375 related articles for article (PubMed ID: 18187241)
1. Tension band wire fixation for valgus osteotomies of the proximal femur: a biomechanical study of three configurations of fixation.
Volpon JB; Batista LC; Shimano MM; Moro CA
Clin Biomech (Bristol, Avon); 2008 May; 23(4):395-401. PubMed ID: 18187241
[TBL] [Abstract][Full Text] [Related]
2. Mechanical testing of the tension band wire fixation in the proximal femur.
Engel EE; Volpon JB; Shimano AC
Arch Orthop Trauma Surg; 1997; 116(5):266-70. PubMed ID: 9177801
[TBL] [Abstract][Full Text] [Related]
3. Four-point bending strength of transverse osteotomies stabilized with various Kirschner wire and tension wire band configurations.
Pehlivan O; Kiral A; Mahirogullari M; Koksal O; Kaplan H
J Hand Surg Br; 2005 Aug; 30(4):428-31. PubMed ID: 15935530
[TBL] [Abstract][Full Text] [Related]
4. The effect of transfixion wire crossing angle on the stiffness of fine wire external fixation: a biomechanical study.
Roberts CS; Antoci V; Antoci V; Voor MJ
Injury; 2005 Sep; 36(9):1107-12. PubMed ID: 16098336
[TBL] [Abstract][Full Text] [Related]
5. Biomechanical analysis of screw fixation vs. K-wire fixation of a slipped capital femoral epiphysis model.
Druschel C; Sawicki O; Cip J; Schmölz W; Funk JF; Placzek R
Biomed Tech (Berl); 2012 May; 57(3):157-62. PubMed ID: 22691422
[TBL] [Abstract][Full Text] [Related]
6. Mechanical testing of seven fixation methods for generation of compression across a midtarsal osteotomy: a comparison of internal and external fixation devices.
Grant WP; Rubin LG; Pupp GR; Vito G; Jacobus D; Jerlin EA; Tam HS
J Foot Ankle Surg; 2007; 46(5):325-35. PubMed ID: 17761316
[TBL] [Abstract][Full Text] [Related]
7. Mechanical performance of Ilizarov circular external fixators in comparison with other external fixators.
Podolsky A; Chao EY
Clin Orthop Relat Res; 1993 Aug; (293):61-70. PubMed ID: 8339510
[TBL] [Abstract][Full Text] [Related]
8. Open wedge high tibial osteotomy: biomechanical investigation of the modified Arthrex Osteotomy Plate (Puddu Plate) and the TomoFix Plate.
Stoffel K; Stachowiak G; Kuster M
Clin Biomech (Bristol, Avon); 2004 Nov; 19(9):944-50. PubMed ID: 15475127
[TBL] [Abstract][Full Text] [Related]
9. The effects of wire diameter and an additional lateral wire on pin and tension-band fixation subjected to cyclic loads.
Neat B; Kowaleski MP; Litsky AS; Boudrieau RJ
Vet Comp Orthop Traumatol; 2006; 19(4):213-8. PubMed ID: 17143393
[TBL] [Abstract][Full Text] [Related]
10. Biomechanical comparison of fixation of two-part osteoporotic neck fracture of the proximal humerus using uni-planar and multi-planar Kirschner wire.
Esen E; Doğramaci Y; Kömürcü M; Kanatli U; Bölükbaşi S; Atahan AO
Eklem Hastalik Cerrahisi; 2009; 20(2):114-8. PubMed ID: 19619116
[TBL] [Abstract][Full Text] [Related]
11. Biomechanical investigation of different internal fixations in medial opening-wedge high tibial osteotomy.
Spahn G; Mückley T; Kahl E; Hofmann GO
Clin Biomech (Bristol, Avon); 2006 Mar; 21(3):272-8. PubMed ID: 16337721
[TBL] [Abstract][Full Text] [Related]
12. [A biomechanical study on different fixation of cortical bone plate allograft].
Zhang R; Liao Y; Li B
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2007 Aug; 21(8):793-6. PubMed ID: 17882869
[TBL] [Abstract][Full Text] [Related]
13. [Evaluation of biomechanical rigidity of K-wire configurations in transverse osteotomies: a comparison of four-point bending test results].
Pehlivan O; Yilmaz S; Kiral A; Akmaz I; Mahiroğullari M; Kaplan H
Acta Orthop Traumatol Turc; 2003; 37(5):395-9. PubMed ID: 14963396
[TBL] [Abstract][Full Text] [Related]
14. Effect of wire tension on stiffness of tensioned fine wires in external fixation: a mechanical study.
Antoci V; Voor MJ; Antoci V; Roberts CS
Am J Orthop (Belle Mead NJ); 2007 Sep; 36(9):473-6. PubMed ID: 17948150
[TBL] [Abstract][Full Text] [Related]
15. [Two different methods of supracondylar lateral wedge osteotomy in cubitus varus deformity in adults].
Kalaci A; Ozkan C; Yanat AN; Oney T; Sever G; Doğramaci Y
Eklem Hastalik Cerrahisi; 2009; 20(3):136-42. PubMed ID: 19958269
[TBL] [Abstract][Full Text] [Related]
16. Assessment of the fixation stiffness of some femoral stems of different designs.
Sakai R; Kanai N; Itoman M; Mabuchi K
Clin Biomech (Bristol, Avon); 2006 May; 21(4):370-8. PubMed ID: 16431001
[TBL] [Abstract][Full Text] [Related]
17. Stability of a cannulated screw versus a Kirschner wire for the proximal crescentic osteotomy of the first metatarsal: a biomechanical study.
Bozkurt M; Tigaran C; Dalstra M; Jensen NC; Linde F
J Foot Ankle Surg; 2004; 43(3):138-43. PubMed ID: 15181429
[TBL] [Abstract][Full Text] [Related]
18. Transfixion wire positioning within the bone: an option to control proximal tibia external fixation stiffness.
Antoci V; Raney EM; Antoci V; Voor MJ; Roberts CS
J Pediatr Orthop; 2006; 26(4):466-70. PubMed ID: 16791063
[TBL] [Abstract][Full Text] [Related]
19. Biomechanical stability of different fixation constructs for ORIF of radial neck fractures.
Capo JT; Svach D; Ahsgar J; Orillaza NS; Sabatino CT
Orthopedics; 2008 Oct; 31(10):. PubMed ID: 19226014
[TBL] [Abstract][Full Text] [Related]
20. Biomechanical comparison of extended trochanteric osteotomy and slot osteotomy for femoral component revision in total hip arthroplasty.
Khanna G; Bourgeault CA; Kyle RF
Clin Biomech (Bristol, Avon); 2007 Jun; 22(5):599-602. PubMed ID: 17350150
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]