1347 related articles for article (PubMed ID: 18175022)
1. Equivalency of a personal dust monitor to the current United States coal mine respirable dust sampler.
Page SJ; Volkwein JC; Vinson RP; Joy GJ; Mischler SE; Tuchman DP; McWilliams LJ
J Environ Monit; 2008 Jan; 10(1):96-101. PubMed ID: 18175022
[TBL] [Abstract][Full Text] [Related]
2. A revised conversion factor relating respirable dust concentrations measured by 10 mm Dorr-Oliver nylon cyclones operated at 1.7 and 2.0 L min(-1).
Page SJ; Volkwein JC
J Environ Monit; 2009 Mar; 11(3):684-9. PubMed ID: 19280048
[TBL] [Abstract][Full Text] [Related]
3. Determining the spatial variability of personal sampler inlet locations.
Vinson R; Volkwein J; McWilliams L
J Occup Environ Hyg; 2007 Sep; 4(9):708-14. PubMed ID: 17654226
[TBL] [Abstract][Full Text] [Related]
4. Testing a revised inlet for the personal dust monitor.
Mischler SE; Tuchman DP; Cauda EG; Colinet JF; Rubinstein EN
J Occup Environ Hyg; 2019 Mar; 16(3):242-249. PubMed ID: 30620243
[TBL] [Abstract][Full Text] [Related]
5. Comparison of mass concentrations determined with personal respirable coal mine dust samplers operating at 1.2 liters per minute and the Casella 113A gravimetric sampler (MRE).
Treaftis HN; Gero AJ; Kacsmar PM; Tomb TF
Am Ind Hyg Assoc J; 1984 Dec; 45(12):826-32. PubMed ID: 6517028
[TBL] [Abstract][Full Text] [Related]
6. Estimation of respirable dust exposure among coal miners in South Africa.
Naidoo R; Seixas N; Robins T
J Occup Environ Hyg; 2006 Jun; 3(6):293-300. PubMed ID: 16621766
[TBL] [Abstract][Full Text] [Related]
7. High exposure to respirable dust and quartz in a labour-intensive coal mine in Tanzania.
Mamuya SH; Bråtveit M; Mwaiselage J; Mashalla YJ; Moen BE
Ann Occup Hyg; 2006 Mar; 50(2):197-204. PubMed ID: 16143714
[TBL] [Abstract][Full Text] [Related]
8. Laboratory and field testing of sampling methods for inhalable and respirable dust.
Linnainmaa M; Laitinen J; Leskinen A; Sippula O; Kalliokoski P
J Occup Environ Hyg; 2008 Jan; 5(1):28-35. PubMed ID: 18041642
[TBL] [Abstract][Full Text] [Related]
9. Implementing infrared determination of quartz particulates on novel filters for a prototype dust monitor.
Tuchman DP; Volkwein JC; Vinson RP
J Environ Monit; 2008 May; 10(5):671-8. PubMed ID: 18449405
[TBL] [Abstract][Full Text] [Related]
10. Variability of exposure and estimation of cumulative exposure in a manually operated coal mine.
Mamuya SH; Bråtveit M; Mwaiselage J; Moen BE
Ann Occup Hyg; 2006 Oct; 50(7):737-45. PubMed ID: 16777910
[TBL] [Abstract][Full Text] [Related]
11. A critique of MSHA procedures for determination of permissible respirable coal mine dust containing free silica.
Corn M; Breysse P; Hall T; Chen G; Risby T; Swift DL
Am Ind Hyg Assoc J; 1985 Jan; 46(1):4-8. PubMed ID: 2992262
[TBL] [Abstract][Full Text] [Related]
12. [Exposure to silica dust in coal-mining. Analysis based on measurements made by industrial hygiene laboratories in Poland, 2001-2005].
Mikołajczyk U; Bujak-Pietrek S; Szadkowska-Stańczyk I
Med Pr; 2010; 61(3):287-97. PubMed ID: 20677428
[TBL] [Abstract][Full Text] [Related]
13. Redesign of a static horizontal elutriator to perform according to the ISO 7708 respirable convention.
Myojo T; Oyabu T; Kuroda K; Kadoya C; Nishi K; Tanaka I
Ann Occup Hyg; 2007 Jun; 51(4):371-8. PubMed ID: 17456582
[TBL] [Abstract][Full Text] [Related]
14. Application of PUF foam inserts for respirable dust measurements in the brick-manufacturing industry.
De Vocht F; Hirst A; Gardner A
Ann Occup Hyg; 2009 Jan; 53(1):19-25. PubMed ID: 18977848
[TBL] [Abstract][Full Text] [Related]
15. Quantitating the efficiency of the coal mine personal respirable dust sampler for sampling oxide fumes.
Tomb TF; Beckert AJ; Treaftis HN
Am Ind Hyg Assoc J; 1976 Aug; 37(8):459-63. PubMed ID: 970321
[TBL] [Abstract][Full Text] [Related]
16. Comparison of respirable coal mine dust concentrations measured with an MRE and a newly-developed, two-stage impactor sampler.
Treaftis HN; Tomb TF; Taylor CD
Am Ind Hyg Assoc J; 1978 Nov; 39(11):891-7. PubMed ID: 736001
[TBL] [Abstract][Full Text] [Related]
17. The evaluation and quantification of respirable coal and silica dust concentrations: a task-based approach.
Grové T; Van Dyk T; Franken A; Du Plessis J
J Occup Environ Hyg; 2014; 11(6):406-14. PubMed ID: 24380473
[TBL] [Abstract][Full Text] [Related]
18. Comparison of portable, real-time dust monitors sampling actively, with size-selective adaptors, and passively.
Thorpe A; Walsh PT
Ann Occup Hyg; 2007 Nov; 51(8):679-91. PubMed ID: 18024485
[TBL] [Abstract][Full Text] [Related]
19. Variability of particle size-specific fractions of personal coal mine dust exposures.
Seixas NS; Hewett P; Robins TG; Haney R
Am Ind Hyg Assoc J; 1995 Mar; 56(3):243-50. PubMed ID: 7717269
[TBL] [Abstract][Full Text] [Related]
20. The derivation of estimated dust exposures for U.S. coal miners working before 1970.
Attfield MD; Morring K
Am Ind Hyg Assoc J; 1992 Apr; 53(4):248-55. PubMed ID: 1529917
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]