These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
154 related articles for article (PubMed ID: 1812874)
1. Central venous pulsations associated with a falsely low oxygen saturation measured by pulse oximetry. Sami HM; Kleinman BS; Lonchyna VA J Clin Monit; 1991 Oct; 7(4):309-12. PubMed ID: 1812874 [TBL] [Abstract][Full Text] [Related]
2. Pulse oximetry in the pulmonary tissue for the non-invasive measurement of mixed venous oxygen saturation. Nitzan M; Nitzan I Med Hypotheses; 2013 Aug; 81(2):293-6. PubMed ID: 23679994 [TBL] [Abstract][Full Text] [Related]
3. The feasibility of transesophageal echocardiograph-guided right and left ventricular oximetry in hemodynamically stable patients undergoing coronary artery bypass grafting. Margreiter J; Keller C; Brimacombe J Anesth Analg; 2002 Apr; 94(4):794-8, table of contents. PubMed ID: 11916775 [TBL] [Abstract][Full Text] [Related]
4. Continuous intra-arterial oximetry, pulse oximetry, and co-oximetry during cardiac surgery. Haessler R; Brandl F; Zeller M; Briegel J; Peter K J Cardiothorac Vasc Anesth; 1992 Dec; 6(6):668-73. PubMed ID: 1472661 [TBL] [Abstract][Full Text] [Related]
5. Intra-aortic balloon counterpulsation in newborn lambs infected with group B streptococcus. Pribble CG; Shaddy RE ASAIO Trans; 1991; 37(1):33-7. PubMed ID: 2012717 [TBL] [Abstract][Full Text] [Related]
6. Effective arterial elastance and the hemodynamic effects of intraaortic balloon counterpulsation in patients with coronary heart disease. Marchionni N; Fumagalli S; Baldereschi G; Di Bari M; Fantini F Am Heart J; 1998 May; 135(5 Pt 1):855-61. PubMed ID: 9588417 [TBL] [Abstract][Full Text] [Related]
7. Comparison of central venous to mixed venous oxygen saturation in patients with low cardiac index and filling pressures after coronary artery surgery. Yazigi A; El Khoury C; Jebara S; Haddad F; Hayeck G; Sleilaty G J Cardiothorac Vasc Anesth; 2008 Feb; 22(1):77-83. PubMed ID: 18249335 [TBL] [Abstract][Full Text] [Related]
8. Central venous versus mixed venous oxygen content. Faber T Acta Anaesthesiol Scand Suppl; 1995; 107():33-6. PubMed ID: 8599294 [TBL] [Abstract][Full Text] [Related]
9. Arterial impedance in patients during intraaortic balloon counterpulsation. Kim SY; Euler DE; Jacobs WR; Montoya A; Sullivan HJ; Lonchyna VA; Pifarré R Ann Thorac Surg; 1996 Mar; 61(3):888-94. PubMed ID: 8619712 [TBL] [Abstract][Full Text] [Related]
10. Accuracy of pulse oximetry in patients with low systemic vascular resistance. Secker C; Spiers P Anaesthesia; 1997 Feb; 52(2):127-30. PubMed ID: 9059094 [TBL] [Abstract][Full Text] [Related]
11. Use of pulse oximetry to monitor venous saturation during extracorporeal life support. Odell RM; Doran RM; Erickson RC; Zeilinger TC; Coyle MG Crit Care Med; 1994 Apr; 22(4):626-32. PubMed ID: 8143472 [TBL] [Abstract][Full Text] [Related]
12. Multicenter study verifying a method of noninvasive continuous cardiac output measurement using pulse wave transit time: a comparison with intermittent bolus thermodilution cardiac output. Yamada T; Tsutsui M; Sugo Y; Sato T; Akazawa T; Sato N; Yamashita K; Ishihara H; Takeda J Anesth Analg; 2012 Jul; 115(1):82-7. PubMed ID: 22467885 [TBL] [Abstract][Full Text] [Related]
16. Maternal and fetal effects of laparoscopic insufflation in the gravid baboon. Reedy MB; Galan HL; Bean-Lijewski JD; Carnes A; Knight AB; Kuehl TJ J Am Assoc Gynecol Laparosc; 1995 Aug; 2(4):399-406. PubMed ID: 9050592 [TBL] [Abstract][Full Text] [Related]
17. Relationship between right atrial and mixed venous oxygen saturation and heart rate during exercise in normal subjects and patients with cardiac disease. French WJ; Casaburi R; Lewis DA; Daly JA; Florio J; Wesley GW Pacing Clin Electrophysiol; 1990 Dec; 13(12 Pt 2):1809-15. PubMed ID: 1704546 [TBL] [Abstract][Full Text] [Related]
18. The influence of simultaneous intra-aortic balloon pumping and mechanical ventilation on hemodynamic parameters--numerical simulation. Darowski M; De Lazzari C; Ferrari G; Clemente F; Guaragno M Front Med Biol Eng; 1999; 9(2):155-74. PubMed ID: 10450501 [TBL] [Abstract][Full Text] [Related]
19. A comparison of central and mixed venous oxygen saturation in circulatory failure. Ho KM; Harding R; Chamberlain J; Bulsara M J Cardiothorac Vasc Anesth; 2010 Jun; 24(3):434-9. PubMed ID: 18834813 [TBL] [Abstract][Full Text] [Related]
20. An uncalibrated pulse contour method to measure cardiac output during aortic counterpulsation. Scolletta S; Franchi F; Taccone FS; Donadello K; Biagioli B; Vincent JL Anesth Analg; 2011 Dec; 113(6):1389-95. PubMed ID: 22003226 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]