These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
218 related articles for article (PubMed ID: 18036908)
1. Predicting early coronary artery bypass graft failure by intraoperative transit time flow measurement. Tokuda Y; Song MH; Ueda Y; Usui A; Akita T Ann Thorac Surg; 2007 Dec; 84(6):1928-33. PubMed ID: 18036908 [TBL] [Abstract][Full Text] [Related]
2. Predicting midterm coronary artery bypass graft failure by intraoperative transit time flow measurement. Tokuda Y; Song MH; Oshima H; Usui A; Ueda Y Ann Thorac Surg; 2008 Aug; 86(2):532-6. PubMed ID: 18640329 [TBL] [Abstract][Full Text] [Related]
3. Prediction of graft flow impairment by intraoperative transit time flow measurement in off-pump coronary artery bypass using arterial grafts. Kim KB; Kang CH; Lim C Ann Thorac Surg; 2005 Aug; 80(2):594-8. PubMed ID: 16039211 [TBL] [Abstract][Full Text] [Related]
5. Predictive value of intraoperative transit-time flow measurement for short-term graft patency in coronary surgery. Di Giammarco G; Pano M; Cirmeni S; Pelini P; Vitolla G; Di Mauro M J Thorac Cardiovasc Surg; 2006 Sep; 132(3):468-74. PubMed ID: 16935097 [TBL] [Abstract][Full Text] [Related]
6. Graft control by transit time flow measurement and intraoperative angiography in coronary artery bypass surgery. Hol PK; Fosse E; Mork BE; Lundblad R; Rein KA; Lingaas PS; Geiran O; Svennevig JL; Tonnessen TI; Nitter-Hauge S; Due-Tonnessen P; Vatne K; Smith HJ Heart Surg Forum; 2001; 4(3):254-7; discussion 257-8. PubMed ID: 11673148 [TBL] [Abstract][Full Text] [Related]
7. Transit-time flow measurement is essential in coronary artery bypass grafting. Leong DK; Ashok V; Nishkantha A; Shan YH; Sim EK Ann Thorac Surg; 2005 Mar; 79(3):854-7; discussion 857-8. PubMed ID: 15734393 [TBL] [Abstract][Full Text] [Related]
8. A randomized comparison of intraoperative indocyanine green angiography and transit-time flow measurement to detect technical errors in coronary bypass grafts. Desai ND; Miwa S; Kodama D; Koyama T; Cohen G; Pelletier MP; Cohen EA; Christakis GT; Goldman BS; Fremes SE J Thorac Cardiovasc Surg; 2006 Sep; 132(3):585-94. PubMed ID: 16935114 [TBL] [Abstract][Full Text] [Related]
9. Cut-off values for transit time flowmetry: are the revision criteria appropriate? Une D; Deb S; Chikazawa G; Kommaraju K; Tsuneyoshi H; Karkhanis R; Singh S; Vincent J; Tsubota H; Sever J; Moussa F; Cohen G; Christakis GT; Fremes SE J Card Surg; 2013 Jan; 28(1):3-7. PubMed ID: 23189982 [TBL] [Abstract][Full Text] [Related]
10. Effects of intra-aortic balloon pumping on graft flow in coronary surgery: an intraoperative transit-time flowmetric study. Takami Y; Masumoto H Ann Thorac Surg; 2008 Sep; 86(3):823-7. PubMed ID: 18721567 [TBL] [Abstract][Full Text] [Related]
11. Clinical value of intra-operative transit-time flow measurement for coronary artery bypass grafting: a prospective angiography-controlled study. Jokinen JJ; Werkkala K; Vainikka T; Peräkylä T; Simpanen J; Ihlberg L Eur J Cardiothorac Surg; 2011 Jun; 39(6):918-23. PubMed ID: 21095134 [TBL] [Abstract][Full Text] [Related]
12. The impact of intraoperative transit time flow measurement on the results of on-pump coronary surgery. Becit N; Erkut B; Ceviz M; Unlu Y; Colak A; Kocak H Eur J Cardiothorac Surg; 2007 Aug; 32(2):313-8. PubMed ID: 17555979 [TBL] [Abstract][Full Text] [Related]
13. Can transit-time flow measurement improve graft patency and clinical outcome in patients undergoing coronary artery bypass grafting? Di Giammarco G; Rabozzi R Interact Cardiovasc Thorac Surg; 2010 Nov; 11(5):635-40. PubMed ID: 20682631 [TBL] [Abstract][Full Text] [Related]
14. [The correlation between flow pattern during cardiopulmonary bypass and patency of the coronary artery bypass grafts]. Hagiwara H; Shirakawa M; Nakayama T; Asai T; Nakayama M; Ito T; Yano Y Kyobu Geka; 2005 Jul; 58(7):519-23; discussion 524-6. PubMed ID: 16004331 [TBL] [Abstract][Full Text] [Related]
15. Maximal blood flow acceleration analysis in the early diastolic phase for in situ internal thoracic artery bypass grafts: a new transit-time flow measurement predictor of graft failure following coronary artery bypass grafting. Handa T; Orihashi K; Nishimori H; Fukutomi T; Yamamoto M; Kondo N; Tashiro M Interact Cardiovasc Thorac Surg; 2015 Apr; 20(4):449-57. PubMed ID: 25574034 [TBL] [Abstract][Full Text] [Related]
16. Surgeon judgment and utility of transit time flow probes in coronary artery bypass grafting surgery. Quin J; Lucke J; Hattler B; Gupta S; Baltz J; Bishawi M; Almassi GH; Grover FL; Collins J; Shroyer AL JAMA Surg; 2014 Nov; 149(11):1182-7. PubMed ID: 25251332 [TBL] [Abstract][Full Text] [Related]
17. Predictors of early graft failure after coronary artery bypass grafting for chronic total occlusion. Oshima H; Tokuda Y; Araki Y; Ishii H; Murohara T; Ozaki Y; Usui A Interact Cardiovasc Thorac Surg; 2016 Jul; 23(1):142-9. PubMed ID: 27030683 [TBL] [Abstract][Full Text] [Related]
19. The accuracy of transit time flow measurement in predicting graft patency after coronary artery bypass grafting. Walker PF; Daniel WT; Moss E; Thourani VH; Kilgo P; Liberman HA; Devireddy C; Guyton RA; Puskas JD; Halkos ME Innovations (Phila); 2013; 8(6):416-9. PubMed ID: 24356431 [TBL] [Abstract][Full Text] [Related]
20. The predictive value of intraoperative transit-time flow measurement parameters for early graft failure in different target territories. Zhang G; Zhao Z; Han Z; Gao Q; Liu J; Chen Y J Cardiol; 2021 Feb; 77(2):201-205. PubMed ID: 33012590 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]