BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

169 related articles for article (PubMed ID: 18159972)

  • 1. Appropriate interval for repeat excision in women undergoing prior loop electrosurgical excision procedure for cervical neoplasia.
    Kietpeerakool C; Srisomboon J; Tiyayon J; Ruengkhachorn I; Cheewakriangkrai C; Suprasert P; Pantusart A
    Asian Pac J Cancer Prev; 2007; 8(3):379-82. PubMed ID: 18159972
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Perioperative complications of an outpatient loop electrosurgical excision procedure: a review of 857 consecutive cases.
    Sutthichon P; Kietpeerakool C
    Asian Pac J Cancer Prev; 2009; 10(3):351-4. PubMed ID: 19640171
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Repeat LEEP conization in patients with cervical intraepithelial neoplasia grade 3 and positive ectocervical margins.
    Ayhan A; Boynukalin FK; Guven S; Dogan NU; Esinler I; Usubutun A
    Int J Gynaecol Obstet; 2009 Apr; 105(1):14-7. PubMed ID: 19111301
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [LEEP versus cold knife conization for treatment of cervical intraepithelial neoplasias].
    Hillemanns P; Kimmig R; Dannecker C; Noorzai T; Diebold J; Thaler CJ; Hepp H
    Zentralbl Gynakol; 2000; 122(1):35-42. PubMed ID: 10785949
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Complications of loop electrosurgical excision procedure for cervical neoplasia: a prospective study.
    Kietpeerakool C; Srisomboon J; Khobjai A; Chandacham A; Tucksinsook U
    J Med Assoc Thai; 2006 May; 89(5):583-7. PubMed ID: 16756040
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The influence of time intervals between loop electrosurgical excision and subsequent hysterectomy on the morbidity of patients with cervical neoplasia.
    Tae Kim Y; Sung Yoon B; Hoon Kim S; Hoon Kim J; Wook Kim J; Won Park Y
    Gynecol Oncol; 2005 Feb; 96(2):500-3. PubMed ID: 15661242
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Cold knife conization vs. LEEP. Are they the same procedure?
    Fanning J; Padratzik J
    J Reprod Med; 2002 Jan; 47(1):33-5. PubMed ID: 11838307
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Assessment of cervical intraepithelial neoplasia (CIN) with colposcopic biopsy and efficacy of loop electrosurgical excision procedure (LEEP).
    Duesing N; Schwarz J; Choschzick M; Jaenicke F; Gieseking F; Issa R; Mahner S; Woelber L
    Arch Gynecol Obstet; 2012 Dec; 286(6):1549-54. PubMed ID: 22865036
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Loop Electrosurgical Excision Procedure Instead of Cold-Knife Conization for Cervical Intraepithelial Neoplasia in Women With Unsatisfactory Colposcopic Examinations: A Systematic Review and Meta-Analysis.
    El-Nashar SA; Shazly SA; Hopkins MR; Bakkum-Gamez JN; Famuyide AO
    J Low Genit Tract Dis; 2017 Apr; 21(2):129-136. PubMed ID: 27977541
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Impact of anaesthesia mode on evaluation of LEEP specimen dimensions.
    Mercuzot A; Chevreau J; Sevestre H; Muszynski C; Arbyn M; Sergent F; Gondry J
    J Gynecol Obstet Hum Reprod; 2017 Apr; 46(4):339-342. PubMed ID: 28643661
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Recurrence rate after loop electrosurgical excision procedure (LEEP) and laser Conization: A 5-year follow-up study.
    Bogani G; DI Donato V; Sopracordevole F; Ciavattini A; Ghelardi A; Lopez S; Simoncini T; Plotti F; Casarin J; Serati M; Pinelli C; Valenti G; Bergamini A; Gardella B; Dell'acqua A; Monti E; Vercellini P; Fischetti M; D'Ippolito G; Aguzzoli L; Mandato VD; Carunchio P; Carlinfante G; Giannella L; Scaffa C; Falcone F; Borghi C; Ditto A; Malzoni M; Giannini A; Salerno MG; Liberale V; Contino B; Donfrancesco C; Desiato M; Perrone AM; Dondi G; De Iaco P; Leone Roberti Maggiore U; Signorelli M; Chiappa V; Ferrero S; Sarpietro G; Matarazzo MG; Cianci A; Bosio S; Ruisi S; Guerrisi R; Brusadelli C; Mosca L; Tinelli R; DE Vincenzo R; Zannoni GF; Ferrandina G; Petrillo M; Dessole S; Angioli R; Greggi S; Spinillo A; Ghezzi F; Colacurci N; Muzii L; Benedetti Panici P; Scambia G; Raspagliesi F
    Gynecol Oncol; 2020 Dec; 159(3):636-641. PubMed ID: 32893030
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A Pilot Study to Investigate the Efficacy of Fibrin Sealant (TisseelĀ®) in the Loop Electrosurgical Excision Procedure.
    Kim JH; Park TC; Park GA; Song JY; Kim YH; Lee HJ; Lee SJ; Lee KH; Hur SY; Park JS
    Gynecol Obstet Invest; 2015; 80(1):21-5. PubMed ID: 25791173
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Diagnosis and treatment value of colposcopy and loop electrosurgical excision procedure in microinvasive cervical cancer: analysis of 135 cases].
    Xiao FY; Wang Q; Zheng RL; Chen M; Su TT; Sui L
    Zhonghua Fu Chan Ke Za Zhi; 2016 Mar; 51(3):186-91. PubMed ID: 27030497
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Outcome of loop electrosurgical excision for HIV-positive women in a low-resource outpatient setting.
    Kietpeerakool C; Suprasert P; Srisomboon J
    Int J Gynaecol Obstet; 2009 Apr; 105(1):10-3. PubMed ID: 19084838
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Conization by harmonic scalpel for cervical intraepithelial neoplasia: a clinicopathological study.
    Akahira J; Konno R; Moriya T; Yamakawa H; Igarashi T; Ito K; Sato S; Yajima A
    Gynecol Obstet Invest; 2000; 50(4):264-8. PubMed ID: 11093051
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Excisional treatment in women with cervical adenocarcinoma in situ (AIS): a prospective randomised controlled non-inferiority trial to compare AIS persistence/recurrence after loop electrosurgical excision procedure with cold knife cone biopsy: protocol for a pilot study.
    Cohen PA; Brand A; Sykes P; Wrede DCH; McNally O; Eva L; Rao A; Campion M; Stockler M; Powell A; Codde J; Bulsara MK; Anderson L; Leung Y; Farrell L; Stoyles P
    BMJ Open; 2017 Aug; 7(8):e017576. PubMed ID: 28851799
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Compliance after loop electrosurgical excision procedure or cold knife cone biopsy.
    Greenspan DL; Faubion M; Coonrod DV; Hart KW; Mathieson K
    Obstet Gynecol; 2007 Sep; 110(3):675-80. PubMed ID: 17766617
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Increase in the cervical length after the loop electrosurgical excision procedure for grade III cervical intraepithelial neoplasia.
    Chikazawa K; Netsu S; Akashi K; Suzuki Y; Konno R; Motomatsu S
    J Obstet Gynaecol; 2017 Jan; 37(1):78-81. PubMed ID: 27924675
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of LOOP electrosurgical excisional procedure: case series.
    Kazandi M; Oztekin K; Kazandi AC; Zekioglu O
    Eur J Gynaecol Oncol; 2010; 31(5):562-3. PubMed ID: 21061801
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Electrosurgical loop excision of the cervical transformation zone: the experience of family physicians.
    Ferris DG; Hainer BL; Pfenninger JL; Zuber TJ; DeWitt DE; Line RL
    J Fam Pract; 1995 Oct; 41(4):337-44. PubMed ID: 7561706
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.