BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

330 related articles for article (PubMed ID: 18096097)

  • 1. Contrast transfer and resolution limits for sub-angstrom high-resolution transmission electron microscopy.
    Lentzen M
    Microsc Microanal; 2008 Feb; 14(1):16-26. PubMed ID: 18096097
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The tuning of a Zernike phase plate with defocus and variable spherical aberration and its use in HRTEM imaging.
    Lentzen M
    Ultramicroscopy; 2004 Jun; 99(4):211-20. PubMed ID: 15149715
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Seeing atoms with aberration-corrected sub-Angström electron microscopy.
    O'Keefe MA
    Ultramicroscopy; 2008 Feb; 108(3):196-209. PubMed ID: 18054170
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Progress in aberration-corrected high-resolution transmission electron microscopy using hardware aberration correction.
    Lentzen M
    Microsc Microanal; 2006 Jun; 12(3):191-205. PubMed ID: 17481356
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Linear versus non-linear structural information limit in high-resolution transmission electron microscopy.
    Van Aert S; Chen JH; Van Dyck D
    Ultramicroscopy; 2010 Oct; 110(11):1404-10. PubMed ID: 20655146
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Physical limits on atomic resolution.
    Van Dyck D; Van Aert S; den Dekker AJ
    Microsc Microanal; 2004 Feb; 10(1):153-7. PubMed ID: 15306080
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Direct sub-angstrom imaging of a crystal lattice.
    Nellist PD; Chisholm MF; Dellby N; Krivanek OL; Murfitt MF; Szilagyi ZS; Lupini AR; Borisevich A; Sides WH; Pennycook SJ
    Science; 2004 Sep; 305(5691):1741. PubMed ID: 15375260
    [TBL] [Abstract][Full Text] [Related]  

  • 8. High-resolution transmission electron microscopy using negative spherical aberration.
    Jia CL; Lentzen M; Urban K
    Microsc Microanal; 2004 Apr; 10(2):174-84. PubMed ID: 15306044
    [TBL] [Abstract][Full Text] [Related]  

  • 9. On the importance of fifth-order spherical aberration for a fully corrected electron microscope.
    Chang LY; Kirkland AI; Titchmarsh JM
    Ultramicroscopy; 2006 Mar; 106(4-5):301-6. PubMed ID: 16309838
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Atomic imaging in aberration-corrected high-resolution transmission electron microscopy.
    Chen JH; Zandbergen HW; Dyck DV
    Ultramicroscopy; 2004 Jan; 98(2-4):81-97. PubMed ID: 15046789
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Detection of single atoms and buried defects in three dimensions by aberration-corrected electron microscope with 0.5-A information limit.
    Kisielowski C; Freitag B; Bischoff M; van Lin H; Lazar S; Knippels G; Tiemeijer P; van der Stam M; von Harrach S; Stekelenburg M; Haider M; Uhlemann S; Müller H; Hartel P; Kabius B; Miller D; Petrov I; Olson EA; Donchev T; Kenik EA; Lupini AR; Bentley J; Pennycook SJ; Anderson IM; Minor AM; Schmid AK; Duden T; Radmilovic V; Ramasse QM; Watanabe M; Erni R; Stach EA; Denes P; Dahmen U
    Microsc Microanal; 2008 Oct; 14(5):469-77. PubMed ID: 18793491
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Optimum aberration coefficients for recording high-resolution off-axis holograms in a Cs-corrected TEM.
    Linck M
    Ultramicroscopy; 2013 Jan; 124():77-87. PubMed ID: 23142748
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Direct imaging of local atomic ordering in a Pd-Ni-P bulk metallic glass using Cs-corrected transmission electron microscopy.
    Hirata A; Hirotsu Y; Nieh TG; Ohkubo T; Tanaka N
    Ultramicroscopy; 2007; 107(2-3):116-23. PubMed ID: 16872747
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Study of point spread in the aberration-corrected transmission electron microscopy.
    Ge B; Wang Y; Chang Y; Yao Y
    Microsc Microanal; 2014 Oct; 20(5):1447-52. PubMed ID: 25256649
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A Contrast Transfer Function approach for image calculations in standard and aberration-corrected LEEM and PEEM.
    Schramm SM; Pang AB; Altman MS; Tromp RM
    Ultramicroscopy; 2012 Apr; 115():88-108. PubMed ID: 22209472
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effect of a physical phase plate on contrast transfer in an aberration-corrected transmission electron microscope.
    Gamm B; Schultheiss K; Gerthsen D; Schröder RR
    Ultramicroscopy; 2008 Aug; 108(9):878-84. PubMed ID: 18456408
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Atomic-resolution STEM in the aberration-corrected JEOL JEM2200FS.
    Klie RF; Johnson C; Zhu Y
    Microsc Microanal; 2008 Feb; 14(1):104-12. PubMed ID: 18171499
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Local crystal structure analysis with several picometer precision using scanning transmission electron microscopy.
    Kimoto K; Asaka T; Yu X; Nagai T; Matsui Y; Ishizuka K
    Ultramicroscopy; 2010 Jun; 110(7):778-82. PubMed ID: 20199847
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Future trends in aberration-corrected electron microscopy.
    Rose HH
    Philos Trans A Math Phys Eng Sci; 2009 Sep; 367(1903):3809-23. PubMed ID: 19687067
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Atomic resolution imaging of a carbon nanotube from diffraction intensities.
    Zuo JM; Vartanyants I; Gao M; Zhang R; Nagahara LA
    Science; 2003 May; 300(5624):1419-21. PubMed ID: 12775837
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 17.