309 related articles for article (PubMed ID: 18042374)
1. Development of a temperature sensor array chip and a chip-based real-time PCR machine for DNA amplification efficiency-based quantification.
Lee DS; Chen CS
Biosens Bioelectron; 2008 Feb; 23(7):971-9. PubMed ID: 18042374
[TBL] [Abstract][Full Text] [Related]
2. Microchamber array based DNA quantification and specific sequence detection from a single copy via PCR in nanoliter volumes.
Matsubara Y; Kerman K; Kobayashi M; Yamamura S; Morita Y; Tamiya E
Biosens Bioelectron; 2005 Feb; 20(8):1482-90. PubMed ID: 15626601
[TBL] [Abstract][Full Text] [Related]
3. Real-time PCR in a plastic chip based on solid state FRET.
Sabella S; Vecchio G; Cingolani R; Rinaldi R; Pompa PP
Langmuir; 2008 Dec; 24(23):13266-9. PubMed ID: 18980361
[TBL] [Abstract][Full Text] [Related]
4. Clinical evaluation of micro-scale chip-based PCR system for rapid detection of hepatitis B virus.
Cho YK; Kim J; Lee Y; Kim YA; Namkoong K; Lim H; Oh KW; Kim S; Han J; Park C; Pak YE; Ki CS; Choi JR; Myeong HK; Ko C
Biosens Bioelectron; 2006 May; 21(11):2161-9. PubMed ID: 16290126
[TBL] [Abstract][Full Text] [Related]
5. Real-time electrochemical monitoring of the polymerase chain reaction by mediated redox catalysis.
Deféver T; Druet M; Rochelet-Dequaire M; Joannes M; Grossiord C; Limoges B; Marchal D
J Am Chem Soc; 2009 Aug; 131(32):11433-41. PubMed ID: 19722651
[TBL] [Abstract][Full Text] [Related]
6. Critical points of DNA quantification by real-time PCR--effects of DNA extraction method and sample matrix on quantification of genetically modified organisms.
Cankar K; Stebih D; Dreo T; Zel J; Gruden K
BMC Biotechnol; 2006 Aug; 6():37. PubMed ID: 16907967
[TBL] [Abstract][Full Text] [Related]
7. A rapid real-time qRT-PCR assay for ovine beta-actin mRNA.
Bjarnadottir H; Jonsson JJ
J Biotechnol; 2005 May; 117(2):173-82. PubMed ID: 15823406
[TBL] [Abstract][Full Text] [Related]
8. Real-time PCR microfluidic devices with concurrent electrochemical detection.
Fang TH; Ramalingam N; Xian-Dui D; Ngin TS; Xianting Z; Lai Kuan AT; Peng Huat EY; Hai-Qing G
Biosens Bioelectron; 2009 Mar; 24(7):2131-6. PubMed ID: 19162460
[TBL] [Abstract][Full Text] [Related]
9. A molecular beacon DNA microarray system for rapid detection of E. coli O157:H7 that eliminates the risk of a false negative signal.
Kim H; Kane MD; Kim S; Dominguez W; Applegate BM; Savikhin S
Biosens Bioelectron; 2007 Jan; 22(6):1041-7. PubMed ID: 16815005
[TBL] [Abstract][Full Text] [Related]
10. A micro circulating PCR chip using a suction-type membrane for fluidic transport.
Chien LJ; Wang JH; Hsieh TM; Chen PH; Chen PJ; Lee DS; Luo CH; Lee GB
Biomed Microdevices; 2009 Apr; 11(2):359-67. PubMed ID: 18975094
[TBL] [Abstract][Full Text] [Related]
11. Liquid-based hybridization assay with real-time detection in miniaturized array platforms.
Guerasimova A; Nyarsik L; Liu JP; Schwartz R; Lange M; Lehrach H; Janitz M
Biomol Eng; 2006 Mar; 23(1):35-40. PubMed ID: 16298548
[TBL] [Abstract][Full Text] [Related]
12. Ultrasensitive DNA chip: gene expression profile analysis without RNA amplification.
Nagino K; Nomura O; Takii Y; Myomoto A; Ichikawa M; Nakamura F; Higasa M; Akiyama H; Nobumasa H; Shiojima S; Tsujimoto G
J Biochem; 2006 Apr; 139(4):697-703. PubMed ID: 16672270
[TBL] [Abstract][Full Text] [Related]
13. The real-time polymerase chain reaction.
Kubista M; Andrade JM; Bengtsson M; Forootan A; Jonák J; Lind K; Sindelka R; Sjöback R; Sjögreen B; Strömbom L; Ståhlberg A; Zoric N
Mol Aspects Med; 2006; 27(2-3):95-125. PubMed ID: 16460794
[TBL] [Abstract][Full Text] [Related]
14. A standard curve based method for relative real time PCR data processing.
Larionov A; Krause A; Miller W
BMC Bioinformatics; 2005 Mar; 6():62. PubMed ID: 15780134
[TBL] [Abstract][Full Text] [Related]
15. Real-time monitoring of the strand displacement amplification (SDA) of human cytomegalovirus by a new SDA-piezoelectric DNA sensor system.
Chen Q; Bian Z; Chen M; Hua X; Yao C; Xia H; Kuang H; Zhang X; Huang J; Cai G; Fu W
Biosens Bioelectron; 2009 Aug; 24(12):3412-8. PubMed ID: 19576755
[TBL] [Abstract][Full Text] [Related]
16. QDs-DNA nanosensor for the detection of hepatitis B virus DNA and the single-base mutants.
Wang X; Lou X; Wang Y; Guo Q; Fang Z; Zhong X; Mao H; Jin Q; Wu L; Zhao H; Zhao J
Biosens Bioelectron; 2010 Apr; 25(8):1934-40. PubMed ID: 20138498
[TBL] [Abstract][Full Text] [Related]
17. Direct and rapid electrochemical biosensing of the human interleukin-2 DNA in unpurified polymerase chain reaction (PCR)-amplified real samples.
Pournaghi-Azar MH; Alipour E; Zununi S; Froohandeh H; Hejazi MS
Biosens Bioelectron; 2008 Dec; 24(4):524-30. PubMed ID: 18617384
[TBL] [Abstract][Full Text] [Related]
18. Novel fluorescence detection technique for non-contact temperature sensing in microchip PCR.
Mondal S; Venkataraman V
J Biochem Biophys Methods; 2007 Aug; 70(5):773-7. PubMed ID: 17570532
[TBL] [Abstract][Full Text] [Related]
19. Homogeneous and one-step fluorescent allele-specific PCR for SNP genotyping assays using conjugated polyelectrolytes.
Duan X; Liu L; Wang S
Biosens Bioelectron; 2009 Mar; 24(7):2095-9. PubMed ID: 19070477
[TBL] [Abstract][Full Text] [Related]
20. A novel fluorescence-based array biosensor: principle and application to DNA hybridization assays.
Schultz E; Galland R; Du Bouëtiez D; Flahaut T; Planat-Chrétien A; Lesbre F; Hoang A; Volland H; Perraut F
Biosens Bioelectron; 2008 Feb; 23(7):987-94. PubMed ID: 18207730
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]