These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

153 related articles for article (PubMed ID: 18002317)

  • 1. Health technology assessment on reprocessing single-use catheters for cardiac electrophysiology: results of a three-years study.
    Tessarolo F; Disertori M; Caola I; Guarrera GM; Favaretti C; Nollo G
    Annu Int Conf IEEE Eng Med Biol Soc; 2007; 2007():1758-61. PubMed ID: 18002317
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Sterility and microbiological assessment of reused single-use cardiac electrophysiology catheters.
    Tessarolo F; Caola I; Caciagli P; Guarrera GM; Nollo G
    Infect Control Hosp Epidemiol; 2006 Dec; 27(12):1385-92. PubMed ID: 17152039
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Functional properties and performance of new and reprocessed coronary angioplasty balloon catheters.
    Fedel M; Tessarolo F; Ferrari P; Lösche C; Ghassemieh N; Guarrera GM; Nollo G
    J Biomed Mater Res B Appl Biomater; 2006 Aug; 78(2):364-72. PubMed ID: 16506183
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Reprocessing and reuse of single-use medical devices used during hemodynamic procedures in Brazil: a widespread and largely overlooked problem.
    Amarante JM; Toscano CM; Pearson ML; Roth V; Jarvis WR; Levin AS
    Infect Control Hosp Epidemiol; 2008 Sep; 29(9):854-8. PubMed ID: 18647118
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Technical and economic feasibility of reusing disposable perfusion cannulae.
    Bloom DF; Cornhill JF; Malchesky PS; Richardson DM; Bolsen KA; Haire DM; Loop FD; Cosgrove DM
    Biomed Instrum Technol; 1997; 31(3):248-9. PubMed ID: 9181243
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Efficiency in endotoxin removal by a reprocessing protocol for electrophysiology catheters based on hydrogen peroxide plasma sterilization.
    Tessarolo F; Caola I; Nollo G; Antolini R; Guarrera GM; Caciagli P
    Int J Hyg Environ Health; 2006 Nov; 209(6):557-65. PubMed ID: 16793342
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of performance characteristics between new and reprocessed electrophysiology catheters.
    Lester BR; Alexander AA; Miller K; Boser NP; Sullivan BF; Brucker GG
    J Interv Card Electrophysiol; 2006 Nov; 17(2):77-83. PubMed ID: 17226083
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Safety evaluation of single-use medical devices after submission to simulated reutilization cycles.
    da Silva MV; Ribeiro Ade F; Pinto Tde J
    J AOAC Int; 2005; 88(3):823-9. PubMed ID: 16001858
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Single-use device reuse risks.
    Lee RC; Berzins S; Alfieri N
    Can J Infect Control; 2007; 22(3):142, 144, 146 passim. PubMed ID: 18044383
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Reprocessing of electrophysiology catheters: clinical studies, regulations, and recommendations. A report of the NASPE Task Force on Reprocessing of Electrophysiological Catheters. North American Society of Pacing and Electrophysiology.
    Lindsay BD; Kutalek SP; Cannom DS; Hammill SC; Naccarelli GV;
    Pacing Clin Electrophysiol; 2001 Aug; 24(8 Pt 1):1297-305. PubMed ID: 11523622
    [No Abstract]   [Full Text] [Related]  

  • 11. Plasma-based sterilization: effect on surface and bulk properties and hydrolytic stability of reprocessed polyurethane electrophysiology catheters.
    Lerouge S; Guignot C; Tabrizian M; Ferrier D; Yagoubi N; Yahia L
    J Biomed Mater Res; 2000 Dec; 52(4):774-82. PubMed ID: 11033561
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Reuse of Single-Use Devices in Endourology: A Review.
    Ghorai RP; Kumar R
    J Endourol; 2024 Jan; 38(1):68-76. PubMed ID: 37885229
    [No Abstract]   [Full Text] [Related]  

  • 13. [Reuse of "single use" medical devices after quality assured reprocessing: hygienic, legal and economic aspects. Potential for cost savings in interventional cardiology].
    Ischinger TA; Neubauer G; Ujlaky R; Schätzl H; Bock M
    Z Kardiol; 2002 Nov; 91(11):889-98. PubMed ID: 12442191
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Reprocessing of electrophysiology material in EHRA countries: an EHRA Young EP survey.
    Duncker D; Svetlosak M; Guerra F; Nagy KV; Vanduynhoven P; Mikhaylov EN; Kosiuk J
    Europace; 2021 Mar; 23(3):479-485. PubMed ID: 33083819
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Improving water quality can reduce pyrogenic reactions associated with reuse of cardiac catheters.
    Duffy RE; Couto B; Pessoa JM; Starling C; Pinheiro S; Pearson ML; Arduino MJ; Mattson BJ; Jarvis WR
    Infect Control Hosp Epidemiol; 2003 Dec; 24(12):955-60. PubMed ID: 14700413
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Safety issue of re-sterilization of polyurethane electrophysiology catheters: a cytotoxicity study.
    Ma N; Petit A; Huk OL; Yahia L; Tabrizian M
    J Biomater Sci Polym Ed; 2003; 14(3):213-26. PubMed ID: 12713095
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Reprocessing and sterilization of single-use electrophysiological catheters: removal of organic carbon and protein surface residues.
    Lester BR; Boser NP; Miller K; Schnapf M; Jacques BA; Sullivan BF; Marchin GL
    J AOAC Int; 2009; 92(4):1165-73. PubMed ID: 19714986
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Specific hygiene issues relating to reprocessing and reuse of single-use devices for laparoscopic surgery.
    Roth K; Heeg P; Reichl R
    Surg Endosc; 2002 Jul; 16(7):1091-7. PubMed ID: 12165829
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Reprocessing single-use devices--the ethical dilemma.
    Dunn D
    AORN J; 2002 May; 75(5):989-99; quiz 1000-4. PubMed ID: 12063946
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Conception and validation of a protocol for reuse of non-irrigated electrophysiology catheters in a Brazilian teaching hospital.
    Leichsenring ML; Psaltikidis EM; de Oliveira Figueiredo MJ; Moretti ML; Trabasso P
    J Interv Card Electrophysiol; 2018 Jan; 51(1):45-50. PubMed ID: 29230637
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.