204 related articles for article (PubMed ID: 18048898)
1. The design, use, and results of transcutaneous carbon dioxide analysis: current and future directions.
Eberhard P
Anesth Analg; 2007 Dec; 105(6 Suppl):S48-S52. PubMed ID: 18048898
[TBL] [Abstract][Full Text] [Related]
2. Validation of a new combined transcutaneous tcPCO
van Wijk JJ; van Weteringen W; Hoeks SE; Staals LM
Paediatr Anaesth; 2022 Mar; 32(3):429-435. PubMed ID: 34882905
[TBL] [Abstract][Full Text] [Related]
3. Transcutaneous PCO2 to monitor noninvasive mechanical ventilation in adults: assessment of a new transcutaneous PCO2 device.
Janssens JP; Howarth-Frey C; Chevrolet JC; Abajo B; Rochat T
Chest; 1998 Mar; 113(3):768-73. PubMed ID: 9515855
[TBL] [Abstract][Full Text] [Related]
4. Transcutaneous PCO2 monitoring in critically ill adults: clinical evaluation of a new sensor.
Bendjelid K; Schütz N; Stotz M; Gerard I; Suter PM; Romand JA
Crit Care Med; 2005 Oct; 33(10):2203-6. PubMed ID: 16215371
[TBL] [Abstract][Full Text] [Related]
5. Transcutaneous Carbon Dioxide Monitoring with Reduced-Temperature Probes in Very Low Birth Weight Infants.
Aly S; El-Dib M; Mohamed M; Aly H
Am J Perinatol; 2017 Apr; 34(5):480-485. PubMed ID: 27673754
[No Abstract] [Full Text] [Related]
6. Transcutaneous monitors during one-lung ventilation: are they reliable?
Chung MR; Lichtor JL; Rangachari K; Roizen MF
J Cardiothorac Anesth; 1988 Jun; 2(3):313-9. PubMed ID: 17171866
[TBL] [Abstract][Full Text] [Related]
7. Is continuous transcutaneous monitoring of PCO2 (TcPCO2) over 8 h reliable in adults?
Janssens JP; Perrin E; Bennani I; de Muralt B; Titelion V; Picaud C
Respir Med; 2001 May; 95(5):331-5. PubMed ID: 11392572
[TBL] [Abstract][Full Text] [Related]
8. Novel transcutaneous sensor combining optical tcPO
van Weteringen W; Goos TG; van Essen T; Ellenberger C; Hayoz J; de Jonge RCJ; Reiss IKM; Schumacher PM
Med Biol Eng Comput; 2020 Feb; 58(2):239-247. PubMed ID: 31741291
[TBL] [Abstract][Full Text] [Related]
9. Transcutaneous devices for the measurements of pO2 and pCO2. State-of-the-art, especially emphasizing a pCO2 sensor based on a solid-state glass pH sensor.
Larsen J; Linnet N; Vesterager P
Ann Biol Clin (Paris); 1993; 51(10-11):899-902. PubMed ID: 8210067
[TBL] [Abstract][Full Text] [Related]
10. Comparison of transcutaneous oxygen and carbon dioxide monitors in normal adults and critically ill patients.
Rithalia SV; Farrow P; Doran BR
Intensive Crit Care Nurs; 1992 Mar; 8(1):40-6. PubMed ID: 1559023
[TBL] [Abstract][Full Text] [Related]
11. Transcutaneous PCO2 monitors are more accurate than end-tidal PCO2 monitors.
Hirabayashi M; Fujiwara C; Ohtani N; Kagawa S; Kamide M
J Anesth; 2009; 23(2):198-202. PubMed ID: 19444557
[TBL] [Abstract][Full Text] [Related]
12. Transcutaneous carbon dioxide and oxygen tension measured at different temperatures in healthy adults.
Wimberley PD; Grønlund Pedersen K; Olsson J; Siggaard-Andersen O
Clin Chem; 1985 Oct; 31(10):1611-5. PubMed ID: 3930089
[TBL] [Abstract][Full Text] [Related]
13. tcPCO2 electrode design, calibration and temperature gradient problems.
Severinghaus JW; Stafford M; Bradley AF
Acta Anaesthesiol Scand Suppl; 1978; 68():118-22. PubMed ID: 29431
[TBL] [Abstract][Full Text] [Related]
14. Validity of transcutaneous PCO2 in monitoring chronic hypoventilation treated with non-invasive ventilation.
Aarrestad S; Tollefsen E; Kleiven AL; Qvarfort M; Janssens JP; Skjønsberg OH
Respir Med; 2016 Mar; 112():112-8. PubMed ID: 26874895
[TBL] [Abstract][Full Text] [Related]
15. Use of transcutaneous oxygen and carbon dioxide tensions for assessing indices of gas exchange during exercise testing.
Carter R; Banham SW
Respir Med; 2000 Apr; 94(4):350-5. PubMed ID: 10845433
[TBL] [Abstract][Full Text] [Related]
16. Evaluation of a new combined transcutaneous measurement of PCO2/pulse oximetry oxygen saturation ear sensor in newborn patients.
Bernet-Buettiker V; Ugarte MJ; Frey B; Hug MI; Baenziger O; Weiss M
Pediatrics; 2005 Jan; 115(1):e64-8. PubMed ID: 15601814
[TBL] [Abstract][Full Text] [Related]
17. Multisite evaluation of a continuous intraarterial blood gas monitoring system.
Larson CP; Vender J; Seiver A
Anesthesiology; 1994 Sep; 81(3):543-52. PubMed ID: 8092498
[TBL] [Abstract][Full Text] [Related]
18. Effects of the transcutaneous electrode temperature on the accuracy of transcutaneous carbon dioxide tension.
Sørensen LC; Brage-Andersen L; Greisen G
Scand J Clin Lab Invest; 2011 Nov; 71(7):548-52. PubMed ID: 21732731
[TBL] [Abstract][Full Text] [Related]
19. Clinical investigation of a new combined pulse oximetry and carbon dioxide tension sensor in adult anaesthesia.
Rohling R; Biro P
J Clin Monit Comput; 1999 Jan; 15(1):23-7. PubMed ID: 12578058
[TBL] [Abstract][Full Text] [Related]
20. Reliability of transcutaneous measurement of oxygen and carbon dioxide partial pressure with a combined Po2-Pco2 electrochemical sensor in the fetus during labor.
Schmidt S; Langner K; Dudenhausen JW; Saling E
J Perinat Med; 1985; 13(3):127-33. PubMed ID: 3928868
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]