144 related articles for article (PubMed ID: 18028567)
1. Breath sound distribution images of patients with pneumonia and pleural effusion.
Mor R; Kushnir I; Meyer JJ; Ekstein J; Ben-Dov I
Respir Care; 2007 Dec; 52(12):1753-60. PubMed ID: 18028567
[TBL] [Abstract][Full Text] [Related]
2. Dynamic visualization of lung sounds with a vibration response device: a case series.
Dellinger RP; Parrillo JE; Kushnir A; Rossi M; Kushnir I
Respiration; 2008; 75(1):60-72. PubMed ID: 17551264
[TBL] [Abstract][Full Text] [Related]
3. Distribution of breath sound images in patients with pneumothoraces compared to healthy subjects. Diagnostic yield of vibration response imaging technology.
Blanco M; Mor R; Fraticelli A; Breen DP; Dutau H
Respiration; 2009; 77(2):173-8. PubMed ID: 19052446
[TBL] [Abstract][Full Text] [Related]
4. Vibration response imaging in the detection of pleural effusions: a feasibility study.
Anantham D; Herth FJ; Majid A; Michaud G; Ernst A
Respiration; 2009; 77(2):166-72. PubMed ID: 18974633
[TBL] [Abstract][Full Text] [Related]
5. Automated lung sound analysis in patients with pneumonia.
Murphy RL; Vyshedskiy A; Power-Charnitsky VA; Bana DS; Marinelli PM; Wong-Tse A; Paciej R
Respir Care; 2004 Dec; 49(12):1490-7. PubMed ID: 15571639
[TBL] [Abstract][Full Text] [Related]
6. Accuracy of gray-scale coding in lung sound mapping.
Mehta AC; Gat M; Mann S; Madison JM
Comput Med Imaging Graph; 2010 Jul; 34(5):362-9. PubMed ID: 20171843
[TBL] [Abstract][Full Text] [Related]
7. Validation of automatic wheeze detection in patients with obstructed airways and in healthy subjects.
Guntupalli KK; Alapat PM; Bandi VD; Kushnir I
J Asthma; 2008 Dec; 45(10):903-7. PubMed ID: 19085580
[TBL] [Abstract][Full Text] [Related]
8. A visual stethoscope to detect the position of the tracheal tube.
Kato H; Suzuki A; Nakajima Y; Makino H; Sanjo Y; Nakai T; Shiraishi Y; Katoh T; Sato S
Anesth Analg; 2009 Dec; 109(6):1836-42. PubMed ID: 19923511
[TBL] [Abstract][Full Text] [Related]
9. Accuracy and reliability of physical signs in the diagnosis of pleural effusion.
Kalantri S; Joshi R; Lokhande T; Singh A; Morgan M; Colford JM; Pai M
Respir Med; 2007 Mar; 101(3):431-8. PubMed ID: 16965906
[TBL] [Abstract][Full Text] [Related]
10. Vibration response imaging as a new tool for interventional-bronchoscopy outcome assessment: a prospective pilot study.
Becker HD; Slawik M; Miyazawa T; Gat M
Respiration; 2009; 77(2):179-94. PubMed ID: 19065052
[TBL] [Abstract][Full Text] [Related]
11. Vibration response imaging technology in healthy subjects.
Yigla M; Gat M; Meyer JJ; Friedman PJ; Maher TM; Madison JM
AJR Am J Roentgenol; 2008 Sep; 191(3):845-52. PubMed ID: 18716118
[TBL] [Abstract][Full Text] [Related]
12. Evaluation of obstructive lung disease with vibration response imaging.
Guntupalli KK; Reddy RM; Loutfi RH; Alapat PM; Bandi VD; Hanania NA
J Asthma; 2008 Dec; 45(10):923-30. PubMed ID: 19085584
[TBL] [Abstract][Full Text] [Related]
13. Wheeze detection based on time-frequency analysis of breath sounds.
Taplidou SA; Hadjileontiadis LJ
Comput Biol Med; 2007 Aug; 37(8):1073-83. PubMed ID: 17113064
[TBL] [Abstract][Full Text] [Related]
14. Vibration response imaging: evaluation of rater agreement in healthy subjects and subjects with pneumonia.
Bartziokas K; Daenas C; Preau S; Zygoulis P; Triantaris A; Kerenidi T; Makris D; Gourgoulianis KI; Daniil Z
BMC Med Imaging; 2010 Mar; 10():6. PubMed ID: 20222975
[TBL] [Abstract][Full Text] [Related]
15. [Changes in sound transmissibility through the canine thorax due to the experimental pleural effusion].
Yonemaru M; Abe T; Kobayashi H; Kawashiro T; Yokoyama T
Nihon Kyobu Shikkan Gakkai Zasshi; 1991 Jul; 29(7):829-35. PubMed ID: 1920978
[TBL] [Abstract][Full Text] [Related]
16. Spectral analysis of breath sounds in normal newborn infants.
Pasterkamp H; Fenton R; Leahy F; Chernick V
Med Instrum; 1983; 17(5):355-7. PubMed ID: 6646023
[TBL] [Abstract][Full Text] [Related]
17. Wheeze detection in the pediatric intensive care unit: comparison among physician, nurses, respiratory therapists, and a computerized respiratory sound monitor.
Prodhan P; Dela Rosa RS; Shubina M; Haver KE; Matthews BD; Buck S; Kacmarek RM; Noviski NN
Respir Care; 2008 Oct; 53(10):1304-9. PubMed ID: 18811991
[TBL] [Abstract][Full Text] [Related]
18. Association of hypoalbuminemia with the presence and size of pleural effusion in children with pneumonia.
Prais D; Kuzmenko E; Amir J; Harel L
Pediatrics; 2008 Mar; 121(3):e533-8. PubMed ID: 18310174
[TBL] [Abstract][Full Text] [Related]
19. Expression of soluble triggering receptor expression on myeloid cells-1 in pleural effusion.
Huang LY; Shi HZ; Liang QL; Wu YB; Qin XJ; Chen YQ
Chin Med J (Engl); 2008 Sep; 121(17):1656-61. PubMed ID: 19024094
[TBL] [Abstract][Full Text] [Related]
20. Influence of observer preferences and auscultatory skill on the choice of terms to describe lung sounds: a survey of staff physicians, residents and medical students.
Bohadana A; Azulai H; Jarjoui A; Kalak G; Izbicki G
BMJ Open Respir Res; 2020 Mar; 7(1):. PubMed ID: 32220901
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]