These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Variability in effective radiating area at 1 MHz affects ultrasound treatment intensity. Straub SJ; Johns LD; Howard SM Phys Ther; 2008 Jan; 88(1):50-7. PubMed ID: 17940107 [TBL] [Abstract][Full Text] [Related]
3. [Metrological problems in testing medical ultrasound equipment]. Eniakov AM Med Tekh; 2001; (3):20-1. PubMed ID: 11515262 [TBL] [Abstract][Full Text] [Related]
4. Variability in effective radiating area and output power of new ultrasound transducers at 3 MHz. Johns LD; Straub SJ; Howard SM J Athl Train; 2007; 42(1):22-8. PubMed ID: 17597939 [TBL] [Abstract][Full Text] [Related]
5. Thermoacoustic sensor for ultrasound power measurements and ultrasonic equipment calibration. Fay B; Rinker M; Lewin PA Ultrasound Med Biol; 1994; 20(4):367-73. PubMed ID: 8085293 [TBL] [Abstract][Full Text] [Related]
6. Transfer standard device to improve the traceable calibration of physiotherapy ultrasound machines. Hekkenberg RT; Richards A; Beissner K; Zeqiri B; Bezemer RA; Hodnett M; Prout G; Cantrall C Ultrasound Med Biol; 2006 Sep; 32(9):1423-9. PubMed ID: 16965982 [TBL] [Abstract][Full Text] [Related]
7. Image-guided 256-element phased-array focused ultrasound surgery. Lu M; Wang X; Wan M; Feng Y; Xu F; Zhong H; Tan J IEEE Eng Med Biol Mag; 2008; 27(5):84-90. PubMed ID: 18799395 [No Abstract] [Full Text] [Related]
9. The performance of ultrasound physiotherapy machines in Lothian Region, Scotland, 1992. Pye SD; Milford C Ultrasound Med Biol; 1994; 20(4):347-59. PubMed ID: 8085291 [TBL] [Abstract][Full Text] [Related]
10. A method for measurement of frequency, modulation characteristics and timer accuracy of ultrasonic therapy equipment. Harris GR Med Instrum; 1975; 9(4):192-4. PubMed ID: 1143123 [TBL] [Abstract][Full Text] [Related]
11. Calibration and measurement issues for therapeutic ultrasound. Shaw A; Hodnett M Ultrasonics; 2008 Aug; 48(4):234-52. PubMed ID: 18234261 [TBL] [Abstract][Full Text] [Related]
12. Troubleshooting therapeutic ultrasound: measuring output power and caring for transducers. Fanning J Biomed Instrum Technol; 2005; 39(4):278-9. PubMed ID: 16111402 [No Abstract] [Full Text] [Related]
13. [Key technologies in HIFU treatment machine development]. Fan LZ; Luo F; Yu DY; Liu XT; Zhang J; Xie MX Zhongguo Yi Liao Qi Xie Za Zhi; 2005 Mar; 29(2):115-9. PubMed ID: 16011117 [TBL] [Abstract][Full Text] [Related]
14. Cryoultrasonic and cryogenic equipment for medicine. Vedenkov VG; Zholobov NI; Ptukha TP; Cyganov DI; Luniakov SA Med Prog Technol; 1992; 18(1-2):47-54. PubMed ID: 1388233 [TBL] [Abstract][Full Text] [Related]
15. Evaluation of a novel solid-state method for determining the acoustic power generated by physiotherapy ultrasound transducers. Zeqiri B; Barrie J Ultrasound Med Biol; 2008 Sep; 34(9):1513-27. PubMed ID: 18440695 [TBL] [Abstract][Full Text] [Related]
16. Morphological analysis of the interstitial ultrasonic ablation in porcine liver in vivo. Seket B; Lafon C; Salomir R; Chapelon JY; Paquet C; Scoazec JY; Cathignol D Eur Surg Res; 2008; 41(1):24-32. PubMed ID: 18401178 [TBL] [Abstract][Full Text] [Related]
17. Review of current IEC activities in acoustic output standardization of medical ultrasonic equipment. Preston RC Ultrasound Med Biol; 1989; 15 Suppl 1():101-3. PubMed ID: 2672504 [No Abstract] [Full Text] [Related]
18. [Ultrasonic equipment: status and development trends]. Chevnenko AA; Florianovich NM; Leont'ev AP Med Tekh; 1981; (2):28-30. PubMed ID: 7266309 [No Abstract] [Full Text] [Related]
19. Sensitivity of effective radiating area measurement for therapeutic ultrasound transducers to variations in hydrophone scanning technique. Bly SH; Hussey RG; Kingsley JP; Dickson AW Health Phys; 1989 Oct; 57(4):637-43. PubMed ID: 2793480 [TBL] [Abstract][Full Text] [Related]
20. Investigation of the viscous heating artefact arising from the use of thermocouples in a focused ultrasound field. Morris H; Rivens I; Shaw A; Haar GT Phys Med Biol; 2008 Sep; 53(17):4759-76. PubMed ID: 18701773 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]