These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

205 related articles for article (PubMed ID: 18051007)

  • 1. Evaluation of curing light distance on resin composite microhardness and polymerization.
    Rode KM; Kawano Y; Turbino ML
    Oper Dent; 2007; 32(6):571-8. PubMed ID: 18051007
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of composite curing parameters: effects of light source and curing mode on conversion, temperature rise and polymerization shrinkage.
    Tarle Z; Knezevic A; Demoli N; Meniga A; Sutaloa J; Unterbrink G; Ristic M; Pichler G
    Oper Dent; 2006; 31(2):219-26. PubMed ID: 16827025
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Early surface microhardness of a resin composite exposed to a pulse-delayed curing exposure: a comparison of a tungsten halogen and a plasma arc lamp, in vitro.
    Ray NJ; Lynch CD; Burke FM; Hannigan A
    Eur J Prosthodont Restor Dent; 2005 Dec; 13(4):177-81. PubMed ID: 16411575
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Microhardness of resin composites polymerized by plasma arc or conventional visible light curing.
    Park SH; Krejci I; Lutz F
    Oper Dent; 2002; 27(1):30-7. PubMed ID: 11817467
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Curing units' ability to cure restorative composites and dual-cured composite cements under composite overlay.
    Park SH; Kim SS; Cho YS; Lee CK; Noh BD
    Oper Dent; 2004; 29(6):627-35. PubMed ID: 15646217
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Composite depth of cure obtained with QTH and LED units assessed by microhardness and micro-Raman spectroscopy.
    Santos GB; Medeiros IS; Fellows CE; Muench A; Braga RR
    Oper Dent; 2007; 32(1):79-83. PubMed ID: 17288333
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Knoop microhardness and FT-Raman spectroscopic evaluation of a resin-based dental material light-cured by an argon ion laser and halogen lamp: an in vitro study.
    Cassoni A; Ferla Jde O; Shibli JA; Kawano Y
    Photomed Laser Surg; 2008 Dec; 26(6):531-9. PubMed ID: 19099385
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Curing efficiency of three different curing lights at different distances for a hybrid composite.
    Zhu S; Platt JA
    Am J Dent; 2009 Dec; 22(6):381-6. PubMed ID: 20178217
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Hardness and degree of conversion of posterior packable composites.
    Knobloch L; Kerby RE; Clelland N; Lee J
    Oper Dent; 2004; 29(6):642-9. PubMed ID: 15646219
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The effectiveness of cure of LED and halogen curing lights at varying cavity depths.
    Soh MS; Yap AU; Siow KS
    Oper Dent; 2003; 28(6):707-15. PubMed ID: 14653284
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Composite resin microhardness: the influence of light curing method, composite shade, and depth of cure.
    de Araújo CS; Schein MT; Zanchi CH; Rodrigues SA; Demarco FF
    J Contemp Dent Pract; 2008 May; 9(4):43-50. PubMed ID: 18473026
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Power distribution across the face of different light guides and its effect on composite surface microhardness.
    Vandewalle KS; Roberts HW; Rueggeberg FA
    J Esthet Restor Dent; 2008; 20(2):108-17; discussion 118. PubMed ID: 18380841
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Mechanical properties of light-cured composites polymerized with several additional post-curing methods.
    Soares CJ; Pizi EC; Fonseca RB; Martins LR
    Oper Dent; 2005; 30(3):389-94. PubMed ID: 15986961
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effect of a LED versus halogen light cure polymerization on the curing characteristics of three composite resins.
    Besnault C; Pradelle-Plasse N; Picard B; Colon P
    Am J Dent; 2003 Oct; 16(5):323-8. PubMed ID: 14677611
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Resin polymerization problems--are they caused by resin curing lights, resin formulations, or both?
    Christensen RP; Palmer TM; Ploeger BJ; Yost MP
    Compend Contin Educ Dent Suppl; 1999; (25):S42-54; quiz S74. PubMed ID: 11908396
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The linear shrinkage and microhardness of packable composites polymerized by QTH or PAC unit.
    Park SH; Noh BD; Cho YS; Kim SS
    Oper Dent; 2006; 31(1):3-10. PubMed ID: 16536187
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Polymerization depths of contemporary light-curing units using microhardness.
    Rueggeberg FA; Ergle JW; Mettenburg DJ
    J Esthet Dent; 2000; 12(6):340-9. PubMed ID: 14743529
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effect of light-tip distance on the shear bond strengths of composite resin.
    Cacciafesta V; Sfondrini MF; Scribante A; Boehme A; Jost-Brinkmann PG
    Angle Orthod; 2005 May; 75(3):386-91. PubMed ID: 15898377
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Microhardness of different thicknesses of resin composite polymerized by conventional photocuring at different distances.
    Aguirar FH; e Oliveria TR; Lima DA; Ambrosano Gm; Lovadino JR
    Gen Dent; 2008; 56(2):144-8. PubMed ID: 18348370
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effect of reduced exposure times on the microhardness of 10 resin composites cured by high-power LED and QTH curing lights.
    Felix CA; Price RB; Andreou P
    J Can Dent Assoc; 2006 Mar; 72(2):147. PubMed ID: 16545176
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.