These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
123 related articles for article (PubMed ID: 18002261)
1. On the reliability of pulse oximetry at the sternum. Solà J; Chételat O; Krauss J Annu Int Conf IEEE Eng Med Biol Soc; 2007; 2007():1537. PubMed ID: 18002261 [TBL] [Abstract][Full Text] [Related]
2. Development of an implantable pulse oximeter. Reichelt S; Fiala J; Werber A; Förster K; Heilmann C; Klemm R; Zappe H IEEE Trans Biomed Eng; 2008 Feb; 55(2 Pt 1):581-8. PubMed ID: 18269993 [TBL] [Abstract][Full Text] [Related]
3. Optical fibre sensors embedded into technical textile for a continuous monitoring of patients under Magnetic Resonance Imaging. De Jonckheere J; Narbonneau F; Kinet D; Zinke J; Paquet B; Depre A; Jeanne M; Logier R Annu Int Conf IEEE Eng Med Biol Soc; 2008; 2008():5266-9. PubMed ID: 19163905 [TBL] [Abstract][Full Text] [Related]
4. A wearable reflectance pulse oximeter for remote physiological monitoring. Mendelson Y; Duckworth RJ; Comtois G Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():912-5. PubMed ID: 17946007 [TBL] [Abstract][Full Text] [Related]
6. Evaluation of a new combined transcutaneous measurement of PCO2/pulse oximetry oxygen saturation ear sensor in newborn patients. Bernet-Buettiker V; Ugarte MJ; Frey B; Hug MI; Baenziger O; Weiss M Pediatrics; 2005 Jan; 115(1):e64-8. PubMed ID: 15601814 [TBL] [Abstract][Full Text] [Related]
7. Pulse oximetry using a disposable finger sensor placed on the forehead in hypoxic patients. Smithline HA; Rudnitzky N; Macomber S; Blank FS J Emerg Med; 2010 Jul; 39(1):121-5. PubMed ID: 19406607 [TBL] [Abstract][Full Text] [Related]
8. Development of easy operating arterial stiffness assessment instrument for home care. Wu HT; Yao CT; Wu TC; Liu AB Annu Int Conf IEEE Eng Med Biol Soc; 2007; 2007():5869-72. PubMed ID: 18003349 [TBL] [Abstract][Full Text] [Related]
9. Clinical investigation of a new combined pulse oximetry and carbon dioxide tension sensor in adult anaesthesia. Rohling R; Biro P J Clin Monit Comput; 1999 Jan; 15(1):23-7. PubMed ID: 12578058 [TBL] [Abstract][Full Text] [Related]
10. Lightweight physiologic sensor performance during pre-hospital care delivered by ambulance clinicians. Mort AJ; Fitzpatrick D; Wilson PM; Mellish C; Schneider A J Clin Monit Comput; 2016 Feb; 30(1):23-32. PubMed ID: 25804608 [TBL] [Abstract][Full Text] [Related]
11. LED power reduction trade-offs for ambulatory pulse oximetry. Peláez EA; Villegas ER Annu Int Conf IEEE Eng Med Biol Soc; 2007; 2007():2296-9. PubMed ID: 18002450 [TBL] [Abstract][Full Text] [Related]
12. Non-invasive method to detect and locate haemorrhagic focus of GI tract. Shi J; Yan GZ; Wang KD; Fang Y J Med Eng Technol; 2007; 31(2):123-8. PubMed ID: 17365436 [TBL] [Abstract][Full Text] [Related]
13. Forehead pulse oximetry compared with finger pulse oximetry and arterial blood gas measurement. Cheng EY; Hopwood MB; Kay J J Clin Monit; 1988 Jul; 4(3):223-6. PubMed ID: 3210070 [TBL] [Abstract][Full Text] [Related]
14. VCSEL based, wearable, continuously monitoring pulse oximeter. Kollmann D; Hogan WK; Steidl C; Hibbs-Brenner MK; Hedin DS; Lichter PA Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():4156-9. PubMed ID: 24110647 [TBL] [Abstract][Full Text] [Related]
15. An in vivo investigation of photoplethysmographic signals and preliminary pulse oximetry estimation from the bowel using a new fiberoptic sensor. Hickey M; Samuels N; Randive N; Langford RM; Kyriacou PA Anesth Analg; 2011 May; 112(5):1104-9. PubMed ID: 21346164 [TBL] [Abstract][Full Text] [Related]
16. Selection of pulse oximetry equipment for ambulatory monitoring. Barratt CW; Vyas H; Hayes-Gill BR; Crowe JA J Med Eng Technol; 2001; 25(1):17-24. PubMed ID: 11345096 [TBL] [Abstract][Full Text] [Related]
17. Comparison of finger and forehead oximetry sensors in postanesthesia care patients. Blaylock V; Brinkman M; Carver S; McLain P; Matteson S; Newland P; Pettit R; Schulman C; vanSchijndel W; Watson S; J Perianesth Nurs; 2008 Dec; 23(6):379-86. PubMed ID: 19038744 [TBL] [Abstract][Full Text] [Related]
18. In-ear heart rate monitoring using a micro-optic reflective sensor. Vogel S; Hülsbusch M; Starke D; Leonhardt S Annu Int Conf IEEE Eng Med Biol Soc; 2007; 2007():1375-8. PubMed ID: 18002220 [TBL] [Abstract][Full Text] [Related]