56():195-204. PubMed ID: 26708254
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Hydrothermal degradation of a 3Y-TZP translucent dental ceramic: A comparison of numerical predictions with experimental data after 2 years of aging.
    Cattani-Lorente M; Durual S; Amez-Droz M; Wiskott HW; Scherrer SS
    Dent Mater; 2016 Mar; 32(3):394-402. PubMed ID: 26777095
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Effect of sandblasting on the mechanical properties of Y-TZP zirconia.
    Bhargava S; Doi H; Kondo R; Aoki H; Hanawa T; Kasugai S
    Biomed Mater Eng; 2012; 22(6):383-98. PubMed ID: 23114467
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Clinical wear behaviour of ultra-high molecular weight polyethylene cups paired with metal and ceramic ball heads in comparison to metal-on-metal pairings of hip joint replacements.
    Semlitsch M; Willert HG
    Proc Inst Mech Eng H; 1997; 211(1):73-88. PubMed ID: 9141893
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.