BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

215 related articles for article (PubMed ID: 18045043)

  • 1. [Adverse reactions to polysulphone membrane dialyzers durind hemodialysis].
    Arenas MD; Gil MT; Carretón MA; Moledous A; Albiach B
    Nefrologia; 2007; 27(5):638-42. PubMed ID: 18045043
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Anaphylactic reaction induced by a polysulfone/polyvinylpyrrolidone membrane in the 10th session of hemodialysis with the same dialyzer.
    Bacelar Marques ID; Pinheiro KF; de Freitas do Carmo LP; Costa MC; Abensur H
    Hemodial Int; 2011 Jul; 15(3):399-403. PubMed ID: 21624039
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Anaphylactic Shock at the Beginning of Hemodialysis.
    Sayeed K; Murdakes C; Spec A; Gashti C
    Semin Dial; 2016; 29(1):81-4. PubMed ID: 26538311
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Acute adverse effects of dialysis].
    Opatrný K
    Vnitr Lek; 2003 Feb; 49(2):134-42. PubMed ID: 12733493
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Incidence of Hypersensitivity Reactions During Hemodialysis.
    Esteras R; Martín-Navarro J; Ledesma G; Fernández-Prado R; Carreño G; Cintra M; Cidraque I; Sanz I; Tarragón B; Alexandru S; Milla M; Astudillo E; Sánchez E; Mas S; Tejeiro RD; Ortiz A; Sánchez R; González-Parra E
    Kidney Blood Press Res; 2018; 43(5):1472-1478. PubMed ID: 30235456
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Severe hypersensitivity reaction during hemodialysis.
    Kraske GK; Shinaberger JH; Klaustermeyer WB
    Ann Allergy Asthma Immunol; 1997 Feb; 78(2):217-20. PubMed ID: 9048531
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Dialyzer reactions in a patient switching from peritoneal dialysis to hemodialysis.
    Yang RC; Lindsay RM
    Hemodial Int; 2005 Apr; 9(2):120-6. PubMed ID: 16191059
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The past, present and future of the dialyzer.
    Mineshima M
    Contrib Nephrol; 2015; 185():8-14. PubMed ID: 26023010
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Thrombocytopenia associated with one type of polysulfone hemodialysis membrane: a report of 5 cases.
    De Prada L; Lee J; Gillespie A; Benjamin J
    Am J Kidney Dis; 2013 Jan; 61(1):131-3. PubMed ID: 23083811
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Hypersensitivity reactions to synthetic haemodialysis membranes.
    Sánchez-Villanueva RJ; González E; Quirce S; Díaz R; Alvarez L; Menéndez D; Rodríguez-Gayo L; Bajo MA; Selgas R
    Nefrologia; 2014; 34(4):520-5. PubMed ID: 25036066
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Does an alteration of dialyzer design and geometry affect biocompatibility parameters?
    Opatrný K; Krouzzecký A; Polanská K; Mares J; Tomsů M; Bowry SK; Vienken J
    Hemodial Int; 2006 Apr; 10(2):201-8. PubMed ID: 16623675
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Delayed near-fatal anaphylactic reaction induced by the F10-HPS polysulphone haemodialyser.
    Huang WH; Lee YY; Shih LC
    Nephrol Dial Transplant; 2008 Jan; 23(1):423-4. PubMed ID: 17893104
    [No Abstract]   [Full Text] [Related]  

  • 13. Hypersensitivity reactions to ethylene oxide: clinical experience.
    Masin G; Polenaković M; Ivanovski N; Atanasov N; Olivera S; Cakalaroski K
    Nephrol Dial Transplant; 1991; 6 Suppl 3():50-2. PubMed ID: 1775268
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A case of anaphylactoid shock induced by the BS polysulfone hemodialyzer but not by the F8-HPS polysulfone hemodialyzer.
    Ohashi N; Yonemura K; Goto T; Suzuki H; Fujigaki Y; Yamamoto T; Hishida A
    Clin Nephrol; 2003 Sep; 60(3):214-7. PubMed ID: 14524587
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Plasma bradykinin levels during hemodialysis with PAN DX and polysulfone membranes with and without concurrent ACE inhibitor.
    Wakasa M; Akizawa T; Kinugasa E; Koshikawa S
    Clin Nephrol; 1995 Nov; 44 Suppl 1():S29-32. PubMed ID: 8608658
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Thrombocytopenia associated with use of a biocompatible hemodialysis membrane: a case report.
    Post JB
    Am J Kidney Dis; 2010 Jun; 55(6):e25-8. PubMed ID: 20110145
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Mechanisms Involved in Hypersensitivity Reactions to Polysulfone Hemodialysis Membranes.
    Rodríguez-Sanz A; Sánchez-Villanueva R; Domínguez-Ortega J; Fiandor AM; Ruiz MP; Trocoli F; Díaz-Tejeiro R; Cadenillas C; González E; Martínez V; López-Trascasa M; Quirce S; Selgas R; Bellón T
    Artif Organs; 2017 Nov; 41(11):E285-E295. PubMed ID: 28722144
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Development of generalized bullous lesions after hemodialysis with polysulfone membrane dialyzer.
    Suo H; Su H; Lu C; Yang L; Tao J
    J Dermatol; 2020 Apr; 47(4):e119-e120. PubMed ID: 32067253
    [No Abstract]   [Full Text] [Related]  

  • 19. Dialyzer reuse--part II: advantages and disadvantages.
    Twardowski ZJ
    Semin Dial; 2006; 19(3):217-26. PubMed ID: 16689973
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Influence of polysulphone-derived dialysis membranes on the interaction of circulating mononuclear cells with the endothelium.
    Martínez-Miguel P; de Sequera P; Molina Á; Oviedo V; Grande J; Escaja C; Díaz H; Abreu E; Asensio M; Rodríguez-Puyol D; López-Ongil S
    Int J Artif Organs; 2014 Jun; 37(6):455-65. PubMed ID: 24811306
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.