164 related articles for article (PubMed ID: 18001917)
1. Microprobe array with low impedance electrodes and highly flexible polyimide cables for acute neural recording.
Kisban S; Herwik S; Seidl K; Rubehn B; Jezzini A; Umiltà MA; Fogassi L; Stieglitz T; Paul O; Ruther P
Annu Int Conf IEEE Eng Med Biol Soc; 2007; 2007():175-8. PubMed ID: 18001917
[TBL] [Abstract][Full Text] [Related]
2. Polyimide cuff electrodes for peripheral nerve stimulation.
Rodríguez FJ; Ceballos D; Schüttler M; Valero A; Valderrama E; Stieglitz T; Navarro X
J Neurosci Methods; 2000 Jun; 98(2):105-18. PubMed ID: 10880824
[TBL] [Abstract][Full Text] [Related]
3. Polymer-based interconnection cables to integrate with flexible penetrating microelectrode arrays.
Oh K; Byun D; Kim S
Biomed Microdevices; 2017 Aug; 19(4):76. PubMed ID: 28842779
[TBL] [Abstract][Full Text] [Related]
4. Large-scale recording of neurons by movable silicon probes in behaving rodents.
Vandecasteele M; M S; Royer S; Belluscio M; Berényi A; Diba K; Fujisawa S; Grosmark A; Mao D; Mizuseki K; Patel J; Stark E; Sullivan D; Watson B; Buzsáki G
J Vis Exp; 2012 Mar; (61):e3568. PubMed ID: 22415550
[TBL] [Abstract][Full Text] [Related]
5. Development of flexible microelectrode arrays for recording cortical surface field potentials.
Myllymaa S; Myllymaa K; Korhonen H; Gureviciene I; Djupsund K; Tanila H; Lappalainen R
Annu Int Conf IEEE Eng Med Biol Soc; 2008; 2008():3200-3. PubMed ID: 19163387
[TBL] [Abstract][Full Text] [Related]
6. Design and fabrication of a polyimide-based microelectrode array: application in neural recording and repeatable electrolytic lesion in rat brain.
Chen YY; Lai HY; Lin SH; Cho CW; Chao WH; Liao CH; Tsang S; Chen YF; Lin SY
J Neurosci Methods; 2009 Aug; 182(1):6-16. PubMed ID: 19467262
[TBL] [Abstract][Full Text] [Related]
7. Insertion shuttle with carboxyl terminated self-assembled monolayer coatings for implanting flexible polymer neural probes in the brain.
Kozai TD; Kipke DR
J Neurosci Methods; 2009 Nov; 184(2):199-205. PubMed ID: 19666051
[TBL] [Abstract][Full Text] [Related]
8. Fabrication and characterization of polyimide-based 'smooth' titanium nitride microelectrode arrays for neural stimulation and recording.
Rodrigues F; Ribeiro JF; Anacleto PA; Fouchard A; David O; Sarro PM; Mendes PM
J Neural Eng; 2019 Dec; 17(1):016010. PubMed ID: 31614339
[TBL] [Abstract][Full Text] [Related]
9. Microelectrode array on folding polyimide ribbon for epidural mapping of functional evoked potentials.
Takahashi H; Ejiri T; Nakao M; Nakamura N; Kaga K; Hervé T
IEEE Trans Biomed Eng; 2003 Apr; 50(4):510-6. PubMed ID: 12723063
[TBL] [Abstract][Full Text] [Related]
10. Improved polyimide thin-film electrodes for neural implants.
Ordonez JS; Boehler C; Schuettler M; Stieglitz T
Annu Int Conf IEEE Eng Med Biol Soc; 2012; 2012():5134-7. PubMed ID: 23367084
[TBL] [Abstract][Full Text] [Related]
11. Versatile, modular 3D microelectrode arrays for neuronal ensemble recordings: from design to fabrication, assembly, and functional validation in non-human primates.
Barz F; Livi A; Lanzilotto M; Maranesi M; Bonini L; Paul O; Ruther P
J Neural Eng; 2017 Jun; 14(3):036010. PubMed ID: 28102825
[TBL] [Abstract][Full Text] [Related]
12. Flexible polyimide probes with microelectrodes and embedded microfluidic channels for simultaneous drug delivery and multi-channel monitoring of bioelectric activity.
Metz S; Bertsch A; Bertrand D; Renaud P
Biosens Bioelectron; 2004 May; 19(10):1309-18. PubMed ID: 15046764
[TBL] [Abstract][Full Text] [Related]
13. Silicon ribbon cables for chronically implantable microelectrode arrays.
Hetke JF; Lund JL; Najafi K; Wise KD; Anderson DJ
IEEE Trans Biomed Eng; 1994 Apr; 41(4):314-21. PubMed ID: 8063297
[TBL] [Abstract][Full Text] [Related]
14. PEDOT-CNT-Coated Low-Impedance, Ultra-Flexible, and Brain-Conformable Micro-ECoG Arrays.
Castagnola E; Maiolo L; Maggiolini E; Minotti A; Marrani M; Maita F; Pecora A; Angotzi GN; Ansaldo A; Boffini M; Fadiga L; Fortunato G; Ricci D
IEEE Trans Neural Syst Rehabil Eng; 2015 May; 23(3):342-50. PubMed ID: 25073174
[TBL] [Abstract][Full Text] [Related]
15. Chronic neural probe for simultaneous recording of single-unit, multi-unit, and local field potential activity from multiple brain sites.
Pothof F; Bonini L; Lanzilotto M; Livi A; Fogassi L; Orban GA; Paul O; Ruther P
J Neural Eng; 2016 Aug; 13(4):046006. PubMed ID: 27247248
[TBL] [Abstract][Full Text] [Related]
16. Polytrodes: high-density silicon electrode arrays for large-scale multiunit recording.
Blanche TJ; Spacek MA; Hetke JF; Swindale NV
J Neurophysiol; 2005 May; 93(5):2987-3000. PubMed ID: 15548620
[TBL] [Abstract][Full Text] [Related]
17. Durability of high surface area platinum deposits on microelectrode arrays for acute neural recordings.
Márton G; Bakos I; Fekete Z; Ulbert I; Pongrácz A
J Mater Sci Mater Med; 2014 Mar; 25(3):931-40. PubMed ID: 24318022
[TBL] [Abstract][Full Text] [Related]
18. Toward a comparison of microelectrodes for acute and chronic recordings.
Ward MP; Rajdev P; Ellison C; Irazoqui PP
Brain Res; 2009 Jul; 1282():183-200. PubMed ID: 19486899
[TBL] [Abstract][Full Text] [Related]
19. A flexible perforated microelectrode array probe for action potential recording in nerve and muscle tissues.
González C; Rodríguez M
J Neurosci Methods; 1997 Apr; 72(2):189-95. PubMed ID: 9133584
[TBL] [Abstract][Full Text] [Related]
20. A photosensitive polyimide based method for an easy fabrication of multichannel neural electrodes.
Kato YX; Maki K; Furukawa S; Kashino M
Annu Int Conf IEEE Eng Med Biol Soc; 2008; 2008():5802-5. PubMed ID: 19164036
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]