These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
129 related articles for article (PubMed ID: 18005610)
1. [Nutrient artery entrance on the posterolateral wall of thoracic vertebral bodies: another potential landmark for vertebral screw insertion]. Qiu Y; Rui BY; Zhu ZZ; Zhu F Zhonghua Wai Ke Za Zhi; 2007 Aug; 45(16):1105-7. PubMed ID: 18005610 [TBL] [Abstract][Full Text] [Related]
2. [Thoracic scoliosis following anterior and posterior instrumentation and fusion]. Qiu Y; Wang WJ; Wang B; Zhu ZZ; Zhu F; Yu Y; Qian BP; Ma WW Zhonghua Wai Ke Za Zhi; 2007 Dec; 45(24):1708-13. PubMed ID: 18476532 [TBL] [Abstract][Full Text] [Related]
3. Anatomic considerations of anterior instrumentation of the thoracic spine. Ebraheim NA; Xu R; Ahmad M; Yeasting RA Am J Orthop (Belle Mead NJ); 1997 Jun; 26(6):419-24. PubMed ID: 9193696 [TBL] [Abstract][Full Text] [Related]
4. Location of the vertebral artery in the cervicothoracic junction. Xu R; Ebraheim NA; Tang G; Stanescu S Am J Orthop (Belle Mead NJ); 2000 Jun; 29(6):453-6. PubMed ID: 10890459 [TBL] [Abstract][Full Text] [Related]
5. Anterior vertebral body screw position placed thoracoscopically: a function of anatomy and surgeon experience in a porcine model. Zhang H; Sucato DJ; Welch RD Spine (Phila Pa 1976); 2004 Apr; 29(7):815-22. PubMed ID: 15087805 [TBL] [Abstract][Full Text] [Related]
6. The anatomical relationship between the aorta and the thoracic vertebral bodies and its importance in the placement of the screw in thoracoscopic correction of scoliosis. Qiu Y; He YX; Wang B; Zhu F; Wang WJ Eur Spine J; 2007 Sep; 16(9):1367-72. PubMed ID: 17410383 [TBL] [Abstract][Full Text] [Related]
7. [Treatment of thoracic vertebrae fracture with vertebral pedicle-screw placement in selected injured vertebrae]. Wang L; Tian JW; Dong SH; Zhao QH; Xia T Zhonghua Yi Xue Za Zhi; 2008 Aug; 88(31):2187-90. PubMed ID: 19080668 [TBL] [Abstract][Full Text] [Related]
8. Nutrient foramen location on the laminae provides a landmark for pedicle screw entry: a cadaveric study. Oshina M; Oshima Y; Matsubayashi Y; Taniguchi Y; Chikuda H; Riew KD; Tanaka S BMC Musculoskelet Disord; 2018 Aug; 19(1):293. PubMed ID: 30115052 [TBL] [Abstract][Full Text] [Related]
9. Anatomic Relationship of Bony Structures in Pedicle-Rib Unit and its Significance. Chen F; Liu X; Wang G; Sun J; Cui X World Neurosurg; 2020 Jul; 139():e691-e699. PubMed ID: 32339739 [TBL] [Abstract][Full Text] [Related]
10. Recording diffusion responses from contralateral intercostal muscles after stimulus-triggered electromyography: refining a tool for the assessment of thoracic pedicle screw placement in an experimental porcine model. de Blas G; Burgos J; Regidor I; Barrios C; Solá R; García-Urquiza S; Hevia E Spine (Phila Pa 1976); 2009 May; 34(11):E391-6. PubMed ID: 19444052 [TBL] [Abstract][Full Text] [Related]
11. The position of the aorta relative to the spine: is it mobile or not? Huitema GC; Cornips EM; Castelijns MH; van Ooij A; van Santbrink H; van Rhijn LW Spine (Phila Pa 1976); 2007 May; 32(12):1259-64. PubMed ID: 17515812 [TBL] [Abstract][Full Text] [Related]
12. Does the direction of pedicle screw rotation affect the biomechanics of direct transverse plane vertebral derotation? Parent S; Odell T; Oka R; Mahar A; Newton P Spine (Phila Pa 1976); 2008 Aug; 33(18):1966-9. PubMed ID: 18708929 [TBL] [Abstract][Full Text] [Related]
14. [Bony anatomical characteristics of posterolateral region of lumbar vertebrae and clinical significance thereof]. Lin HB; Zheng XH; Chen ZG; Dai JB Zhonghua Yi Xue Za Zhi; 2008 Apr; 88(15):1051-4. PubMed ID: 18754439 [TBL] [Abstract][Full Text] [Related]
15. Biomechanical effect of the extent of vertebral body fracture on the thoracolumbar spine with pedicle screw fixation: an in vitro study. Wang XY; Dai LY; Xu HZ; Chi YL J Clin Neurosci; 2008 Mar; 15(3):286-90. PubMed ID: 18226530 [TBL] [Abstract][Full Text] [Related]
16. [Clinical application of thoracic transverse process using as the position for thoracic pedicle screw implantation]. Xiao BP; Li M; Xu RM; Hu Y Zhongguo Gu Shang; 2009 Jun; 22(6):454-5. PubMed ID: 19594047 [TBL] [Abstract][Full Text] [Related]
17. [Finite element analysis of stress changes of posterior spinal pedicle screw infixation]. Yan JZ; Wu ZH; Xu RX; Wang XS; Xing ZJ; Zhao Y; Zhang JG; Shen JX; Wang YP; Qiu GX Zhonghua Yi Xue Za Zhi; 2009 Jan; 89(1):7-11. PubMed ID: 19489235 [TBL] [Abstract][Full Text] [Related]
18. Anatomic considerations of costotransverse screw placement in the thoracic spine. Xu R; Ebraheim NA; Ou Y; Skie M; Yeasting RA Surg Neurol; 2000 Apr; 53(4):349-54; discussion 354-5. PubMed ID: 10825520 [TBL] [Abstract][Full Text] [Related]
19. [A biomechanical study of stability of atlantoaxial junction fixation with anterior approach screw fixation through C2 vertebral body to C1 lateral mass and Gallie's technique]. Guo L; Quan Z; Ou Y Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2008 Jun; 22(6):707-10. PubMed ID: 18630569 [TBL] [Abstract][Full Text] [Related]
20. Digital Anatomical Measurement for Anterolateral Fixation of Middle and Lower Thoracic Vertebrae. Li X; En H; Zhang Y; Gao S; Li G; Guo Y; Wang X; Wang H; Cai Y; Wang Z; Li Z; Li C; Zhao F Med Sci Monit; 2016 Dec; 22():5021-5027. PubMed ID: 27997524 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]