66 related articles for article (PubMed ID: 18076362)
1. Polyethylene glycol interference in the Immulite prolactin assay: treatment of the calibrators with polyethylene glycol does not improve diagnostic accuracy.
Rivero A
Clin Chem Lab Med; 2008; 46(2):296-7. PubMed ID: 18076362
[No Abstract] [Full Text] [Related]
2. Decision cut-off of the polyethylene glycol precipitation technique in screening for macroprolactinemia on Immulite 2000.
Rivero A; Alonso E; Grijalba A
Clin Chem Lab Med; 2004 May; 42(5):566-8. PubMed ID: 15202797
[No Abstract] [Full Text] [Related]
3. Is polyethylene glycol precipitation of hyperprolactinaemic samples required when using the Beckman Coulter DxI-800 prolactin assay?
Hawkins RC
Clin Chem Lab Med; 2012 Feb; 50(4):757-9. PubMed ID: 22505565
[No Abstract] [Full Text] [Related]
4. Macroprolactin on the Advia Centaur: experience with 409 patients over a three-year period.
Jassam NF; Paterson A; Lippiatt C; Barth JH
Ann Clin Biochem; 2009 Nov; 46(Pt 6):501-4. PubMed ID: 19850593
[TBL] [Abstract][Full Text] [Related]
5. Roche Elecsys Prolactin II assay: reactivity with macroprolactin compared with eight commercial assays for prolactin and determination of monomeric prolactin by precipitation with polyethylene glycol.
Fahie-Wilson M; Bieglmayer C; Kratzsch J; Nusbaumer C; Roth HJ; Zaninotto M; Plebani M; Hubbuch A; Schneider E
Clin Lab; 2007; 53(7-8):485-92. PubMed ID: 17821956
[TBL] [Abstract][Full Text] [Related]
6. Reporting of post-polyethylene glycol prolactin: precipitation by polyethylene glycol 6000 or polyethylene glycol 8000 will change reference intervals for monomeric prolactin.
Veljkovic K; Servedio D; Don-Wauchope AC
Ann Clin Biochem; 2012 Jul; 49(Pt 4):402-4. PubMed ID: 22619354
[TBL] [Abstract][Full Text] [Related]
7. Macroenzyme detection by polyethylene glycol precipitation.
Davidson DF; Watson DJ
Ann Clin Biochem; 2003 Sep; 40(Pt 5):514-20. PubMed ID: 14503988
[TBL] [Abstract][Full Text] [Related]
8. Thermal degradation of polyethylene glycol 6000 and its effect on the assay of macroprolactin.
Boughen L; Liggat J; Ellis G
Clin Biochem; 2010 Jun; 43(9):750-3. PubMed ID: 20303933
[TBL] [Abstract][Full Text] [Related]
9. Polyethylene glycol in conjunction with a second antibody for 24-hour radioimmunoassays of bovine prolactin and growth hormone.
Eisenman JR; Chew BP
J Dairy Sci; 1983 May; 66(5):1174-9. PubMed ID: 6875064
[TBL] [Abstract][Full Text] [Related]
10. Gross variability in the detection of prolactin in sera containing big big prolactin (macroprolactin) by commercial immunoassays.
Smith TP; Suliman AM; Fahie-Wilson MN; McKenna TJ
J Clin Endocrinol Metab; 2002 Dec; 87(12):5410-5. PubMed ID: 12466327
[TBL] [Abstract][Full Text] [Related]
11. Roche Elecsys Prolactin II assay: reactivity with macroprolactin compared with eight commercial assays for prolactin and determination of monomeric prolactin by precipitation with polyethylene glycol.
Fahie-Wilson M; Bieglmayer C; Kratzsch J; Nusbaumer C; Roth HJ; Zaninotto M; Plebani M; Hubbuch A; Schneider E
Clin Lab; 2007; 53(5-6):301-7. PubMed ID: 17605405
[TBL] [Abstract][Full Text] [Related]
12. Macroprolactinaemia in patients with hyperprolactinaemia: composition of macroprolactin and stability during long-term follow-up.
Hattori N; Ishihara T; Saiki Y; Shimatsu A
Clin Endocrinol (Oxf); 2010 Dec; 73(6):792-7. PubMed ID: 20874771
[TBL] [Abstract][Full Text] [Related]
13. Detection of molecular variants of prolactin in human serum, evaluation of a method based on ultrafiltration.
Landberg E; Wahlberg J; Rydén I; Arvidsson BM; Ekman B
Clin Chim Acta; 2007 Feb; 376(1-2):220-5. PubMed ID: 17027953
[TBL] [Abstract][Full Text] [Related]
14. False-positive polyethylene glycol precipitation tests for macroprolactin due to increased serum globulins.
Ram S; Harris B; Fernando JJ; Gama R; Fahie-Wilson M
Ann Clin Biochem; 2008 May; 45(Pt 3):256-9. PubMed ID: 18482912
[TBL] [Abstract][Full Text] [Related]
15. A new low-volume isosmotic polyethylene glycol solution plus bisacodyl versus split-dose 4 L polyethylene glycol for bowel cleansing prior to colonoscopy: a randomised controlled trial.
Cesaro P; Hassan C; Spada C; Petruzziello L; Vitale G; Costamagna G
Dig Liver Dis; 2013 Jan; 45(1):23-7. PubMed ID: 22917636
[TBL] [Abstract][Full Text] [Related]
16. Reference ranges for serum total and monomeric prolactin for the current generation Abbott Architect assay.
Whitehead SJ; Cornes MP; Ford C; Gama R
Ann Clin Biochem; 2015 Jan; 52(Pt 1):61-6. PubMed ID: 25074991
[TBL] [Abstract][Full Text] [Related]
17. Prolactin and macroprolactin: a case report of hyperprolactinaemia highlighting the interpretation of discrepant results.
Ismail AA; Walker PL; Fahie-Wilson MN; Jassam N; Barth JH
Ann Clin Biochem; 2003 May; 40(Pt 3):298-300. PubMed ID: 12803849
[TBL] [Abstract][Full Text] [Related]
18. The Beckman DxI 800 prolactin assay demonstrates superior specificity for monomeric prolactin.
Byrne B; O'Shea P; Barrett P; Tormey W
Clin Chem Lab Med; 2010 Feb; 48(2):205-8. PubMed ID: 19943807
[TBL] [Abstract][Full Text] [Related]
19. Should macroprolactin be measured in all hyperprolactinaemic sera?
McKenna TJ
Clin Endocrinol (Oxf); 2009 Oct; 71(4):466-9. PubMed ID: 19320649
[TBL] [Abstract][Full Text] [Related]
20. Reference intervals for six enzymes after polyethylene glycol precipitation and ultrafiltration.
Wyness SP; Hunsaker JJ; La'ulu SL; Roberts WL
Clin Chim Acta; 2011 May; 412(11-12):1161-2. PubMed ID: 21062625
[No Abstract] [Full Text] [Related]
[Next] [New Search]