These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

116 related articles for article (PubMed ID: 18087662)

  • 1. Use of Kirschner wires as endoscopic retractors.
    Aydin A; Güven E; Aydin HU; Erer M
    Aesthetic Plast Surg; 2008 Mar; 32(2):397-8. PubMed ID: 18087662
    [No Abstract]   [Full Text] [Related]  

  • 2. A simple device for safe use of Kirschner wires.
    Imran D; Mashhadi SA; Mandal A
    Plast Reconstr Surg; 2004 Jan; 113(1):457-8. PubMed ID: 14707686
    [No Abstract]   [Full Text] [Related]  

  • 3. Reconstruction of a chondrocutaneous auricular defect using a Kirschner wire.
    Cardoso JC; Vieira R; Freitas JD; Figueiredo A
    Dermatol Surg; 2009 Jun; 35(6):1001-4. PubMed ID: 19397654
    [No Abstract]   [Full Text] [Related]  

  • 4. Intravenous catheter as a wire sleeve during forefoot reconstruction.
    Jarrett GJ; Rongstad KM; Posick LP
    Foot Ankle Int; 1999 Jun; 20(6):397. PubMed ID: 10395345
    [No Abstract]   [Full Text] [Related]  

  • 5. [A manual boring device for Kirschner wires].
    Rieck B
    Handchir Mikrochir Plast Chir; 1998 Sep; 30(5):338-40. PubMed ID: 9816517
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Innovations in plastic surgery using cheap readily available materials in a resource poor environment - from CoRSU Uganda.
    Tustin H; Hodges AM
    J Plast Reconstr Aesthet Surg; 2012 May; 65(5):e136-7. PubMed ID: 22206615
    [No Abstract]   [Full Text] [Related]  

  • 7. Temporary mandibular stabilisation during reconstruction: an alternative technique.
    Mohindra A; Blanco-Guzman MM
    Br J Oral Maxillofac Surg; 2009 Jul; 47(5):399-400. PubMed ID: 19027999
    [No Abstract]   [Full Text] [Related]  

  • 8. Using a needle-nose vise grip to remove Kirschner wires.
    Marcus AM
    Am J Orthop (Belle Mead NJ); 2005 Sep; 34(9):414. PubMed ID: 16250479
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Inexpensive self-retaining retractor for minor surgical procedures.
    Pearl CB; Aguillon A; McLaughlin E; Yu J
    Ann Plast Surg; 2003 Dec; 51(6):633-5. PubMed ID: 14646666
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Review of the Use of Stainless Wires in Craniosynostosis Surgery.
    Natghian H; Song M; Wall S; Johnson D
    J Craniofac Surg; 2019; 30(2):550-553. PubMed ID: 30664558
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Complex fragmentation of the distal radial articular surface. Reconstruction with subchondral Kirschner wires and bone grafts].
    Pillukat T; Schädel-Höpfner M; Windolf J; Prommersberger KJ
    Unfallchirurg; 2013 Jul; 116(7):617-23. PubMed ID: 22706651
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Endoscopic brow and forehead fixation: all that and more.
    Niamtu J
    Plast Reconstr Surg; 2005 Jan; 115(1):357-8. PubMed ID: 15622302
    [No Abstract]   [Full Text] [Related]  

  • 13. [Plastic surgery in the United States of North America].
    MALBEC EF
    Prensa Med Argent; 1947 Apr; 34(16):725-9. PubMed ID: 20245028
    [No Abstract]   [Full Text] [Related]  

  • 14. [Mid-term results after scaphoid excision and four-corner wrist arthrodesis using K-wires for advanced carpal collapse].
    Winkler FJ; Borisch N; Rath B; Grifka J; Heers G
    Z Orthop Unfall; 2010 May; 148(3):332-7. PubMed ID: 20135616
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Kirschner wire pin tract infection rates between percutaneous and buried wires in treating metacarpal and phalangeal fractures.
    Rafique A; Ghani S; Sadiq M; Siddiqui IA
    J Coll Physicians Surg Pak; 2006 Aug; 16(8):518-20. PubMed ID: 16899179
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [A simple external fixator of Kirschner wires and electric clips for use on fingers].
    Schneider P
    Handchir Mikrochir Plast Chir; 1993 Sep; 25(5):262-9. PubMed ID: 8144074
    [TBL] [Abstract][Full Text] [Related]  

  • 17. New technique for endoscopically-assisted particulate graft reconstruction of the mandible.
    Ferretti C; Reyneke J; Heliotis M; Ripamonti U
    Br J Oral Maxillofac Surg; 2018 Jun; 56(5):430-432. PubMed ID: 29716749
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A simplified technique for bending Kirschner wires.
    Noak SK; Thornquest D; Wilson RC
    J Foot Ankle Surg; 1995; 34(1):89-90. PubMed ID: 7780400
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Use of Kirschner wires with eyelets for tension band wiring of olecranon fractures.
    Kim JY; Lee YH; Gong HS; Lee SL; Lee SK; Baek GH
    J Hand Surg Am; 2013 Sep; 38(9):1762-7. PubMed ID: 23849734
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Complications following tension-band fixation of patellar fractures with cannulated screws compared with Kirschner wires.
    Hoshino CM; Tran W; Tiberi JV; Black MH; Li BH; Gold SM; Navarro RA
    J Bone Joint Surg Am; 2013 Apr; 95(7):653-9. PubMed ID: 23553301
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.