BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

121 related articles for article (PubMed ID: 18051242)

  • 1. Medical and technical protocol for automatic navigation of a wireless device in the carotid artery of a living swine using a standard clinical MRI system.
    Martel S; Mathieu JB; Felfoul O; Chanu A; Aboussouan E; Tamaz S; Pouponneau P; Yahia L; Beaudoin G; Soulez G; Mankiewicz M
    Med Image Comput Comput Assist Interv; 2007; 10(Pt 1):144-52. PubMed ID: 18051242
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A computer-assisted protocol for endovascular target interventions using a clinical MRI system for controlling untethered microdevices and future nanorobots.
    Martel S; Mathieu JB; Felfoul O; Chanu A; Aboussouan E; Tamaz S; Pouponneau P; Yahia L; Beaudoin G; Soulez G; Mankiewicz M
    Comput Aided Surg; 2008 Nov; 13(6):340-52. PubMed ID: 19031286
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Magnetic resonance propulsion, control and tracking at 24 Hz of an untethered device in the carotid artery of a living animal: an important step in the development of medical micro- and nanorobots.
    Martel S
    Annu Int Conf IEEE Eng Med Biol Soc; 2007; 2007():1475-8. PubMed ID: 18002245
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Adapting the clinical MRI software environment for real-time navigation of an endovascular untethered ferromagnetic bead for future endovascular interventions.
    Chanu A; Felfoul O; Beaudoin G; Martel S
    Magn Reson Med; 2008 Jun; 59(6):1287-97. PubMed ID: 18506794
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Real-time software platform design for in-vivo navigation of a small ferromagnetic device in a swine carotid artery using a magnetic resonance imaging system.
    Chanu A; Martel S
    Annu Int Conf IEEE Eng Med Biol Soc; 2007; 2007():6585-8. PubMed ID: 18003534
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Sequence design and software environment for real-time navigation of a wireless ferromagnetic device using MRI system and single echo 3D tracking.
    Chanu A; Aboussouan E; Tamaz S; Martel S
    Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():1746-9. PubMed ID: 17946065
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Robotics in MRI-Guided Interventions.
    Hata N; Moreira P; Fischer G
    Top Magn Reson Imaging; 2018 Feb; 27(1):19-23. PubMed ID: 29406411
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A catheter tracking method using reverse polarization for MR-guided interventions.
    Celik H; Ulutürk A; Tali T; Atalar E
    Magn Reson Med; 2007 Dec; 58(6):1224-31. PubMed ID: 18046701
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Software strategy for robotic transperineal prostate therapy in closed-bore MRI.
    Tokuda J; Fischer GS; Csoma C; DiMaio SP; Gobbi DG; Fichtinger G; Tempany CM; Hata N
    Med Image Comput Comput Assist Interv; 2008; 11(Pt 2):701-9. PubMed ID: 18982666
    [TBL] [Abstract][Full Text] [Related]  

  • 10. MRI compatibility of robot actuation techniques--a comparative study.
    Fischer GS; Krieger A; Iordachita I; Csoma C; Whitcomb LL; Gabor F
    Med Image Comput Comput Assist Interv; 2008; 11(Pt 2):509-17. PubMed ID: 18982643
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Principles of MR-guided interventions, surgery, navigation, and robotics].
    Melzer A
    Bundesgesundheitsblatt Gesundheitsforschung Gesundheitsschutz; 2010 Aug; 53(8):768-75. PubMed ID: 20700775
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Automatic navigation path generation based on two-phase adaptive region-growing algorithm for virtual angioscopy.
    Kim DY; Chung SM; Park JW
    Med Eng Phys; 2006 May; 28(4):339-47. PubMed ID: 16112889
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A prototype manipulator for magnetic resonance-guided interventions inside standard cylindrical magnetic resonance imaging scanners.
    Tsekos NV; Ozcan A; Christoforou E
    J Biomech Eng; 2005 Nov; 127(6):972-80. PubMed ID: 16438235
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Dynamic coil selection for real-time imaging in interventional MRI.
    Müller S; Umathum R; Speier P; Zühlsdorff S; Ley S; Semmler W; Bock M
    Magn Reson Med; 2006 Nov; 56(5):1156-62. PubMed ID: 17029224
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Method of propulsion of a ferromagnetic core in the cardiovascular system through magnetic gradients generated by an MRI system.
    Mathieu JB; Beaudoin G; Martel S
    IEEE Trans Biomed Eng; 2006 Feb; 53(2):292-9. PubMed ID: 16485758
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Automatic slice positioning (ASP) for passive real-time tracking of interventional devices using projection-reconstruction imaging with echo-dephasing (PRIDE).
    Patil S; Bieri O; Jhooti P; Scheffler K
    Magn Reson Med; 2009 Oct; 62(4):935-42. PubMed ID: 19585605
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Real-time multipoint gastrointestinal 19-fluorine catheter tracking.
    Hahn T; Kozerke S; Schwizer W; Fried M; Boesiger P; Steingoetter A
    Magn Reson Med; 2014 Jan; 71(1):302-7. PubMed ID: 23400935
    [TBL] [Abstract][Full Text] [Related]  

  • 18. MRI-Compatible Robotics.
    Gassert R; Burdet E; Chinzei K
    IEEE Eng Med Biol Mag; 2008; 27(3):12-4. PubMed ID: 18519176
    [No Abstract]   [Full Text] [Related]  

  • 19. A modular approach to MRI-compatible robotics: using robotic modules with interconnectable 1-DoF Stages.
    Elhawary H; Zivanovic A; Rea M; Davies BL; Besant C; McRobbie D; Desouza NM; Young I; Lamperth MU
    IEEE Eng Med Biol Mag; 2008; 27(3):35-41. PubMed ID: 18519180
    [No Abstract]   [Full Text] [Related]  

  • 20. Wireless Resonant Circuits Printed Using Aerosol Jet Deposition for MRI Catheter Tracking.
    Jordan CD; Thorne BRH; Wadhwa A; Losey AD; Ozhinsky E; Kondapavulur S; Fratello V; Moore T; Stillson C; Yee C; Watkins RD; Scott GC; Martin AJ; Zhang X; Wilson MW; Hetts SW
    IEEE Trans Biomed Eng; 2020 Mar; 67(3):876-882. PubMed ID: 31247538
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.