These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
1048 related articles for article (PubMed ID: 18093709)
1. The effect of on-body lift assistive device on the lumbar 3D dynamic moments and EMG during asymmetric freestyle lifting. Abdoli-E M; Stevenson JM Clin Biomech (Bristol); 2008 Mar; 23(3):372-80. PubMed ID: 18093709 [TBL] [Abstract][Full Text] [Related]
2. An on-body personal lift augmentation device (PLAD) reduces EMG amplitude of erector spinae during lifting tasks. Abdoli-E M; Agnew MJ; Stevenson JM Clin Biomech (Bristol); 2006 Jun; 21(5):456-65. PubMed ID: 16494978 [TBL] [Abstract][Full Text] [Related]
3. PLAD (personal lift assistive device) stiffness affects the lumbar flexion/extension moment and the posterior chain EMG during symmetrical lifting tasks. Frost DM; Abdoli-E M; Stevenson JM J Electromyogr Kinesiol; 2009 Dec; 19(6):e403-12. PubMed ID: 19200755 [TBL] [Abstract][Full Text] [Related]
4. The relationship between flexibility and EMG activity pattern of the erector spinae muscles during trunk flexion-extension. Hashemirad F; Talebian S; Hatef B; Kahlaee AH J Electromyogr Kinesiol; 2009 Oct; 19(5):746-53. PubMed ID: 18400517 [TBL] [Abstract][Full Text] [Related]
5. Torque and EMG in rotation extension of the torso from pre-rotated and flexed postures. Kumar S; Narayan Y Clin Biomech (Bristol); 2006 Nov; 21(9):920-31. PubMed ID: 16782246 [TBL] [Abstract][Full Text] [Related]
6. Mathematical and empirical proof of principle for an on-body personal lift augmentation device (PLAD). Abdoli-Eramaki M; Stevenson JM; Reid SA; Bryant TJ J Biomech; 2007; 40(8):1694-700. PubMed ID: 17466313 [TBL] [Abstract][Full Text] [Related]
7. Flexion relaxation during lifting: implications for torque production by muscle activity and tissue strain at the lumbo-sacral joint. Toussaint HM; de Winter AF; de Haas Y; de Looze MP; Van Dieën JH; Kingma I J Biomech; 1995 Feb; 28(2):199-210. PubMed ID: 7896862 [TBL] [Abstract][Full Text] [Related]
8. On neck muscle activity and load reduction in sitting postures. An electromyographic and biomechanical study with applications in ergonomics and rehabilitation. Schüldt K Scand J Rehabil Med Suppl; 1988; 19():1-49. PubMed ID: 3166203 [TBL] [Abstract][Full Text] [Related]
9. Different parts of erector spinae muscle fatigability in subjects with and without low back pain. Sung PS; Lammers AR; Danial P Spine J; 2009 Feb; 9(2):115-20. PubMed ID: 18280212 [TBL] [Abstract][Full Text] [Related]
10. The association of low back pain, neuromuscular imbalance, and trunk extension strength in athletes. Renkawitz T; Boluki D; Grifka J Spine J; 2006; 6(6):673-83. PubMed ID: 17088198 [TBL] [Abstract][Full Text] [Related]
11. Regional changes in spine posture at lift onset with changes in lift distance and lift style. Gill KP; Bennett SJ; Savelsbergh GJ; van Dieën JH Spine (Phila Pa 1976); 2007 Jul; 32(15):1599-604. PubMed ID: 17621206 [TBL] [Abstract][Full Text] [Related]
12. Wrapping of trunk thoracic extensor muscles influences muscle forces and spinal loads in lifting tasks. Arjmand N; Shirazi-Adl A; Bazrgari B Clin Biomech (Bristol); 2006 Aug; 21(7):668-75. PubMed ID: 16678948 [TBL] [Abstract][Full Text] [Related]
13. Dynamic versus static analyses of lifting a box from the floor. Menzer HM; Reiser RF Biomed Sci Instrum; 2005; 41():305-10. PubMed ID: 15850123 [TBL] [Abstract][Full Text] [Related]
14. Effect of instruction, surface stability, and load intensity on trunk muscle activity. Bressel E; Willardson JM; Thompson B; Fontana FE J Electromyogr Kinesiol; 2009 Dec; 19(6):e500-4. PubMed ID: 19054687 [TBL] [Abstract][Full Text] [Related]
15. Does the personal lift-assist device affect the local dynamic stability of the spine during lifting? Graham RB; Sadler EM; Stevenson JM J Biomech; 2011 Feb; 44(3):461-6. PubMed ID: 21030023 [TBL] [Abstract][Full Text] [Related]
16. Creep and fatigue development in the low back in static flexion. Shin G; D'Souza C; Liu YH Spine (Phila Pa 1976); 2009 Aug; 34(17):1873-8. PubMed ID: 19644340 [TBL] [Abstract][Full Text] [Related]
17. Electromyographic mapping of the erector spinae muscle with varying load and during sustained contraction. Tucker K; Falla D; Graven-Nielsen T; Farina D J Electromyogr Kinesiol; 2009 Jun; 19(3):373-9. PubMed ID: 18061480 [TBL] [Abstract][Full Text] [Related]
18. Intramuscular hemodynamics in bilateral erector spinae muscles in symmetrical and asymmetrical postures with and without loading. Masuda T; Miyamoto K; Shimizu K Clin Biomech (Bristol); 2006 Mar; 21(3):245-53. PubMed ID: 16364517 [TBL] [Abstract][Full Text] [Related]
19. Determination of trunk muscle forces for flexion and extension by using a validated finite element model of the lumbar spine and measured in vivo data. Rohlmann A; Bauer L; Zander T; Bergmann G; Wilke HJ J Biomech; 2006; 39(6):981-9. PubMed ID: 16549091 [TBL] [Abstract][Full Text] [Related]
20. Manual materials handling in mining: the effect of rod heights and foot positions when lifting "in-the-hole" drill rods. Plamondon A; Delisle A; Trimble K; Desjardins P; Rickwood T Appl Ergon; 2006 Nov; 37(6):709-18. PubMed ID: 16545338 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]