126 related articles for article (PubMed ID: 1808798)
1. Accuracy of velocity and shear rate measurements using pulsed Doppler ultrasound: a comparison of signal analysis techniques.
Markou CP; Ku DN
Ultrasound Med Biol; 1991; 17(8):803-14. PubMed ID: 1808798
[TBL] [Abstract][Full Text] [Related]
2. Some characteristics of laminar flow velocity spectra detected by a 20 MHz pulsed ultrasound Doppler.
Brown TD; Gabel RH; Pedersen DR; Bell LD; Blair WF
J Biomech; 1985; 18(12):927-38. PubMed ID: 2934393
[TBL] [Abstract][Full Text] [Related]
3. Modern spectral analysis techniques for blood flow velocity and spectral measurements with pulsed Doppler ultrasound.
David JY; Jones SA; Giddens DP
IEEE Trans Biomed Eng; 1991 Jun; 38(6):589-96. PubMed ID: 1879848
[TBL] [Abstract][Full Text] [Related]
4. Measurement accuracy of the flow velocity in pulsed ultrasound Doppler velocimeter.
Kagiyama M; Ogasawara Y; Tadaoka S; Kajiya F
Ultrasound Med Biol; 1999 Oct; 25(8):1265-74. PubMed ID: 10576269
[TBL] [Abstract][Full Text] [Related]
5. Pulsatile velocity distribution and wall shear rate measurement using pulsed Doppler ultrasound.
Hughes PE; How TV
J Biomech; 1994 Jan; 27(1):103-10. PubMed ID: 8106531
[TBL] [Abstract][Full Text] [Related]
6. Dorsal aortic flow velocity in chick embryos of stage 16 to 28.
Ursem NT; Struijk PC; Poelmann RE; Gittenberger-de Groot AC; Wladimiroff JW
Ultrasound Med Biol; 2001 Jul; 27(7):919-24. PubMed ID: 11476925
[TBL] [Abstract][Full Text] [Related]
7. Simulation of Doppler ultrasound signals for a laminar, pulsatile, nonuniform flow.
Wendling F; Jones SA; Giddens DP
Ultrasound Med Biol; 1992; 18(2):179-93. PubMed ID: 1580014
[TBL] [Abstract][Full Text] [Related]
8. Pulsed Doppler ultrasound system for the measurement of velocity distributions and flow disturbances in arterial prostheses.
Black RA; How TV
J Biomed Eng; 1989 Jan; 11(1):35-42. PubMed ID: 2927098
[TBL] [Abstract][Full Text] [Related]
9. Development of velocity profiles and retrograde flow in the porcine abdominal aorta under different haemodynamic conditions.
Pedersen EM; Kim WY; Staalsen NH; Hasenkam JM; Nygaard H; Paulsen PK
Scand Cardiovasc J; 1999; 33(4):206-14. PubMed ID: 10517207
[TBL] [Abstract][Full Text] [Related]
10. A comparison of digital and analog methods of Doppler spectral analysis for quantifying flow.
Voyles WF; Altobelli SA; Fisher DC; Greene ER
Ultrasound Med Biol; 1985; 11(5):727-34. PubMed ID: 2932830
[TBL] [Abstract][Full Text] [Related]
11. Evaluation of human coronary blood flow with an 80 channel 20 MHz pulsed Doppler velocimeter and zero-cross and Fourier transform methods during cardiac surgery.
Kajiya F; Ogasawara Y; Tsujioka K; Nakai M; Goto M; Wada Y; Tadaoka S; Matsuoka S; Mito K; Fujiwara T
Circulation; 1986 Nov; 74(5 Pt 2):III53-60. PubMed ID: 2945678
[TBL] [Abstract][Full Text] [Related]
12. Performance of time-frequency representation techniques to measure blood flow turbulence with pulsed-wave Doppler ultrasound.
Cloutier G; Chen D; Durand LG
Ultrasound Med Biol; 2001 Apr; 27(4):535-50. PubMed ID: 11368865
[TBL] [Abstract][Full Text] [Related]
13. A comparison method for mean frequency estimators for Doppler ultrasound.
Brands PJ; Hoeks AP
Ultrason Imaging; 1992 Oct; 14(4):367-86. PubMed ID: 1296340
[TBL] [Abstract][Full Text] [Related]
14. A two-dimensional Doppler ultrasonic probe for flow measurement.
Ashrafzadeh AR; Dormer KJ; Cheung JY
Biomed Instrum Technol; 1989; 23(4):301-7. PubMed ID: 2529943
[TBL] [Abstract][Full Text] [Related]
15. 25 + 1 channel pulsed ultrasound Doppler velocity meter for quantitative flow measurements and turbulence analysis.
Casty M; Giddens DP
Ultrasound Med Biol; 1984; 10(2):161-72. PubMed ID: 6506326
[TBL] [Abstract][Full Text] [Related]
16. Noninvasive pulsed Doppler blood velocity measurements and calculated flow in human digital arteries.
Greene ER; Blair WF; Hartley C
ISA Trans; 1981; 20(2):15-24. PubMed ID: 7275568
[TBL] [Abstract][Full Text] [Related]
17. Accuracy of Doppler catheter measurements: effect of inhomogeneous beam power distribution on mean and peak velocity.
Denardo SJ; Talbot L; Hargrave VK; Selfridge AR; Ports TA; Yock PG
J Am Coll Cardiol; 1997 Feb; 29(2):283-92. PubMed ID: 9014979
[TBL] [Abstract][Full Text] [Related]
18. Studies by pulsed Doppler ultrasonography of velocity fields downstream of graded stenoses on the abdominal aorta in pigs.
Kim WY; Pedersen EM; Nygaard H; Sømod L; Hasenkam JM
J Vasc Surg; 1994 Mar; 19(3):414-25. PubMed ID: 8126854
[TBL] [Abstract][Full Text] [Related]
19. Pulsatile flow and oscillating wall shear stress in the brachial artery of normotensive and hypertensive subjects.
Simon AC; Levenson J; Flaud P
Cardiovasc Res; 1990 Feb; 24(2):129-36. PubMed ID: 2328518
[TBL] [Abstract][Full Text] [Related]
20. Differentiation of abnormal blood flow patterns in coronary arteries based on Doppler catheter recordings.
Denardo SJ; Yock PG; Hargrave VK; Srebro JP; Ports TA; Talbot L
Angiology; 1991 Sep; 42(9):711-25. PubMed ID: 1928812
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]