BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

638 related articles for article (PubMed ID: 18171499)

  • 1. Atomic-resolution STEM in the aberration-corrected JEOL JEM2200FS.
    Klie RF; Johnson C; Zhu Y
    Microsc Microanal; 2008 Feb; 14(1):104-12. PubMed ID: 18171499
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Experimental evaluation of a spherical aberration-corrected TEM and STEM.
    Sawada H; Tomita T; Naruse M; Honda T; Hambridge P; Hartel P; Haider M; Hetherington C; Doole R; Kirkland A; Hutchison J; Titchmarsh J; Cockayne D
    J Electron Microsc (Tokyo); 2005 Apr; 54(2):119-21. PubMed ID: 15972729
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Performance of low-voltage STEM/TEM with delta corrector and cold field emission gun.
    Sasaki T; Sawada H; Hosokawa F; Kohno Y; Tomita T; Kaneyama T; Kondo Y; Kimoto K; Sato Y; Suenaga K
    J Electron Microsc (Tokyo); 2010 Aug; 59 Suppl 1():S7-13. PubMed ID: 20581425
    [TBL] [Abstract][Full Text] [Related]  

  • 4. First experimental test of a new monochromated and aberration-corrected 200 kV field-emission scanning transmission electron microscope.
    Walther T; Quandt E; Stegmann H; Thesen A; Benner G
    Ultramicroscopy; 2006; 106(11-12):963-9. PubMed ID: 16870338
    [TBL] [Abstract][Full Text] [Related]  

  • 5. STEM imaging of 47-pm-separated atomic columns by a spherical aberration-corrected electron microscope with a 300-kV cold field emission gun.
    Sawada H; Tanishiro Y; Ohashi N; Tomita T; Hosokawa F; Kaneyama T; Kondo Y; Takayanagi K
    J Electron Microsc (Tokyo); 2009 Dec; 58(6):357-61. PubMed ID: 19546144
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The formation and utility of sub-angstrom to nanometer-sized electron probes in the aberration-corrected transmission electron microscope at the University of Illinois.
    Wen J; Mabon J; Lei C; Burdin S; Sammann E; Petrov I; Shah AB; Chobpattana V; Zhang J; Ran K; Zuo JM; Mishina S; Aoki T
    Microsc Microanal; 2010 Apr; 16(2):183-93. PubMed ID: 20187990
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Progress in aberration-corrected high-resolution transmission electron microscopy using hardware aberration correction.
    Lentzen M
    Microsc Microanal; 2006 Jun; 12(3):191-205. PubMed ID: 17481356
    [TBL] [Abstract][Full Text] [Related]  

  • 8. High-resolution TEM and the application of direct and indirect aberration correction.
    Hetherington CJ; Chang LY; Haigh S; Nellist PD; Gontard LC; Dunin-Borkowski RE; Kirkland AI
    Microsc Microanal; 2008 Feb; 14(1):60-7. PubMed ID: 18171500
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Facility implementation and comparative performance evaluation of probe-corrected TEM/STEM with Schottky and cold field emission illumination.
    Xin Y; Kynoch J; Han K; Liang Z; Lee PJ; Larbalestier DC; Su YF; Nagahata K; Aoki T; Longo P
    Microsc Microanal; 2013 Apr; 19(2):487-95. PubMed ID: 23458469
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Aberration-corrected STEM/TEM imaging at 15kV.
    Sasaki T; Sawada H; Hosokawa F; Sato Y; Suenaga K
    Ultramicroscopy; 2014 Oct; 145():50-5. PubMed ID: 24842229
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Direct imaging of local atomic ordering in a Pd-Ni-P bulk metallic glass using Cs-corrected transmission electron microscopy.
    Hirata A; Hirotsu Y; Nieh TG; Ohkubo T; Tanaka N
    Ultramicroscopy; 2007; 107(2-3):116-23. PubMed ID: 16872747
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Prerequisites for a Cc/Cs-corrected ultrahigh-resolution TEM.
    Haider M; Müller H; Uhlemann S; Zach J; Loebau U; Hoeschen R
    Ultramicroscopy; 2008 Feb; 108(3):167-78. PubMed ID: 18060700
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Characterizing the two- and three-dimensional resolution of an improved aberration-corrected STEM.
    Lupini AR; Borisevich AY; Idrobo JC; Christen HM; Biegalski M; Pennycook SJ
    Microsc Microanal; 2009 Oct; 15(5):441-53. PubMed ID: 19754980
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A versatile double aberration-corrected, energy filtered HREM/STEM for materials science.
    Hutchison JL; Titchmarsh JM; Cockayne DJ; Doole RC; Hetherington CJ; Kirkland AI; Sawada H
    Ultramicroscopy; 2005 Apr; 103(1):7-15. PubMed ID: 15777595
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Electron holography with a Cs-corrected transmission electron microscope.
    Geiger D; Lichte H; Linck M; Lehmann M
    Microsc Microanal; 2008 Feb; 14(1):68-81. PubMed ID: 18096096
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Performance and image analysis of the aberration-corrected Hitachi HD-2700C STEM.
    Inada H; Wu L; Wall J; Su D; Zhu Y
    J Electron Microsc (Tokyo); 2009 Jun; 58(3):111-22. PubMed ID: 19254916
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Development of a monochromator for aberration-corrected scanning transmission electron microscopy.
    Mukai M; Okunishi E; Ashino M; Omoto K; Fukuda T; Ikeda A; Somehara K; Kaneyama T; Saitoh T; Hirayama T; Ikuhara Y
    Microscopy (Oxf); 2015 Jun; 64(3):151-8. PubMed ID: 25654985
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Atomic imaging in aberration-corrected high-resolution transmission electron microscopy.
    Chen JH; Zandbergen HW; Dyck DV
    Ultramicroscopy; 2004 Jan; 98(2-4):81-97. PubMed ID: 15046789
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Aberration-corrected ADF-STEM depth sectioning and prospects for reliable 3D imaging in S/TEM.
    Xin HL; Muller DA
    J Electron Microsc (Tokyo); 2009 Jun; 58(3):157-65. PubMed ID: 19164489
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Probing structures of nanomaterials using advanced electron microscopy methods, including aberration-corrected electron microscopy at the Angstrom scale.
    Gai PL; Yoshida K; Shute C; Jia X; Walsh M; Ward M; Dresselhaus MS; Weertman JR; Boyes ED
    Microsc Res Tech; 2011 Jul; 74(7):664-70. PubMed ID: 20954265
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 32.