These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

125 related articles for article (PubMed ID: 18072115)

  • 21. Pneumatic tube-transported blood samples in lithium heparinate gel separator tubes may be more susceptible to haemolysis than blood samples in serum tubes.
    Böckel-Frohnhöfer N; Hübner U; Hummel B; Geisel J
    Scand J Clin Lab Invest; 2014 Oct; 74(7):599-602. PubMed ID: 24909156
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A pitfall of measuring lithium levels in neonates.
    Tanaka T; Moretti ME; Verjee ZH; Shupak M; Ivanyi KE; Ito S
    Ther Drug Monit; 2008 Dec; 30(6):752-4. PubMed ID: 19057375
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Elevated lithium level: a case and brief overview of lithium poisoning.
    Nordt SP; Cantrell FL
    Psychosom Med; 1999; 61(4):564-5. PubMed ID: 10443766
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Differential effect of blood collection tubes on total free fatty acids (FFA) and total triiodothyronine (TT3) concentration: a model for studying interference from tube constituents.
    Bowen RA; Vu C; Remaley AT; Hortin GL; Csako G
    Clin Chim Acta; 2007 Mar; 378(1-2):181-93. PubMed ID: 17234171
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Evaluation of BD Barricor™ Plasma Blood Collection Tube for Biochemical Tests.
    Kösem A; Topçuoğlu C; Sezer S; Cevher ŞK; Yenigün EC; Dede F; Turhan T
    Clin Lab; 2019 Dec; 65(12):. PubMed ID: 31850716
    [TBL] [Abstract][Full Text] [Related]  

  • 26. The quality of diagnostic testing may be impaired during shipment of lithium-heparin gel tubes.
    Da Rin G; Lippi G
    Clin Chem Lab Med; 2014 Nov; 52(11):1633-7. PubMed ID: 24960155
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Evaluation of the Greiner Bio-One serum separator BCA Fast Clot tube.
    Dimeski G; Johnston J; Masci PP; Zhao KN; Brown N
    Clin Chem Lab Med; 2017 Jul; 55(8):1135-1141. PubMed ID: 28076307
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Solution densities and estimated total protein contents associated with inappropriate flotation of separator gel in different blood collection tubes.
    Faught RC; Marshall J; Bornhorst J
    Arch Pathol Lab Med; 2011 Sep; 135(9):1081-4. PubMed ID: 21877989
    [TBL] [Abstract][Full Text] [Related]  

  • 29. The impact of different sample matrices in delayed measurement of glucose.
    Roccaforte V; Daves M; Platzgummer S; Lippi G
    Clin Biochem; 2016 Dec; 49(18):1412-1415. PubMed ID: 27567939
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Cellular content in plasma of Becton-Dickinson lithium-heparin tubes: cause of unreliable results in the IFCC-recommended lactate dehydrogenase method.
    Bakker AJ; Bakker A; Renting-Wiering H
    Ann Clin Biochem; 2006 Nov; 43(Pt 6):510-2. PubMed ID: 17132285
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Glucose variation in centrifuged serum and lithium-heparin gel tubes stored for up to 96 hours at room temperature or 4 °C.
    Balboni F; Burbui S; Lippi G
    Scand J Clin Lab Invest; 2018; 78(7-8):546-550. PubMed ID: 30755098
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Green-top test tubes and lithium concentration.
    Quattrocchi FP; May B; Ackerman L
    Drug Intell Clin Pharm; 1988 Jan; 22(1):79. PubMed ID: 3349925
    [No Abstract]   [Full Text] [Related]  

  • 33. Artificial Lithium Toxicity: A Case Report and Review of the Literature.
    Richman LS; Dzierba AL; Connolly KA; Bryan PM; Chandra S
    J Pharm Pract; 2015 Oct; 28(5):479-81. PubMed ID: 26072429
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Underestimation of unfractionated heparin therapy assessment due to platelet activation when using partial-draw (pediatric) citrate collection tubes.
    Desconclois C; Eschwège V; Proulle V; Boutekedjiret T; Dreyfus M; Toulon P
    Thromb Res; 2014 Nov; 134(5):1117-22. PubMed ID: 25248688
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Lithium heparinised blood-collection tubes give falsely low albumin results with an automated bromcresol green method in haemodialysis patients.
    Meng QH; Krahn J
    Clin Chem Lab Med; 2008; 46(3):396-400. PubMed ID: 18254716
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Impact of evacuated collection tube fill volume and mixing on routine coagulation testing using 2.5-ml (pediatric) tubes.
    Chuang J; Sadler MA; Witt DM
    Chest; 2004 Oct; 126(4):1262-6. PubMed ID: 15486391
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Effect of blood sample tubes on amiodarone and desethylamiodarone concentrations.
    Siebers RW; Chen CT; Ferguson RI; Maling TJ
    Ther Drug Monit; 1988; 10(3):349-51. PubMed ID: 3176114
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Suitability of collection tubes with separator gels for therapeutic drug monitoring.
    Koch TR; Platoff G
    Ther Drug Monit; 1990 May; 12(3):277-80. PubMed ID: 2349612
    [TBL] [Abstract][Full Text] [Related]  

  • 39. [The effect of tailored training courses in preanalytical procedures on the quality of laboratory results].
    Mäder-Porombka C; Homberg A; Hörster F; Brune M; Kilian S; Buckel B; Goldwasser R
    Z Evid Fortbild Qual Gesundhwes; 2020 Apr; 150-152():38-44. PubMed ID: 32291158
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Pre-analytical effects of different lithium heparin plasma separation tubes in the routine clinical chemistry laboratory.
    Brandhorst G; Engelmayer J; Götze S; Oellerich M; von Ahsen N
    Clin Chem Lab Med; 2011 Sep; 49(9):1473-7. PubMed ID: 21605014
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.