BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

345 related articles for article (PubMed ID: 18022489)

  • 1. Comparative analysis of the threaded and tapered locking reconstruction plates.
    Coletti DP; Caccamese JF; Norby C; Edwards S; von Fraunhofer JA
    J Oral Maxillofac Surg; 2007 Dec; 65(12):2587-93. PubMed ID: 18022489
    [No Abstract]   [Full Text] [Related]  

  • 2. Effect of the number of screws on the stability of locking mandibular reconstruction plates.
    Pereira-Filho VA; da Silva BN; Nunes Reis JM; Spin-Neto R; Real Gabrielli MF; Monnazzi MS
    Int J Oral Maxillofac Surg; 2013 Jun; 42(6):732-5. PubMed ID: 23528747
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Treatment of mandibular angle fractures.
    Weber WD
    Atlas Oral Maxillofac Surg Clin North Am; 1997 Mar; 5(1):77-125. PubMed ID: 11905346
    [No Abstract]   [Full Text] [Related]  

  • 4. Current treatment of mandibular fractures--an overview.
    Beirne JC; Brady A; Dhaif G
    J Ir Dent Assoc; 1995; 41(2):30-1. PubMed ID: 8975062
    [No Abstract]   [Full Text] [Related]  

  • 5. Management of mandibular body fractures.
    Kushner GM; Alpert B
    Atlas Oral Maxillofac Surg Clin North Am; 1997 Mar; 5(1):61-76. PubMed ID: 11905345
    [No Abstract]   [Full Text] [Related]  

  • 6. Treatment of comminuted fractures of the mandible.
    Assael LA
    Atlas Oral Maxillofac Surg Clin North Am; 1997 Mar; 5(1):157-79. PubMed ID: 11905342
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Mandibular fracture reduction without intraoperative intermaxillary fixation: a technique using two modified reduction forceps.
    Shinohara EH; Mitsuda ST; Miyagusko JM; Horikawa FK
    J Contemp Dent Pract; 2006 Feb; 7(1):150-6. PubMed ID: 16491158
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Fixation of dicapitular fractures of the mandibular condyle with a headless bone screw.
    Loukota RA
    Br J Oral Maxillofac Surg; 2007 Jul; 45(5):399-401. PubMed ID: 16460849
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Infections associated with locking reconstruction plates: a retrospective review.
    Kirkpatrick D; Gandhi R; Van Sickels JE
    J Oral Maxillofac Surg; 2003 Apr; 61(4):462-6. PubMed ID: 12684964
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of locking and nonlocking plates in the treatment of mandibular condyle fractures.
    Seemann R; Frerich B; Müller S; Koenke R; Ploder O; Schicho K; Piffko J; Poeschl P; Wagner A; Wanschitz F; Krennmair G; Ewers R; Klug C
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2009 Sep; 108(3):328-34. PubMed ID: 19574070
    [No Abstract]   [Full Text] [Related]  

  • 11. Re: Wood GD, Inion biodegradable plates: the first century. Br J Oral Maxillofac Surg 2006;44:38-41.
    Whitley S; Jones H; Patel M
    Br J Oral Maxillofac Surg; 2007 Mar; 45(2):173. PubMed ID: 16603281
    [No Abstract]   [Full Text] [Related]  

  • 12. Computerized analysis of resorbable polymer plates and screws for the rigid fixation of mandibular angle fractures.
    Cox T; Kohn MW; Impelluso T
    J Oral Maxillofac Surg; 2003 Apr; 61(4):481-7; discussion 487-8. PubMed ID: 12684967
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparative evaluation of 2.0-mm locking plate system vs 2.0-mm nonlocking plate system for mandibular fracture: a prospective randomized study.
    Singh V; Kumar I; Bhagol A
    Int J Oral Maxillofac Surg; 2011 Apr; 40(4):372-7. PubMed ID: 21194892
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Transoral 2.0-mm locking miniplate fixation of mandibular fractures plus 1 week of maxillomandibular fixation: a prospective study.
    Chritah A; Lazow SK; Berger JR
    J Oral Maxillofac Surg; 2005 Dec; 63(12):1737-41. PubMed ID: 16297694
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Symphysis and parasymphysis fractures.
    Chotkowski GC
    Atlas Oral Maxillofac Surg Clin North Am; 1997 Mar; 5(1):27-59. PubMed ID: 11905344
    [No Abstract]   [Full Text] [Related]  

  • 16. Use of monocortical miniplates for the intraoral treatment of mandibular fractures.
    Chiodo TA; Milles M
    Atlas Oral Maxillofac Surg Clin North Am; 2009 Mar; 17(1):19-25. PubMed ID: 19237124
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Repair of mandibular fractures using the 2.0 mm system. A review.
    Klotch DW; Gal RL
    J Craniomaxillofac Trauma; 1995; 1(1):38-42. PubMed ID: 11951441
    [TBL] [Abstract][Full Text] [Related]  

  • 18. 'Double barrel' 2.0mm mini-plates to fix fractures of the neck of the mandibular condyle.
    Shinohara EH; Martini MZ
    Br J Oral Maxillofac Surg; 2006 Apr; 44(2):166. PubMed ID: 15964107
    [No Abstract]   [Full Text] [Related]  

  • 19. The use of resorbable hardware for fixation of pediatric mandible fracture. Case report.
    Poore MC; Penna KJ
    N Y State Dent J; 2008; 74(4):58-61. PubMed ID: 18788183
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Treatment of a mandibular fracture with biodegradable plate in an infant: report of a case.
    Senel FC; Tekin US; Imamoglu M
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2006 Apr; 101(4):448-50. PubMed ID: 16545707
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 18.