236 related articles for article (PubMed ID: 18034415)
1. [Automatic system control and its application in dialysis].
Santoro A; Mancini E; Ferramosca E
G Ital Nefrol; 2007; 24 Suppl 40():s69-79. PubMed ID: 18034415
[TBL] [Abstract][Full Text] [Related]
2. Biofeedback-driven dialysis: where are we?
Santoro A; Ferramosca E; Mancini E
Contrib Nephrol; 2008; 161():199-209. PubMed ID: 18451678
[TBL] [Abstract][Full Text] [Related]
3. Biofeedback in dialysis.
Santoro A; Mambelli E; Canova C; Lopez A; Sestigiani E; Mancini E
J Nephrol; 2003; 16 Suppl 7():S48-56. PubMed ID: 14733301
[TBL] [Abstract][Full Text] [Related]
4. Biofeedback systems and adaptive control hemodialysis treatment.
Azar AT
Saudi J Kidney Dis Transpl; 2008 Nov; 19(6):895-903. PubMed ID: 18974573
[TBL] [Abstract][Full Text] [Related]
5. Haemodialysis with on-line monitoring equipment: tools or toys?
Locatelli F; Buoncristiani U; Canaud B; Köhler H; Petitclerc T; Zucchelli P
Nephrol Dial Transplant; 2005 Jan; 20(1):22-33. PubMed ID: 15632348
[TBL] [Abstract][Full Text] [Related]
6. Blood volume- and blood temperature-controlled hemodialysis in critically ill patients: a 6-month, case-matched, open-label study.
du Cheyron D; Lucidarme O; Terzi N; Charbonneau P
Blood Purif; 2010; 29(3):245-51. PubMed ID: 20016148
[TBL] [Abstract][Full Text] [Related]
7. Physiological monitoring and control in hemodialysis: state of the art and outlook.
Kraemer M
Expert Rev Med Devices; 2006 Sep; 3(5):617-34. PubMed ID: 17064247
[TBL] [Abstract][Full Text] [Related]
8. Use of online blood volume and blood temperature monitoring during haemodialysis in critically ill patients with acute kidney injury: a single-centre randomized controlled trial.
du Cheyron D; Terzi N; Seguin A; Valette X; Prevost F; Ramakers M; Daubin C; Charbonneau P; Parienti JJ
Nephrol Dial Transplant; 2013 Feb; 28(2):430-7. PubMed ID: 22535635
[TBL] [Abstract][Full Text] [Related]
9. Prevention of dialysis hypotension episodes using fuzzy logic control system.
Mancini E; Mambelli E; Irpinia M; Gabrielli D; Cascone C; Conte F; Meneghel G; Cavatorta F; Antonelli A; Villa G; Dal Canton A; Cagnoli L; Aucella F; Fiorini F; Gaggiotti E; Triolo G; Nuzzo V; Santoro A
Nephrol Dial Transplant; 2007 May; 22(5):1420-7. PubMed ID: 17299006
[TBL] [Abstract][Full Text] [Related]
10. Treatment time, chronic inflammation, and hemodynamic stability: the overlooked parameters in hemodialysis quantification.
Zsom L; Zsom M; Fulop T; Flessner MF
Semin Dial; 2008; 21(5):395-400. PubMed ID: 18945325
[TBL] [Abstract][Full Text] [Related]
11. 1alpha(OH)D3 One-alpha-hydroxy-cholecalciferol--an active vitamin D analog. Clinical studies on prophylaxis and treatment of secondary hyperparathyroidism in uremic patients on chronic dialysis.
Brandi L
Dan Med Bull; 2008 Nov; 55(4):186-210. PubMed ID: 19232159
[TBL] [Abstract][Full Text] [Related]
12. [How can we improve symptomatic hypotension in hemodialysis patients: cold dialysis vs isothermic dialysis].
Ramos R; Soto C; Mestres R; Jara J; Zequera H; Merello JI; Moreso F
Nefrologia; 2007; 27(6):737-41. PubMed ID: 18336104
[TBL] [Abstract][Full Text] [Related]
13. The role of technology in hemodialysis.
Ronco C; Ghezzi PM; La Greca G
J Nephrol; 1999; 12 Suppl 2():S68-81. PubMed ID: 10688405
[TBL] [Abstract][Full Text] [Related]
14. Identification and control for automated regulation of hemodynamic variables during hemodialysis.
Javed F; Savkin AV; Chan GS; Mackie JD; Lovell NH
IEEE Trans Biomed Eng; 2011 Jun; 58(6):1686-97. PubMed ID: 21296702
[TBL] [Abstract][Full Text] [Related]
15. Changes in right ventricular pressures between hemodialysis sessions recorded by an implantable hemodynamic monitor.
Kjellström B; Braunschweig F; Löfberg E; Fux T; Grandjean PA; Linde C
Am J Cardiol; 2009 Jan; 103(1):119-23. PubMed ID: 19101241
[TBL] [Abstract][Full Text] [Related]
16. Temperature and thermal balance monitoring and control in dialysis.
Lopot F; Sulková S; Fortová M; Nejedlý B
Hemodial Int; 2003 Apr; 7(2):177-83. PubMed ID: 19379359
[TBL] [Abstract][Full Text] [Related]
17. New blood volume monitoring method for hemodialysis: A-V pressure gradient measurement by synchronized one-point reading.
Oda M; Hokama S; Sugaya K; Hatano T; Ogawa Y
Artif Organs; 2004 Jul; 28(7):683-9. PubMed ID: 15209863
[TBL] [Abstract][Full Text] [Related]
18. Interactive hemodialysis control system for improved cardiovascular stability.
Klein E; Wathen RL
Med Instrum; 1986; 20(2):80-4. PubMed ID: 3702784
[No Abstract] [Full Text] [Related]
19. Online monitoring in continuous renal replacement therapies.
Ronco C; Brendolan A; Bellomo R
Kidney Int Suppl; 1999 Nov; (72):S8-14. PubMed ID: 10560797
[TBL] [Abstract][Full Text] [Related]
20. Improving the efficiency of short-term single-needle hemodialysis.
Rostoker G; Griuncelli M; Loridon C; Bourlet T; Welsch K; Benmaadi A
Ren Fail; 2009; 31(4):261-6. PubMed ID: 19462273
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]