These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

103 related articles for article (PubMed ID: 18050348)

  • 1. Optimization of scan parameters in pulmonary partial pressure oxygen measurement by hyperpolarized 3He MRI.
    Yu J; Ishii M; Law M; Woodburn JM; Emami K; Kadlecek S; Vahdat V; Guyer RA; Rizi RR
    Magn Reson Med; 2008 Jan; 59(1):124-31. PubMed ID: 18050348
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Measurement of pulmonary partial pressure of oxygen and oxygen depletion rate with hyperpolarized helium-3 MRI: a preliminary reproducibility study on pig model.
    Yu J; Rajaei S; Ishii M; Law M; Emami K; Woodburn JM; Kadlecek S; Vahdat V; Rizi RR
    Acad Radiol; 2008 Jun; 15(6):702-12. PubMed ID: 18486007
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Single-acquisition sequence for the measurement of oxygen partial pressure by hyperpolarized gas MRI.
    Fischer MC; Spector ZZ; Ishii M; Yu J; Emami K; Itkin M; Rizi R
    Magn Reson Med; 2004 Oct; 52(4):766-73. PubMed ID: 15389934
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Measurements of regional alveolar oxygen pressure using hyperpolarized 3He MRI.
    Fischer MC; Kadlecek S; Yu J; Ishii M; Emami K; Vahdat V; Lipson DA; Rizi RR
    Acad Radiol; 2005 Nov; 12(11):1430-9. PubMed ID: 16253855
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Quantification of regional intrapulmonary oxygen partial pressure evolution during apnea by (3)He MRI.
    Deninger AJ; Eberle B; Ebert M; Grossmann T; Heil W; Kauczor H; Lauer L; Markstaller K; Otten E; Schmiedeskamp J; Schreiber W; Surkau R; Thelen M; Weiler N
    J Magn Reson; 1999 Dec; 141(2):207-16. PubMed ID: 10579944
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Multiple regression method for pulmonary apparent diffusion coefficient measurement by hyperpolarized 3He MRI.
    Yu J; Ishii M; Kadlecek S; Lipson DA; Emami K; Clark TW; Rajaei S; Rizi RR
    J Magn Reson Imaging; 2007 May; 25(5):982-91. PubMed ID: 17457799
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Parallel imaging of hyperpolarized helium-3 with simultaneous slice excitation.
    Teh K; Lee KJ; Paley MN; Wild JM
    Magn Reson Med; 2006 Feb; 55(2):258-62. PubMed ID: 16408264
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Simultaneous measurement of pulmonary partial pressure of oxygen and apparent diffusion coefficient by hyperpolarized 3He MRI.
    Yu J; Law M; Kadlecek S; Emami K; Ishii M; Stephen M; Woodburn JM; Vahdat V; Rizi RR
    Magn Reson Med; 2009 May; 61(5):1015-21. PubMed ID: 19230017
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Free breathing hyperpolarized 3He lung ventilation spiral MR imaging.
    Bannier E; Neyran B; Cieslar K; Rivoire J; Heidemann RM; Gaillard S; Sulaiman AR; Canet-Soulas E; Cremillieux Y
    Invest Radiol; 2009 Apr; 44(4):185-91. PubMed ID: 19252441
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Alveolar oxygen partial pressure and oxygen depletion rate mapping in rats using 3He ventilation imaging.
    Cieślar K; Stupar V; Canet-Soulas E; Gaillard S; Crémillieux Y
    Magn Reson Med; 2007 Feb; 57(2):423-30. PubMed ID: 17152086
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Measurement of alveolar oxygen partial pressure in the rat lung using Carr-Purcell-Meiboom-Gill spin-spin relaxation times of hyperpolarized 3He and 129Xe at 74 mT.
    Kraayvanger RJ; Bidinosti CP; Dominguez-Viqueira W; Parra-Robles J; Fox M; Lam WW; Santyr GE
    Magn Reson Med; 2010 Nov; 64(5):1484-90. PubMed ID: 20593371
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Hyperpolarized 3He lung ventilation imaging with B1-inhomogeneity correction in a single breath-hold scan.
    Miller GW; Altes TA; Brookeman JR; De Lange EE; Mugler JP
    MAGMA; 2004 Apr; 16(5):218-26. PubMed ID: 15108030
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Measurement of nonlinear pO2 decay in mouse lungs using 3He-MRI.
    Cieślar K; Alsaid H; Stupar V; Gaillard S; Canet-Soulas E; Fissoune R; Crémillieux Y
    NMR Biomed; 2007 May; 20(3):383-91. PubMed ID: 17451167
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Flip-angle measurement by magnetization inversion: Calibration of magnetization nutation angle in hyperpolarized (3) He magnetic resonance imaging lung experiments.
    Rivoire J; Terekhov M; Meise FM; Gast K; Salhi Z; Schreiber LM
    Magn Reson Med; 2011 Feb; 65(2):399-408. PubMed ID: 20882641
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Ultrafast MRI of lung ventilation using hyperpolarized helium-3].
    Schreiber WG; Weiler N; Kauczor HU; Markstaller K; Eberle B; Hast J; Surkau R; Grossmann T; Deninger A; Hanisch G; Otten EW; Thelen M
    Rofo; 2000 Feb; 172(2):129-33. PubMed ID: 10723485
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [A software program for quantitative analysis of alveolar oxygen partial pressure (p(A)O(2)) with oxygen-sensitive (3)He-MRI].
    Lehmann F; Eberle B; Markstaller K; Gast KK; Schmiedeskamp J; Blümler P; Kauczor HU; Schreiber WG
    Rofo; 2004 Oct; 176(10):1390-8. PubMed ID: 15383969
    [TBL] [Abstract][Full Text] [Related]  

  • 17. K-space filter deconvolution and flip angle self-calibration in 2D radial hyperpolarised 3He lung MRI.
    Marshall H; Ajraoui S; Deppe MH; Parra-Robles J; Wild JM
    NMR Biomed; 2012 Feb; 25(2):389-99. PubMed ID: 21837646
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of oxygen sensitivity of hyperpolarized helium imaging for the detection of pulmonary ischemia.
    Walvick RP; Roche JP; Reno AL; Gounis MJ; Albert MS
    Magn Reson Med; 2016 May; 75(5):2050-4. PubMed ID: 26079271
    [TBL] [Abstract][Full Text] [Related]  

  • 19. MR imaging of mouse lung using hyperpolarized 3He: image acquisition and T1 estimation under spontaneous respiration.
    Imai H; Narazaki M; Inoshita H; Kimura A; Fujiwara H
    Magn Reson Med Sci; 2006 Jul; 5(2):57-64. PubMed ID: 17008761
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Regional alveolar partial pressure of oxygen measurement with parallel accelerated hyperpolarized gas MRI.
    Kadlecek S; Hamedani H; Xu Y; Emami K; Xin Y; Ishii M; Rizi R
    Acad Radiol; 2013 Oct; 20(10):1224-33. PubMed ID: 24029054
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.