These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

204 related articles for article (PubMed ID: 18165024)

  • 21. Alignment changes due to incomplete component seating in total knee arthroplasty.
    Cooper HJ
    J Arthroplasty; 2012 Jun; 27(6):1254-6. PubMed ID: 22480526
    [TBL] [Abstract][Full Text] [Related]  

  • 22. How accurate is Whiteside's line as a reference axis in total knee arthroplasty?
    Middleton FR; Palmer SH
    Knee; 2007 Jun; 14(3):204-7. PubMed ID: 17428665
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Varus/valgus alignment of the tibial component in total knee arthroplasty.
    Jeffcote B; Shakespeare D
    Knee; 2003 Sep; 10(3):243-7. PubMed ID: 12893146
    [TBL] [Abstract][Full Text] [Related]  

  • 24. The effect of alignment and BMI on failure of total knee replacement.
    Ritter MA; Davis KE; Meding JB; Pierson JL; Berend ME; Malinzak RA
    J Bone Joint Surg Am; 2011 Sep; 93(17):1588-96. PubMed ID: 21915573
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Femoral bow predicts postoperative malalignment in revision total knee arthroplasty.
    Sebastian AS; Wilke BK; Taunton MJ; Trousdale RT
    J Arthroplasty; 2014 Aug; 29(8):1605-9. PubMed ID: 24704122
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Intra-operative deviation in limb alignment occurring at implantation in total knee arthroplasty.
    Howie DF; Love GJ; Deakin AH; Kinninmonth AW
    Knee; 2015 Jan; 22(1):47-50. PubMed ID: 25476128
    [TBL] [Abstract][Full Text] [Related]  

  • 27. The effect of the posterior slope of the tibial plateau osteotomy with a rotational error on tibial component malalignment in total knee replacement.
    Tsukeoka T; Tsuneizumi Y; Lee TH
    Bone Joint J; 2013 Sep; 95-B(9):1201-3. PubMed ID: 23997132
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Arthrodesis of the knee using computer navigation in failed total knee arthroplasty.
    Jung KA; Lee SC; Song MB
    Orthopedics; 2009 Mar; 32(3):209. PubMed ID: 19309051
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Predicting the effect of tray malalignment on risk for bone damage and implant subsidence after total knee arthroplasty.
    Wong J; Steklov N; Patil S; Flores-Hernandez C; Kester M; Colwell CW; D'Lima DD
    J Orthop Res; 2011 Mar; 29(3):347-53. PubMed ID: 20882595
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Factors affecting the impingement angle of fixed- and mobile-bearing total knee replacements: a laboratory study.
    Walker PS; Yildirim G; Sussman-Fort J; Roth J; White B; Klein GR
    J Arthroplasty; 2007 Aug; 22(5):745-52. PubMed ID: 17689786
    [TBL] [Abstract][Full Text] [Related]  

  • 31. A comparison of accuracy between step and non-step reamers of femoral intramedullary alignment system in total knee arthroplasty evaluated by computer-assisted navigation.
    Vanasbodeekul P; Chotanaphuti T; Rattanaprichavej P; Wangwittayakul V
    J Med Assoc Thai; 2012 Oct; 95 Suppl 10():S72-6. PubMed ID: 23451442
    [TBL] [Abstract][Full Text] [Related]  

  • 32. [Mathematical analysis of the influences of femoral and tibial bone cuts on the dynamic alignment in total knee arthroplasty].
    Zhao Y; Wang S; Zhao Z; Song K; Zhang S
    Zhonghua Wai Ke Za Zhi; 2016 Apr; 54(4):241-6. PubMed ID: 27029196
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Angled polyethylene insert exchange for sagittal tibial malalignment in total knee arthroplasty.
    Sah AP; Scott RD; Iorio R
    J Arthroplasty; 2008 Jan; 23(1):141-4. PubMed ID: 18165044
    [TBL] [Abstract][Full Text] [Related]  

  • 34. A comparison of rotational landmarks in the distal femur and the tibial shaft.
    Matsuda S; Miura H; Nagamine R; Urabe K; Mawatari T; Iwamoto Y
    Clin Orthop Relat Res; 2003 Sep; (414):183-8. PubMed ID: 12966292
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Tibial tray rotation and posterior slope increase risk for outliers in coronal alignment.
    D'Lima DP; Huang P; Suryanarayan P; Rosen A; D'Lima DD
    Bone Joint J; 2020 Jun; 102-B(6_Supple_A):43-48. PubMed ID: 32475266
    [TBL] [Abstract][Full Text] [Related]  

  • 36. [Medin modular implant for total knee arthroplasty--mid-term results].
    Vavrík P; Landor I; Tomaides J; Popelka S
    Acta Chir Orthop Traumatol Cech; 2009 Feb; 76(1):30-4. PubMed ID: 19268046
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Midflexion instability in revision total knee arthroplasty.
    McPherson EJ; Cuckler J; Lombardi AV
    Surg Technol Int; 2008; 17():249-52. PubMed ID: 18802910
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Precise landmarking in computer assisted total knee arthroplasty is critical to final alignment.
    Brin YS; Livshetz I; Antoniou J; Greenberg-Dotan S; Zukor DJ
    J Orthop Res; 2010 Oct; 28(10):1355-9. PubMed ID: 20309860
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Improving tibial component coronal alignment during total knee arthroplasty with use of a tibial planing device.
    Patil S; D'Lima DD; Fait JM; Colwell CW
    J Bone Joint Surg Am; 2007 Feb; 89(2):381-7. PubMed ID: 17272454
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Tibial post impingement in posterior-stabilized total knee arthroplasty.
    Haas BD
    Orthopedics; 2006 Sep; 29(9 Suppl):S83-5. PubMed ID: 17002158
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 11.