These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

138 related articles for article (PubMed ID: 18023399)

  • 1. Electrocatalytic oxidation and determination of deferasirox and deferiprone on a nickel oxyhydroxide-modified electrode.
    Hajjizadeh M; Jabbari A; Heli H; Moosavi-Movahedi AA; Shafiee A; Karimian K
    Anal Biochem; 2008 Feb; 373(2):337-48. PubMed ID: 18023399
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The effects of deferiprone and deferasirox on the structure and function of beta-thalassemia hemoglobin.
    Moosavi-Movahedi AA; Mousavy SJ; Divsalar A; Babaahmadi A; Karimian K; Shafiee A; Kamarie M; Poursasan N; Farzami B; Riazi GH; Hakimelahi GH; Tsai FY; Ahmad F; Amani M; Saboury AA
    J Biomol Struct Dyn; 2009 Dec; 27(3):319-39. PubMed ID: 19795915
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Synthesis of Flower-like Nickel Hydroxide Nanosheets and Application in Electrochemical Determination of Famotidine.
    Dehdari Vais R; Yadegari H; Heli H
    Iran J Pharm Res; 2020; 19(1):120-137. PubMed ID: 32922475
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Nickel oxide nanotubes-carbon microparticles/Nafion nanocomposite for the electrooxidation and sensitive detection of metformin.
    Sattarahmady N; Heli H; Faramarzi F
    Talanta; 2010 Sep; 82(4):1126-35. PubMed ID: 20801308
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effects of deferasirox and deferiprone on cellular iron load in the human hepatoma cell line HepaRG.
    Gaboriau F; Leray AM; Ropert M; Gouffier L; Cannie I; Troadec MB; Loréal O; Brissot P; Lescoat G
    Biometals; 2010 Apr; 23(2):231-45. PubMed ID: 19997770
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Determination of a new oral iron chelator, ICL670, and its iron complex in plasma by high-performance liquid chromatography and ultraviolet detection.
    Rouan MC; Marfil F; Mangoni P; Séchaud R; Humbert H; Maurer G
    J Chromatogr B Biomed Sci Appl; 2001 May; 755(1-2):203-13. PubMed ID: 11393706
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Copper nanoparticles-modified carbon paste transducer as a biosensor for determination of acetylcholine.
    Heli H; Hajjizadeh M; Jabbari A; Moosavi-Movahedi AA
    Biosens Bioelectron; 2009 Apr; 24(8):2328-33. PubMed ID: 19237275
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A flower-like nickel oxide nanostructure: synthesis and application for choline sensing.
    Sattarahmady N; Heli H; Dehdari Vais R
    Talanta; 2014 Feb; 119():207-13. PubMed ID: 24401406
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Cobalt hydroxide nanoparticles modified glassy carbon electrode as a biosensor for electrooxidation and determination of some amino acids.
    Hasanzadeh M; Karim-Nezhad G; Shadjou N; Hajjizadeh M; Khalilzadeh B; Saghatforoush L; Abnosi MH; Babaei A; Ershad S
    Anal Biochem; 2009 Jun; 389(2):130-7. PubMed ID: 19306837
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A novel voltammetric sensor for amoxicillin based on nickel-curcumin complex modified carbon paste electrode.
    Ojani R; Raoof JB; Zamani S
    Bioelectrochemistry; 2012 Jun; 85():44-9. PubMed ID: 22243788
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Selective electrooxidation of uric acid in presence of ascorbic acid at a room temperature ionic liquid/nickel hexacyanoferarrate nanoparticles composite electrode.
    Babu RS; Prabhu P; Narayanan SS
    Colloids Surf B Biointerfaces; 2011 Dec; 88(2):755-63. PubMed ID: 21893398
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Fenton chemistry and iron chelation under physiologically relevant conditions: Electrochemistry and kinetics.
    Merkofer M; Kissner R; Hider RC; Brunk UT; Koppenol WH
    Chem Res Toxicol; 2006 Oct; 19(10):1263-9. PubMed ID: 17040095
    [TBL] [Abstract][Full Text] [Related]  

  • 13. DNA/nickel oxide nanoparticles/osmium(III)-complex modified electrode toward selective oxidation of l-cysteine and simultaneous detection of l-cysteine and homocysteine.
    Sharifi E; Salimi A; Shams E
    Bioelectrochemistry; 2012 Aug; 86():9-21. PubMed ID: 22296821
    [TBL] [Abstract][Full Text] [Related]  

  • 14. An electrochemical acetylcholine sensor based on lichen-like nickel oxide nanostructure.
    Sattarahmady N; Heli H; Vais RD
    Biosens Bioelectron; 2013 Oct; 48():197-202. PubMed ID: 23685316
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Nickel(II)-baicalein complex modified multiwall carbon nanotube paste electrode and its electrocatalytic oxidation toward glycine.
    Zheng L; Song JF
    Anal Biochem; 2009 Aug; 391(1):56-63. PubMed ID: 19433054
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Electrochemistry of norepinephrine on carbon-coated nickel magnetic nanoparticles modified electrode and analytical applications.
    Bian C; Zeng Q; Xiong H; Zhang X; Wang S
    Bioelectrochemistry; 2010 Aug; 79(1):1-5. PubMed ID: 19846352
    [TBL] [Abstract][Full Text] [Related]  

  • 17. An electrocatalytic transducer for L-cysteine detection based on cobalt hexacyanoferrate nanoparticles with a core-shell structure.
    Sattarahmady N; Heli H
    Anal Biochem; 2011 Feb; 409(1):74-80. PubMed ID: 20869939
    [TBL] [Abstract][Full Text] [Related]  

  • 18. In vitro blood distribution and plasma protein binding of the iron chelator deferasirox (ICL670) and its iron complex Fe-[ICL670]2 for rat, marmoset, rabbit, mouse, dog, and human.
    Weiss HM; Fresneau M; Camenisch GP; Kretz O; Gross G
    Drug Metab Dispos; 2006 Jun; 34(6):971-5. PubMed ID: 16531476
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Antiproliferative and apoptotic effects in rat and human hepatoma cell cultures of the orally active iron chelator ICL670 compared to CP20: a possible relationship with polyamine metabolism.
    Lescoat G; Chantrel-Groussard K; Pasdeloup N; Nick H; Brissot P; Gaboriau F
    Cell Prolif; 2007 Oct; 40(5):755-67. PubMed ID: 17877614
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Mechanically immobilized nickel aquapentacyanoferrate modified electrode as an amperometric sensor for the determination of BHA.
    Kumar SS; Narayanan SS
    Talanta; 2008 Jun; 76(1):54-9. PubMed ID: 18585240
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.